(TILES)
HD
HD
HD
HD
AB
770 720 720 770
ID
O
Kitchen/ Kitchen/
VO
Foyer Foyer
HD
VE
B
D
SERVICES SERVICES
2100
Dining Dining
870
DUCT DUCT WO WO
REF REF
VO
MW MW
ID
UNIT BLOCK B - OVERALL
(POLISHED PAN PAN (POLISHED
S.A. S.A.
AB
CONCRETE) 17 17 CONCRETE)
O
Kitchen/ Kitchen/ Foyer
VE
16 16
24360
15 15 SERVICES SERVICES
7590
1800 14 14 DUCT Dining Dining DUCT
FG
1800
13 13 (POLISHED PAN PAN (POLISHED
UNIT 19 UNIT 18
S.A. 17 17 S.A.
12 12 CONCRETE) CONCRETE)
11 11 16 16
10 10 15 15 SERVICES
DUCT
4490
09 09 14 14
4260
GROUND LEVEL CEILING HEIGHTS TO
Living 08 08
Living 13 13 (POLISHED PAN PAN (POLISHED
UNIT 17 UNIT 16
S.A. S.A.
07 07 12 12 CONCRETE) 17 17 CONCRETE) BE 2700mm UNLESS STATED OTHERWISE
06 06 11 11 16 16 TOTAL STORAGE ACHIEVED FOR EACH
15 15
05 05 10 10 UNIT 12.68m2
09 09 14 14
04 04 ALL GLAZING WITHIN 10m FIRE ZONE
Living 08 08
Living 13 13
00 01 02 03
UP
03 02 01 00
UP
07
06
07
06
UNIT 15 12
11
12
11
UNIT 14 TOS.A.
BE IN ACCORDANCE WITH THE
REQUIREMENTS OF A.S. 3959
05 05 10 10 AIR CONDITIONING TO
04 04 09 09 BUILDERS/MANUFACTURERS DETAILS
2400
2980
2400
2980
Living Living
2400
1540
2400
1540
70
70
70
08 08 EXPOSED MULLIONS TO HAVE COVER
M M 00 01 02 03 03 02 01 00
07 07
MSD FG FG MSD UP UP PLATES TO MATCH WINDOW FRAMES
06 06
05 05
2100 HIGH INTERNAL DOORS PLAIN
Outdoor GARDEN BED GARDEN BED Outdoor 04 04 FINISH UNLESS NOMINATED OTHERWISE
2400
2980
2400
2980
2400
1540
2400
1540
FRAMELESS MIRRORS TO ALL
Living Living MSD
M M
MSD
00 01 02 03
UP
03 02 01 00
UP
BATHROOMS
(POLISHED CONCRETE - (POLISHED CONCRETE - FG FG
WITH NON-SLIP COATING) WITH NON-SLIP COATING) SQ SET CEILINGS THROUGHOUT
ALL WINDOWS TO BE SITE MEASURED
Outdoor GARDEN BED GARDEN BED Outdoor
2400
2980
2400
2980
2400
1540
2400
1540
EXTENT OF MASTER EXTENT OF MASTER General Notes
BEDROOM ABOVE BEDROOM ABOVE
Living Living MSD
M M
MSD
Do not scale dimensions.
(POLISHED CONCRETE - (POLISHED CONCRETE - FG FG Check and verify all dimensions prior to commencement.
WITH NON-SLIP COATING) WITH NON-SLIP COATING) Removable door to WC.
All windows to be verified against floor plans and elevations
Outdoor GARDEN BED GARDEN BED Outdoor by contractor. Discrepancies are to be reported to the
190 1400 70 3140 190 EXTENT OF MASTER EXTENT OF MASTER designer prior to commencement.
BEDROOM ABOVE BEDROOM ABOVE
Living Living All work to compy with the BCA, these drawings and all other
70 70 (POLISHED CONCRETE - (POLISHED CONCRETE -
relevant technical
literature for this wind category. These plans to be read in
190 1400 1570 1500 190 WITH NON-SLIP COATING) WITH NON-SLIP COATING) conjunction with engineers report
Gr. Floor Areas for Units 08 -19 Outdoor
Engineering Notes
(Excluding Party Walls) EXTENT OF MASTER EXTENT OF MASTER
190 170 3840 600 BEDROOM ABOVE BEDROOM ABOVE
Living
Refer to Engineers details for:
Footings, Slab, Tiedown, Bracing, Framing Schedule, Floor
Living 43.4m2 (POLISHED CONCRETE
Construction,
WITH NON-SLIP
- framing and Truss details, Wind Category,
Roof
COATING)
Pool, Retaining Walls
190 4610 190
Carport 18.5m2 EXTENT OF MASTER
To comply with the requirements of the local authority
Plumbing And drainage
BEDROOM ABOVE
Entry 5.0m2
Outdoor Living 9.6m2
A NOTE: GROSS FLOOR AREA CALCULATIONS UNIT BLOCK B
Total 76.5m2 ON 'TABLE OF CONTENTS + SITE PLAN' SHEET 1
Client.
Canto Holdings P/L Ground Level Floor Plan Part A Dwg No. 4073 DEVELOPMENT APPLICATION
Lot 4 Hofmann Drive
© Pazcot Pty Ltd 2011
NOOSAVILLE Builder. J. & G. KNOWLES & ASSOCIATES (07) 3341 2592 Drawn JTL Scale 1:100 Date 28/11/2011 Issue A Sheet 8/28
www.reitsma.com.au P: 07 54916834 PO Box 3515 Caloundra QLD 4551 Pazcot Pty Ltd. ABN 48 010 681 802 Lic. No. 65652.Lic. under QBSA Act 1991 BDAQ Member. Trading as Reitsma and Associates
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 Report/Plans - MCU11/0254Related documentApplication case desk ↗
About this file
- File size
- 41.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.