UP
UNIT 09 UNIT 08
06 06 600
BUILDERS/MANUFACTURERS DETAILS
AW
DIVIDING WALLS TO BE
DIVIDING WALLS TO BE
10 10 950
Bed 1 05 05
Bed 1 EXPOSED MULLIONS TO HAVE COVER
ROBE
ROBE
2100 09 09 2100
04 04
D
D
2510 2510
PLATES TO MATCH WINDOW FRAMES
1630
1540
1630
1540
(CARPET) (CARPET)
1800
MINIMUM 60/60/60 FRL AND WITH
MINIMUM 60/60/60 FRL AND WITH
08 08
01 02 03 03 02 01
2100 HIGH INTERNAL DOORS PLAIN
CONSTRUCTED TO ACHIEVE A
CONSTRUCTED TO ACHIEVE A
07 07 600
AW
A MINIMUM Rw50 RATING.
A MINIMUM Rw50 RATING.
FG FG 950
STAIRS UP
STAIRS UP
06 06 FINISH UNLESS NOMINATED OTHERWISE
1100
3000
1100
3000
DIVIDING WALLS TO BE
DIVIDING WALLS TO BE
SW
M M
SW
Bed 1 05
04
05
04
Bed 1 FRAMELESS MIRRORS TO ALL
BATHROOMS
1630
1540
1630
1540
(CARPET) (CARPET)
1800
1800
600
AW
01 02 03 03 02 01 950 SQ SET CEILINGS THROUGHOUT
POWDERCOATED ALUMINIUM POWDERCOATED ALUMINIUM FG FG
ALL WINDOWS TO BE SITE MEASURED
1100
3000
1100
3000
HOOD SURROUND HOOD SURROUND
M M
600 General Notes
AW
SW SW
1630
1540
1630
1540
1800
1800
950 Do not scale dimensions.
Check and verify all dimensions prior to commencement.
Removable door to WC.
'C' CHANNEL STEEL BEAM 'C' CHANNEL STEEL BEAM POWDERCOATED ALUMINIUM POWDERCOATED ALUMINIUM FG FG All windows to be verified against floor plans and elevations
1100
3000
1100
3000
TO ENGINEERS DETAILS TO ENGINEERS DETAILS HOOD SURROUND HOOD SURROUND by contractor. Discrepancies are to be reported to the
M M designer prior to commencement.
SW SW All work to compy with the BCA, these drawings and all other
1800
1800
relevant technical
literature for this wind category. These plans to be read in
POWDERCOATED ALUMINIUM POWDERCOATED ALUMINIUM conjunction with engineers report
'C' CHANNEL STEEL BEAM 'C' CHANNEL STEEL BEAM
TO ENGINEERS DETAILS TO ENGINEERS DETAILS HOOD SURROUND HOOD SURROUND
Engineering Notes
Refer to Engineers details for:
Footings, Slab, Tiedown, Bracing, Framing Schedule, Floor
57790 Construction, Roof framing and Truss details, Wind Category,
Pool, Retaining Walls
UNIT BLOCK B - OVERALL 'C' CHANNEL STEEL BEAM 'C' CHANNEL STEEL BEAM
TO ENGINEERS DETAILS TO ENGINEERS DETAILS Plumbing And drainage
To comply with the requirements of the local authority
A NOTE: GROSS FLOOR AREA CALCULATIONS
ON 'TABLE OF CONTENTS + SITE PLAN' SHEET 1
UNIT BLOCK B
Client.
Canto Holdings P/L First Level Floor Plan Part B Dwg No. 4073
DEVELOPMENT APPLICATION
Lot 4 Hofmann Drive
© Pazcot Pty Ltd 2011
NOOSAVILLE Builder. J. & G. KNOWLES & ASSOCIATES (07) 3341 2592 Drawn JTL Scale 1:100 Date 28/11/2011 Issue A Sheet 11/28
www.reitsma.com.au P: 07 54916834 PO Box 3515 Caloundra QLD 4551 Pazcot Pty Ltd. ABN 48 010 681 802 Lic. No. 65652.Lic. under QBSA Act 1991 BDAQ Member. Trading as Reitsma and Associates
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 Report/Plans - MCU11/0254Related documentApplication case desk ↗
About this file
- File size
- 41.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.