C WINDOW AND DOOR LEGEND
FG FIXED GLASS WINDOW
28190 DH DOUBLE HUNG WINDOW
01 'C' CHANNEL STEEL BEAM
UNIT BLOCK D - OVERALL
'C' CHANNEL STEEL BEAM
190 4610 02 190 3810 190 LW GLASS LOUVRE WINDOW
190 4610 190 TO ENGINEERS DETAILS TO ENGINEERS DETAILS
AW AWNING WINDOW
SW GLASS SLIDING WINDOW
1400 70 3140 M MULLION AND COVERPLATE
600
600
600
'C' CHANNEL STEEL BEAM 'C' CHANNEL STEEL BEAM RD RD RD D DOOR CUPBOARD/ROBE ETC.
TO ENGINEERS DETAILS TO ENGINEERS DETAILS
Gr. Floor Areas for Unit 26 CS CAVITY SLIDING DOOR
2400
3000
3000
2400
3000
2400
HD HINGED DOOR
(Excluding Party Walls)
P'COATED P'COATED MSD MULTI TRACK GLASS SLIDING DOOR
600
600
P'COATED
RD RD BATTENED
SCREEN GATE
BATTENED
SCREEN GATE
BATTENED Living 46.6m2 RD ROLLER DOOR
SCREEN GATE ALL WINDOW AND DOOR SIZES AND LOCATION
Carport 18.5m2
2400
3000
3000
2400
TO BE CONFIRMED ON SITE BY BUILDER/CLIENT
PRIOR TO CONSTRUCTION
2000
P'COATED
BATTENED
P'COATED
BATTENED GATE GATE GATE Entry 5.0m2
SCREEN GATE SCREEN GATE
Outdoor Living 7.8m2
5760
Carport Carport Carport
MINIMUM 60/60/60 FRL AND WITH
MINIMUM 60/60/60 FRL AND WITH
Patio 9.8m2
GARDEN BED
GARDEN BED
GARDEN BED
CONSTRUCTED TO ACHIEVE A
CONSTRUCTED TO ACHIEVE A
GATE GATE (POLISHED CONCRETE -
(POLISHED CONCRETE - (POLISHED CONCRETE -
A MINIMUM Rw50 RATING.
A MINIMUM Rw50 RATING.
WITH NON-SLIP COATING)
Total 87.7m2
5760
5760
WITH NON-SLIP COATING) WITH NON-SLIP COATING)
DIVIDING WALLS TO BE
DIVIDING WALLS TO BE
Carport Carport
MINIMUM 60/60/60 FRL AND WITH
MINIMUM 60/60/60 FRL AND WITH
N
GARDEN BED
GARDEN BED
CONSTRUCTED TO ACHIEVE A
CONSTRUCTED TO ACHIEVE A
(POLISHED CONCRETE - (POLISHED CONCRETE -
A MINIMUM Rw50 RATING.
A MINIMUM Rw50 RATING.
WITH NON-SLIP COATING) WITH NON-SLIP COATING)
DIVIDING WALLS TO BE
DIVIDING WALLS TO BE
FG FG FG FG FG
4360
Entry
D D D
Entry LW Entry
600
1570
600
1570
600
1570
600
2660
600
1200
M M M M
2100
1240
2100
1240
2100
1240
70
DP DP LW DP LW
70
WM WM WM
2100
450
2100
450
2100
450
790
STORAGE STORAGE STORAGE
FG FG HD DRY DRY HD DRY HD
D D
Entry LW Entry
70
70
790 70
2100
2100
2100
600
1570
600
1570
M M
2100
1240
2100
1240
870
AB 870
870
Ldy. W.C. W.C.2100 Ldy.2100 W.C.2100 Ldy.2100
940
DP DP
VO
VE
LW
O
ID
UNIT 26
2100 (TILES) 2100 (TILES) (TILES)
HD
HD
HD
HD
HD
HD
WM WM
AB
2100
450
2100
450
770 720 720 770 720 770
Foyer
ID
STORAGE STORAGE
O
70
DRY DRY
VO
1800
Foyer Foyer
HD HD
VE
70
1670 70
4020
2100
2100
Living
870
AB 870
WO WO
Ldy. W.C. W.C.2100 Ldy.2100 REF REF STAIRS UP
VO
VE
940
MW MW
940
O
UNIT BLOCK D - OVERALL
ID
2100 (TILES) 2100 (TILES)
HD
HD
HD
HD
08 07 06 05 04 03 02 01 00
AB
770 720 720 770
700 70
S.A.
ID
O
Kitchen/ Kitchen/
70
VO
Foyer Foyer
VE
3300
19560
FG
800 09
SERVICES SERVICES (POLISHED
940
Dining Dining
70
WO WO
UNIT 30 - OVERALL
DUCT DUCT CONCRETE)
REF MW MW REF PAN REF
18360
M
Kitchen/ Kitchen/ Kitchen/
2400
3120
70
2400
LW
SERVICES SERVICES
POWDERCOATED DUCT Dining Dining DUCT
Dining
600
2700
UB
B
D
3330
ALUMINIUM BLADE MSD
(POLISHED PAN PAN (POLISHED
S.A. 17 17 S.A. (POLISHED
CONCRETE) CONCRETE)
16 16 CONCRETE)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 Report/Plans - MCU11/0254Related documentApplication case desk ↗
About this file
- File size
- 41.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.