                        CUSTOM FOLDED METAL GUTTER
                        FC LINED
                        RAKED SOFFIT
                        POWDERCOATED ALUMINIUM HOOD




                                                                                                                                600


                                                                                                                                             TO FINISHED CEILING HEIGHT
                        10mm PLASTERBOARD CEILING

                        PAINTED FC SHEETING WITH 40x20mm FC




                                                                                                                                          2400
                        BATTENS OVER @ 300CTRS (DARK COLOUR)
                                                                                                                                                                                Bed 2
                        BOX GUTTER TO HYDRAULIC
                        ENGINEERS DETAILS




                                                                                                                                1500
                        5° PITCH
                        TRIMDEK ROOF
                        'C' CHANNEL STEEL BEAM TO
                        ENGINEERS DETAILS
                        First Level R.L. 8.000                                                                                 (CARPET OVER)



                        OPEN THROUGH TO CARPORT

                        RAKED CEILING TO CARPORT
                        (FC LINED)




                                                                                                                                                                                        TO FINISHED CEILING HEIGHT
                        19mm PARTICLE-BOARD FLOORING
                        BEARERS & FLOOR JOISTS REFER TO
                        ENGINEER'S TIMBER FLOOR LAYOUT PLAN




                                                                                                                                                                                    2700
                                                                         Carport                                                Storage                                   W.C                                          Kitchen
                                                                                                                                                                                                                     (TO FUTURE DETAIL)
                        REINFORCED CONCRETE
                        TILT UP PANEL PARTY
                        WALL (CLEAR SEALED)

                        ROLLER DOOR TO CARPORT


                        R. C. SLAB-REFER ENGINEER'S DETAILS
                        Ground Level R.L. 4.950                                    (POLISHED CONCRETE WITH NO-SLIP COATING)                                               (TILES)                                      (POLISHED CONCRETE)




                        FOOTINGS-REFER
                        ENGINEER'S DETAILS


                        MOISTURE BARRIER


                        SANDBED




                                                                                                                                                                                                                                                              UNIT BLOCK D
                                                               Client.
                                                               Canto Holdings P/L                                                                                                   General Section 01a                                                        Dwg No. 4073
                                                                                                                                                                                                                                                                         DEVELOPMENT APPLICATION
                                                               Lot 4 Hofmann Drive
© Pazcot Pty Ltd 2011
                                                               NOOSAVILLE                             Builder. J. & G. KNOWLES & ASSOCIATES (07) 3341 2592                                                                          Drawn JTL Scale 1:50   Date 28/11/2011 Issue A     Sheet 23/28
                                                                                                            www.reitsma.com.au P: 07 54916834 PO Box 3515 Caloundra QLD 4551 Pazcot Pty Ltd. ABN 48 010 681 802 Lic. No. 65652.Lic. under QBSA Act 1991 BDAQ Member. Trading as Reitsma and Associates

Used in these records

About this file

File size
41.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Application part 2 Report_Plans - MCU11_0254.pdf · 41.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.