5. Public Protection Controls and Traffic Management
Residual
Rating
Proposed Controls
Initial
HOC
Risk
Risk
Activity Hazard Responsible Person
(1/Elimination 2/Substitution 3/Isolation 4/Engineering 5/Administration 6/PPE)
Implementation Unauthorised access HIGH 1 • Temporary fencing will be erected as per manufacturers / suppliers’ specifications. M Site Management
• Gates to be locked at all times after hours.
• Site amenities (Site Office and Lunchroom) are locked each day.
• All building entry point to be secured and locked at the conclusion of each day.
Unauthorised road / HIGH 5 Written approval will be obtained from the relevant authority to close adjoining areas when excluding members L Site Management
footpath closures of the public.
Any controls imposed by the authority will be fully implemented and monitored during the project.
Injuries to the public HIGH 3 Hoardings erected on site will: M Project Management
• be able to withstand a horizontal force of- Site Management
2 2
– 500 N/m applied over 1m at the top of the hoarding midway between any two posts without
deforming permanently &
– 950 N/m2 applied over 1500mm2 at any point on the hoarding without fully penetrating the hoarding.
• only have small gaps that are necessary to minimize wind resistance; and
• extend to the gantry’s overhead platform (if it is part of a gantry).
Injuries to the public HIGH 5 During installation, extension or reduction of catch platforms or screening, appropriate measures (i.e. such as M Site Management
closing the adjoining area) will be taken to ensure that a falling object cannot injure a member of the public in Contract Partner
the adjoining area.
Falling objects HIGH 3 For QLD Around the perimeter of the site based on the angle made between: M Project Management
• the horizontal and Site Management
• an imaginary line drawn between the closest point where the public have access, to the highest point on HSE Advisor with
the building/structure where work is to be done: BSBWHS414 OHS Cert
4
The fencing will be:
• (< 15o) ☐ barricade or hoarding at least 900mm high.
• (15o – 30o) ☐ A hoarding at least 1800mm high.
• (30o – 75o) ☐ a hoarding at least 1800mm high that is fully sheeted with timber, plywood, metal, or
sturdy synthetic sheets.
• (75o or more) ☐ a hoarding at least 1800mm high that is fully sheeted with timber, plywood, metal, or
sturdy synthetic sheets, AND one of the following:
– a gantry (or overhead protective structure), (incorporating the hoarding), or
Project Hazard/Risk Assessment / Page 20 of 160
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
STP24-0253 Application for Operational Works Fire Trail - 80 Cooyar Street Noosa Heads.pdfRelated documentApplication case desk ↗
About this file
- File size
- 58.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.