STP24-0253 Application for Operational Works Fire Trail - 80 Cooyar Street Noosa Heads · OPW24/0125
Very large file (58.9 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Original PDF page 378, section 1. The text section number identifies this passage in the reader.
Residual
Proposed Controls Responsible
Rating
Initial
Risk
Risk
HC
Activity Hazard Person
(1/Elimination 2/Substitution 3/Isolation 4/Engineering 5/Administration 6/PPE)
Site
HIGH 5 Workers shall complete a confined space entry permit, that has been reviewed and approved prior to setting up for the confined Management
space entry
Contract Partner
Site
HIGH 5 Employers who’s work activities involves confined space entry shall provide a SWMS for review and approval. The SWMS shall Management
include the control measures and rescue plan to be implemented in the event a person or people need to be rescued. SWMS
indicates the minimum number of persons involved to be three. Contract Partner
Site
HIGH 5 Workers involved in the rescue have provided evidence of a current Confined Space Entry qualification - RIIWHS202E - Enter and Management
work in Confined Spaces, MSMPER200 - Work in Accordance with an Issued Permit, MSMWHS217 - Gas Test Atmospheres and
MSMWHS216 - Operate Breathing Apparatus Contract Partner
Site
Use of Specific No means of EXTREME 3 A gas monitor shall be readily available, used to test the atmosphere prior to each entry and monitor during the activity. The gas Management
Equipment testing the monitor shall display a current calibration sticker and be fully operational.
atmosphere Contract Partner
Site
No means of EXTREME 3 Access to a fully functional ventilation system powered by a reliable power source shall be set-up prior to any person accessing the Management
purging the confined space. It shall be turned on if necessary.
space Contract Partner
Site
No access to EXTREME 3 Should it be identified in the confined space entry permit a need for BA equipment the equipment shall be sourced from a reputable Management
breathing service provide accompanied by service and calibration certificates. The equipment shall be tested before any person enters the
apparatus space. Contract Partner
Site
No means EXTREME 3 A fully compliant retrieval system shall be set-up prior to any person accessing the confined space. Management
available to
recue person/s Contract Partner
from a confined
space Site
EXTREME 5 There shall be a minimum of two standby personnel to initiate a rescue when necessary. Management
Contract Partner
Site
No means of EXTREME 5 A standby person shall have available a means of communication so in the event of an emergency the relevant emergency services Management
communication can be contacted immediately
Contract Partner
Project Hazard/Risk Assessment / Page 136 of 160
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
STP24-0253 Application for Operational Works Fire Trail - 80 Cooyar Street Noosa Heads.pdfRelated documentApplication case desk ↗
About this file
- File size
- 58.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.