                                                                                                                                                                                                        Residual
                                                                                                                       Proposed Controls                                                                             Responsible




                                        Rating
                                        Initial
                                         Risk




                                                                                                                                                                                                          Risk
                                                      HC
     Activity            Hazard                                                                                                                                                                                        Person
                                                                                            (1/Elimination 2/Substitution 3/Isolation 4/Engineering 5/Administration 6/PPE)


                     Inadequate                            - Emergency lighting will be in accordance with AS/NZS 3012 requiring a minimum of 20 lux.                                                              Site
                                       EXTREME    5                                                                                                                                                                Management
                     temporary or                          - Sufficient battery powered lighting (minimum 1 hour capacity) will be installed in stairways, passageways and adjacent to
                     emergency                                 switchboards to allow safe access to and egress from the area if there is insufficient natural “lighting” for the case of                           Contract Partner
                     light levels                              emergency.
                                                           - Emergency Lighting shall be verified by measurement using an appropriate light level meter with records of the test provided to
                                                               Woollam.
                                                           Emergency Lighting is to be provided in designated access and egress paths and directly above and in front of switchboards where
                                                           natural lighting requirements cannot be met using natural lighting.

                                                                                                                                                                                                                   Site
Use of specific      Alarm system      HIGH       5        Ensure emergency lighting is regularly checked by electrical contractor and tested in Evacuation drill.                                                 Management
equipment            (not power
                     reliant)                                                                                                                                                                                      Contract Partner
                     emergency
                     lighting in
                     corridors and
                     common areas

                                                                                                                                                                                                                   Site
List activities in   Workers           EXTREME    5        All inducted personnel on the project shall be introduced to the project specific Emergency Preparedness and Response Plan.                             Management
procedure e.g.       unfamiliar with                       Workers shall be informed of the Emergency Control Organisation team members and the location of displayed emergency contact
Evacuation to        emergency                             details.                                                                                                                                                Contract
route, isolate       procedures and                                                                                                                                                                                Partners
specific hazard,     processes
prevent spread
of contaminants      Workers           EXTREME    5        All inducted personnel on the project shall be introduced to the project specific Emergency Preparedness and Response Plan.                             Site
where possible       unaware of                            Workers shall be informed of the Emergency Control Organisation team members and the location of displayed emergency contact                            Management
                     hazard                                details.                                                                                                                                                Contract
                                                                                                                                                                                                                   Partners

                                                                                                                                                                                                                   Site
                     Workers not       EXTREME    5        All inducted personnel shall be informed of the emergency evacuation procedure and processes including location of emergency                            Management
                     familiar with                         assembly point and pedestrian routes.
                     location of                                                                                                                                                                                   Contract
                     assembly                                                                                                                                                                                      Partner
                     point/s or
                     pedestrian
                     traffic routes


     19.20           Roof Rescue

                                                                                                                                                     Project Hazard/Risk Assessment / Page 150 of 160

Used in these records

About this file

File size
58.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

STP24-0253 Application for Operational Works Fire Trail - 80 Cooyar Street Noosa Heads.pdf · 58.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.