                                                                                                          ABBREVIATION LEGEND
                                                                                                                                                                                  NOTES
                                                                                                                                                                                  -              GROUND LEVELS, FINISHED FLOOR LEVELS, SITE WORKS AND RETAINING ARE INDICATIVE ONLY
                                                                                                          B1    BATH TYPE 1                                                                      AND ARE TO BE CONFIRMED ON SITE PRIOR TO CONSTRUCTION. SITE PLANS ARE TO BE READ IN
                                                                                                          BAL1 BALUSTRADE TYPE 1                                                                 CONJUNCTION WITH ANY SURVEY/ENGINEERING PLANS AVAILABLE.
                                                                                                          BAL2 BALUSTRADE TYPE 2
                                                                                                          CFF1 CLADDING FEATURE FINISH TO EXISTING BLOCK                          -              ALL DIMENSIONS ARE TO BE CHECKED WITH EXISTING AND PROPOSED SITE CONDITIONS.
                                                                                                          CT1 600 ELECTRIC COOKTOP                                                -              ALL DIMENSIONS TO BE CONFIRMED ON SITE PRIOR TO CONSTRUCTION.
                                                                                                          CT2 COOKTOP TYPE 2                                                                     BUILDER TO NOTIFY ANY DISCREPANCIES TO ARCHITECT FOR CLARIFICATION PRIOR TO
                                                                                                          DGPO DOUBLE GENERAL POWER OUTLET                                                       COMMENCING/CONTINUING WORKS
                                                                                                          DRY DRYER
                                                                                                          DP    DOWNPIPE                                                          -              WRITTEN DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
                                                                                                          DW    DISHWASHER
                                                                                                          EG1 EXISTING COLORBOND FASCIA GUTTER                                    -              NO VARIATION MAY BE MADE TO THESE DRAWINGS WITHOUT THE PRIOR APPROVAL OF THE
                                                                                                          EX1 EXHAUST FAN TYPE 1                                                                 ARCHITECT
                                                                                                          FB    FLOOR BOX
                                                                                                          FCS1 FIBRE CEMENT SOFFIT                                                -              REFER TO ENGINEERS DESIGN, DOCUMENTATION AND CALCULATION FOR DETAILS ON SLAB,
                                                                                                          FW1 FLOOR WASTE                                                                        FOOTINGS, STRUCTURE, RETAINING WALLS, FINISHED FLOOR LEVELS, SITEWORKS AND
                                                                                                          GA1 GATE TYPE 1                                                                        STORMWATER DETAILS.
                                                                                                          GPO GENERAL POWER OUTLET
                                                                                                          GD1 GRATED DRAIN EVERHARD EASY DRAIN                                    -              THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL OTHER DRAWINGS SHEETS,
                                                                                                                w/ GAL STEEL GRATE                                                               CONSULTANTS DRAWINGS, DOCUMENTS, SCHEDULES AND SPECIFICATIONS (AS APPLICABLE).
                                                                                                          GD2 GRATED DRAIN AQUABOCCI S66 CHANNEL
                                                                                                                DRAIN-SINGLE RUN-GT SILVER                                        -              THE BUILDER AND SUBCONTRACTOR SHALL ENSURE THAT ALL STORMWATER DRAINS, SEWER
                                                                                                          HB    HAND BASIN                                                                       PIPES AND THE LIKE ARE LOCATED AT A SUFFICIENT DISTANCE FROM ANY BUILDINGS FOOTING
                                                                                                          HR1 HANDRAIL TYPE 1                                                                    AND/OR SLAB EDGE BEAMS SO AS TO PREVENT GENERAL MOISTURE PENETRATION,
                                                                                                          HC1 HORIZONTAL CLADDING TYPE 1                                                         DAMPNESS, WEAKENING & UNDERMINING OF ANY BUILDING AND ITS FOOTING SYSTEM.
                                                                                                          HC2 HORIZONTAL CLADDING TYPE 2
                                                                                                          HWS HOT WATER SYSTEM                                                    -              LOCATION OF ALL EXISTING ONSITE SERVICES TO BE CONFIRMED ONSITE PRIOR TO
                                                                                                          LWC1 LIGHT WEIGHT CLADDING TYPE 1                                                      CONSTRUCTION
                                                                                                          MB    METER BOARD
                                                                                                          MRS1 METAL ROOF SHEETING TYPE 1                                         -              ALL TIMBER FRAMING, IN ACCORDANCE WITH AS1684 AND ENGINEERS REQUIREMENTS.
                                                                                                          OHC OVERHEAD CUPBOARD
                                                                                                          P     PENDANT LIGHT                                                     -              ALL WET AREAS ARE TO BE WATERPROOFED THROUGHOUT WITH A PROPRIETARY
                                                                                                          PB1 PLASTER BOARD - STANDARD                                                           WATERPROOFING SYSTEM INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS
                                                                                                          PB2 PLASTER BOARD - WET AREAS                                                          RECOMMENDATIONS. PROVIDE INSULATION IN ACCORDANCE WITH PART 3.12 OF THE BCA.
                                                                                                          PF1 POOL FENCE TYPE 1
                                                                                                          PV1 PAVERS TYPE 1                                                       -              BUILDING WORKS IN ACCORDANCE WITH BCA ENVIRONMENTAL GUIDELINES.
                                                                                                          RBW1 RENDERED BLOCK WORK FINISH 1
                                                                                                          RBW2 RENDERED BLOCK WORK FINISH 2                                       -              ALL GLAZING SHALL COMPLY WITH AS1288. (DOORS AND WINDOWS SUBJECT TO HUMAN
                                                                                                          REF REFRIGERATOR                                                                       IMPACT, GLAZING TYPE AND THICKNESS 6.38MM GRADE A LAMINATED GLASS)
                                                                                                          RF1 RENDERED FINISH TYPE 1
                                                                                                          S     SMOKE ALARM                                                       -              THE PROVISION OF ENERGY EFFICIENT LIGHTING TO COMPLY WITH EITHER THE QUEENSLAND
                                                                                                          S1    SINK TYPE 1                                                                      DEVELOPMENT CODE METHODOLOGY FOR 80% ENERGY EFFICIENT LIGHTING OR THE BCA
                                                                                                          S2    SINK TYPE 2                                                                      METHODOLOGY BASED ON WATTS PER SQUARE METER.
                                                                                                          SCR1 SCREEN TYPE 1
                                                                                                          SCR2 SCREEN TYPE 2                                                      -              ALL WORK MUST COMPLY WITH THE BUILDING CODE OF AUSTRALIA AND AUSTRALIAN
                                                                                                          SCR3 SCREEN TYPE 3                                                                     STANDARDS, AND ALL OTHER RELEVANT BY LAWS AND AUTHORITIES. NO WORK SHALL BE
                                                                                                          SHRS1 FRAMELESS GLASS SHOWER SCREEN TYPE 1                                             UNDERTAKEN PRIOR TO APPROVAL BY A REGISTERED CERTIFIER.
                                                                                                          TC1 TIMBER CEILING LINING
                                                                                                          TD1 TIMBER DECKING TYPE 1                                               -              NO FOOTING, OR WALL TO ENCROACH THE TITLE BOUNDARY.
                                                                                                          TF1 TIMBER FLOORING TYPE 1
                                                                                                          TL1 TILE TYPE 1 - EXTERNAL                                              -              DOWNPIPES 90MMØ ZINCALUME U.N.O, ALLOW TO CONNECT TO IN-GROUND STORM WATER
                                                                                                          TL2 TILE TYPE 2 - INTERNAL                                                             DRAINS 150MMØ UPVC, OR 2/90MM DIA. 1:100 MINIMUM GRADE WITH I.O'S AT EACH CHANGE OF
                                                                                                          TL3 TILE TYPE 3 - INTERNAL                                                             DIRECTION AND 6000MM CENTRES. THE PROVISION OF WATER TANKS TO COMPLY WITH
                                                                                                          TRS1 TRANSLUCENT ROOF SHEETING TYPE 1                                                  QUEENSLAND DEVELOPMENT CODE.
                                                                                                          TUB LAUNDRY TUB
                                                                                                          UBO 600w UNDERBENCH ELECTRIC OVEN                                       -              PLUMBING TO BE CARRIED OUT BY A LICENSED PLUMBER AND IN ACCORDANCE WITH THE
                                                                                                          VB    VANITY BASIN                                                                     REQUIREMENT OF LOCAL AUTHORITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
                                                                                                          VTL VERTICAL TIMBER LOUVRES                                                            PERMITS AND APPROVALS. ALL HOT WATER LINES SHALL BE FULLY INSULATED. SANITARY
                                                                                                          VC1 VERTICAL CLADDING TYPE 1                                                           PLUMBING SHALL BE CONNECTED TO EXISTING SYSTEM WITH MATERIALS APPROVED BY THE
                                                                                                          VC2 VERTICAL CLADDING TYPE 2                                                           LOCAL AUTHORITY.
                                                                                                          WC1 TOILET TYPE 1
                                                                                                          WM WASHING MACHINE                                                      -              TERMITE PROTECTION TO BE CARRIED OUT IN ACCORDANCE WITH AS3660 AND THE
                                                                                                                                                                                                 REQUIREMENTS OF THE BUILDING CODE OF AUSTRALIA PART 3.1.3..

                                                                                                                                                                                  -              ALL DOMESTIC HOT WATER TO BASINS, SHOWERS AND BATHS TO HAVE MAXIMUM
                                                                                                                                                                                                 TEMPERATURE OF 50°C. ALLOW TO SUPPLY AND INSTALL TEMPERING VALVES WHERE
                                                                                                                                                                                                 REQUIRED, AS NOMINATED IN THE BCA AND RELEVANT STANDARDS.

                                                                                                                                                                                  -              SUPPLY AND INSTALL APPROVED SMOKE DETECTORS IN ACCORDANCE WITH 'NCC VOLUME TWO,
                                                                                                                                                                                                 PART 3.7.2 - SMOKE ALARMS' AND ALL QFES REQUIREMENTS. ALARMS TO BE INTERCONNECTED
                                                                                                                                                                                                 TO ACTIVATE AT THE SAME TIME. SMOKE ALARMS MUST BE HARDWIRED TO MAINS POWER WITH
                                                                                                                                                                                                 A SECONDARY POWER SOURCE. SMOKE ALARMS MUST BE PHOTOELECTRIC AND NOT CONTAIN
                                                                                                                                                                                                 AN IONISATION SENSOR.




                                                                                                                    CLIENT                                                ISSUE   DATE        DESCRIPTION           DRAWN   DRAWING TITLE                   PROJECT NO
    1/4A ARCADIA WALK
        Noosa Heads
                               This drawing is copyright and the property of the author and must not be
                               retained, copied or used without the authority of the author. Larger                 Mark + Kylie Wisken           PROPOSED ALTERATIONS     A      15.03.19   prelim sketch                  GENERAL NOTES & DRAWING         18005
         4567 QLD                                                                                                                                                          B      12.04.19   PRELIM TENDER
                               scale drawings and written dimensions take preference.
                               Do not scale from drawings.                                                                                        and ADDITIONS                                                             SCHEDULE                        STAGE
www.epocharchitecture.com.au   All dimensions to be checked on site prior to commencement of work. All
                               discrepancies to be brought to the attention of the author.
                                                                                                                                                                                                                                                            CD
                                                                                                                    1 / 512 DAVID LOW WAY         1 / 512 DAVID LOW WAY
       0420 584 943
                                                                                                                    MARCUS DUNES                  MARCUS DUNES                                                              SCALE                           DRAWING NO       REVISION

                                                                                                                                                                                                                            1 : 100         @A3             001                 B

Used in these records

About this file

File size
6.2 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Plans.pdf · 6.2 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.