ABBREVIATION LEGEND
NOTES
- GROUND LEVELS, FINISHED FLOOR LEVELS, SITE WORKS AND RETAINING ARE INDICATIVE ONLY
B1 BATH TYPE 1 AND ARE TO BE CONFIRMED ON SITE PRIOR TO CONSTRUCTION. SITE PLANS ARE TO BE READ IN
BAL1 BALUSTRADE TYPE 1 CONJUNCTION WITH ANY SURVEY/ENGINEERING PLANS AVAILABLE.
BAL2 BALUSTRADE TYPE 2
CFF1 CLADDING FEATURE FINISH TO EXISTING BLOCK - ALL DIMENSIONS ARE TO BE CHECKED WITH EXISTING AND PROPOSED SITE CONDITIONS.
CT1 600 ELECTRIC COOKTOP - ALL DIMENSIONS TO BE CONFIRMED ON SITE PRIOR TO CONSTRUCTION.
CT2 COOKTOP TYPE 2 BUILDER TO NOTIFY ANY DISCREPANCIES TO ARCHITECT FOR CLARIFICATION PRIOR TO
DGPO DOUBLE GENERAL POWER OUTLET COMMENCING/CONTINUING WORKS
DRY DRYER
DP DOWNPIPE - WRITTEN DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
DW DISHWASHER
EG1 EXISTING COLORBOND FASCIA GUTTER - NO VARIATION MAY BE MADE TO THESE DRAWINGS WITHOUT THE PRIOR APPROVAL OF THE
EX1 EXHAUST FAN TYPE 1 ARCHITECT
FB FLOOR BOX
FCS1 FIBRE CEMENT SOFFIT - REFER TO ENGINEERS DESIGN, DOCUMENTATION AND CALCULATION FOR DETAILS ON SLAB,
FW1 FLOOR WASTE FOOTINGS, STRUCTURE, RETAINING WALLS, FINISHED FLOOR LEVELS, SITEWORKS AND
GA1 GATE TYPE 1 STORMWATER DETAILS.
GPO GENERAL POWER OUTLET
GD1 GRATED DRAIN EVERHARD EASY DRAIN - THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL OTHER DRAWINGS SHEETS,
w/ GAL STEEL GRATE CONSULTANTS DRAWINGS, DOCUMENTS, SCHEDULES AND SPECIFICATIONS (AS APPLICABLE).
GD2 GRATED DRAIN AQUABOCCI S66 CHANNEL
DRAIN-SINGLE RUN-GT SILVER - THE BUILDER AND SUBCONTRACTOR SHALL ENSURE THAT ALL STORMWATER DRAINS, SEWER
HB HAND BASIN PIPES AND THE LIKE ARE LOCATED AT A SUFFICIENT DISTANCE FROM ANY BUILDINGS FOOTING
HR1 HANDRAIL TYPE 1 AND/OR SLAB EDGE BEAMS SO AS TO PREVENT GENERAL MOISTURE PENETRATION,
HC1 HORIZONTAL CLADDING TYPE 1 DAMPNESS, WEAKENING & UNDERMINING OF ANY BUILDING AND ITS FOOTING SYSTEM.
HC2 HORIZONTAL CLADDING TYPE 2
HWS HOT WATER SYSTEM - LOCATION OF ALL EXISTING ONSITE SERVICES TO BE CONFIRMED ONSITE PRIOR TO
LWC1 LIGHT WEIGHT CLADDING TYPE 1 CONSTRUCTION
MB METER BOARD
MRS1 METAL ROOF SHEETING TYPE 1 - ALL TIMBER FRAMING, IN ACCORDANCE WITH AS1684 AND ENGINEERS REQUIREMENTS.
OHC OVERHEAD CUPBOARD
P PENDANT LIGHT - ALL WET AREAS ARE TO BE WATERPROOFED THROUGHOUT WITH A PROPRIETARY
PB1 PLASTER BOARD - STANDARD WATERPROOFING SYSTEM INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS
PB2 PLASTER BOARD - WET AREAS RECOMMENDATIONS. PROVIDE INSULATION IN ACCORDANCE WITH PART 3.12 OF THE BCA.
PF1 POOL FENCE TYPE 1
PV1 PAVERS TYPE 1 - BUILDING WORKS IN ACCORDANCE WITH BCA ENVIRONMENTAL GUIDELINES.
RBW1 RENDERED BLOCK WORK FINISH 1
RBW2 RENDERED BLOCK WORK FINISH 2 - ALL GLAZING SHALL COMPLY WITH AS1288. (DOORS AND WINDOWS SUBJECT TO HUMAN
REF REFRIGERATOR IMPACT, GLAZING TYPE AND THICKNESS 6.38MM GRADE A LAMINATED GLASS)
RF1 RENDERED FINISH TYPE 1
S SMOKE ALARM - THE PROVISION OF ENERGY EFFICIENT LIGHTING TO COMPLY WITH EITHER THE QUEENSLAND
S1 SINK TYPE 1 DEVELOPMENT CODE METHODOLOGY FOR 80% ENERGY EFFICIENT LIGHTING OR THE BCA
S2 SINK TYPE 2 METHODOLOGY BASED ON WATTS PER SQUARE METER.
SCR1 SCREEN TYPE 1
SCR2 SCREEN TYPE 2 - ALL WORK MUST COMPLY WITH THE BUILDING CODE OF AUSTRALIA AND AUSTRALIAN
SCR3 SCREEN TYPE 3 STANDARDS, AND ALL OTHER RELEVANT BY LAWS AND AUTHORITIES. NO WORK SHALL BE
SHRS1 FRAMELESS GLASS SHOWER SCREEN TYPE 1 UNDERTAKEN PRIOR TO APPROVAL BY A REGISTERED CERTIFIER.
TC1 TIMBER CEILING LINING
TD1 TIMBER DECKING TYPE 1 - NO FOOTING, OR WALL TO ENCROACH THE TITLE BOUNDARY.
TF1 TIMBER FLOORING TYPE 1
TL1 TILE TYPE 1 - EXTERNAL - DOWNPIPES 90MMØ ZINCALUME U.N.O, ALLOW TO CONNECT TO IN-GROUND STORM WATER
TL2 TILE TYPE 2 - INTERNAL DRAINS 150MMØ UPVC, OR 2/90MM DIA. 1:100 MINIMUM GRADE WITH I.O'S AT EACH CHANGE OF
TL3 TILE TYPE 3 - INTERNAL DIRECTION AND 6000MM CENTRES. THE PROVISION OF WATER TANKS TO COMPLY WITH
TRS1 TRANSLUCENT ROOF SHEETING TYPE 1 QUEENSLAND DEVELOPMENT CODE.
TUB LAUNDRY TUB
UBO 600w UNDERBENCH ELECTRIC OVEN - PLUMBING TO BE CARRIED OUT BY A LICENSED PLUMBER AND IN ACCORDANCE WITH THE
VB VANITY BASIN REQUIREMENT OF LOCAL AUTHORITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
VTL VERTICAL TIMBER LOUVRES PERMITS AND APPROVALS. ALL HOT WATER LINES SHALL BE FULLY INSULATED. SANITARY
VC1 VERTICAL CLADDING TYPE 1 PLUMBING SHALL BE CONNECTED TO EXISTING SYSTEM WITH MATERIALS APPROVED BY THE
VC2 VERTICAL CLADDING TYPE 2 LOCAL AUTHORITY.
WC1 TOILET TYPE 1
WM WASHING MACHINE - TERMITE PROTECTION TO BE CARRIED OUT IN ACCORDANCE WITH AS3660 AND THE
REQUIREMENTS OF THE BUILDING CODE OF AUSTRALIA PART 3.1.3..
- ALL DOMESTIC HOT WATER TO BASINS, SHOWERS AND BATHS TO HAVE MAXIMUM
TEMPERATURE OF 50°C. ALLOW TO SUPPLY AND INSTALL TEMPERING VALVES WHERE
REQUIRED, AS NOMINATED IN THE BCA AND RELEVANT STANDARDS.
- SUPPLY AND INSTALL APPROVED SMOKE DETECTORS IN ACCORDANCE WITH 'NCC VOLUME TWO,
PART 3.7.2 - SMOKE ALARMS' AND ALL QFES REQUIREMENTS. ALARMS TO BE INTERCONNECTED
TO ACTIVATE AT THE SAME TIME. SMOKE ALARMS MUST BE HARDWIRED TO MAINS POWER WITH
A SECONDARY POWER SOURCE. SMOKE ALARMS MUST BE PHOTOELECTRIC AND NOT CONTAIN
AN IONISATION SENSOR.
CLIENT ISSUE DATE DESCRIPTION DRAWN DRAWING TITLE PROJECT NO
1/4A ARCADIA WALK
Noosa Heads
This drawing is copyright and the property of the author and must not be
retained, copied or used without the authority of the author. Larger Mark + Kylie Wisken PROPOSED ALTERATIONS A 15.03.19 prelim sketch GENERAL NOTES & DRAWING 18005
4567 QLD B 12.04.19 PRELIM TENDER
scale drawings and written dimensions take preference.
Do not scale from drawings. and ADDITIONS SCHEDULE STAGE
www.epocharchitecture.com.au All dimensions to be checked on site prior to commencement of work. All
discrepancies to be brought to the attention of the author.
CD
1 / 512 DAVID LOW WAY 1 / 512 DAVID LOW WAY
0420 584 943
MARCUS DUNES MARCUS DUNES SCALE DRAWING NO REVISION
1 : 100 @A3 001 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.