Council archive · source document
08/0110 - MCU - Duplex Dwelling to be assesed against the Superseeded Planning Scheme [As Published] · 132008.110
Proposal Report: Development Application for Material Change of Use for o Duplex Dwelling over Lot 5 RP66617, located at 8 Edward Street, Noosaville Applicants: J Tauschke and § Chang * Do not have harsh skylines and make use of roof pitches, sunhoods and eaves. The building has been well articulated to provide substantial deck and terrace areas. The proposed duplex provides eaves and overhangs along all fagades and the resulting presentation and skyline will be consistent with the urban landscape and roofscape of surrounding development. * Respect the public spaces about the site. The proposal respects existing and future adjoining development and seeks to take advantage of an opportunity to overlook a public car parking area, rather than the private open space of adjoining premises. * Promote the concept of small separate buildings, rather than large single, bulky developments. The stepping of the building fagade, use of different levels and incorporation of horizontal and vertical design elements provides visual interest and variation to the built form. The proposed design seeks to minimise the bulk presented to the road and northern elevation so as to minimise visual impact to Edward Street and Gympie Terrace. The building is of a similar scale and form to other duplex developments that have been approved in the Noosaville area. The Strategic Plan further outlines in section 19.2.1.9 that those sites within the Semi-Detached and Attached Residential designation and the Visitor Accommodation and Services designation, located closest to the Neighbourhood Centre designation will be more intensively developed, with buildings of up to 3 storeys. Design considerations for duplex dwellings are listed in the development provisions of the superseded Noosa Shire Planning Scheme and are assessed in the following section of this report. 6.3. Compliance with Noosa Shire Planning Scheme The subject site is included within the Residential Medium Density zone, the intent of which is to provide for a mix of residential uses including duplex dwellings, multiple dwellings, group housing developments and accommodation buildings with building heights of up to 2 to 3 storeys. The proposal is consistent with the intent of the zone. Section 5.3 of the Planning Scheme provides a number of performance standards for duplex dwellings. The following table summarises the compliance of the proposal against the relevant development provisions: Provision Requirement Proposal Response Compliance 5.3.1.1 Road frontages: Setbacks 6.0 metres — two storeys Minimum 6.0 metres on ground | Second floor (third storey) 10.0 metres = third storey floor and first floor proposes a minimum setback of 7.15 metres (refer below) Rear: 6.0 metres Minimum 6.0 metres v Side: comply with Building Act Minimum 1.5 metres on first and second storeys, minimum 2.0 metres on third storey v 5.3.1.2 The length of wall in any one | Maximum wall length in any Length of Wall plane is less than 15 metres one plane is 12 metres v 5.3.1.3 Car parking to be integrated | Garages are setback from the Car parking with line and plane of the | building fagade v duplex dwelling where covered car parking is proposed between the building fagade and the road frontage 1 space per dwelling unit plus | 2 car spaces are provided one space for visitor car | within enclosed garages for parking each dwelling unit v 222 martoo consulting - Tawn Planning Consultants
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0110 - MCU - Duplex Dwelling to be assesed against the Superseeded Planning Scheme [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.