DEVELOPMENT APPLICATION FOR MCU — DUPLEX DWELLING 7 ELIZABETH STREET NOOSAVILLE

 

T

The height and visual bulk of the proposed duplex dwelling is consistent with properties
within the surrounding area and doesn’t dominate the street or the surrounding areas.

The building exhibits strong vertical and horizontal elements thus providing interesting
streetscape.

Setbacks
Buildings and other structures are appropriately designed and sited to —
a) provide amenity for users of the premises as well as preserve the visual
and acoustic amenity of adjoining and nearby land sues;
b) provide adequate distance from adjoining land uses;
c) allow space for required vehicle parking;
d) allow for landscaping to be provided between buildings;
@) avoid large areas of continuous wall planes by varying the building setbacks
and using appropriate techniques to provide visual relief.

The building has been designed to comply with the required setbacks with the exception
neted later.

Qenerally the setbacks provided will ensure that the visual and acoustic amenity of
adjoining properties will not be adversely affected.

Distance from the adjoining land sues, with the exception noted later, within the
requirements of the Building Regulations and the “Minimum Boundary Setbacks...”

policy.
Provision has been allowed for adequate parking and screen planting to the boundaries.
Varied setbacks provide visual relief and articulation.

The exception to the setback requirements being achieved is the “rear” boundary
setback.

Council setbacks policy requirements of a 6.0 metre setback for this boundary to all
three levels and we are proposing a setback of 5.0 metres to the face of the building

at level 1. Setbacks on levels 2 + 3 are 5.0 metres (+) to the balcony and over 6.0
metres to the face of the building. Generally the balcony balustrade will be glass and as
sich unobtrusive

In support of this relaxation we submit the following:.

« -. The irregular shape of the block, non rectangular, imposes significant
design restrictions and controls;

° Attention has bee paid to providing significant landscaping to the street
frontage;

¢ The adjoining property at 217 Gympie Terrace is zoned Visitor Mixed

Zone and will require the same setbacks. Given that this required
setback is greatly in excess of that required by the building Regulations
we consider that the relaxation will not have an adverse effect on the
residents of the development nor any future occupants of 217 Gympie
Terrace.

SITE COVER, GROSS FLOOR AREA AND PLOT RATIO
The site cover, gross floor area and plot ration of buildings and other roofed structures —
a) results in a building scale that is compatible with surrounding development;
b) does not present an appearance of bulk tot adjacent properties, roads or other
areas in the vicinity of the site;

Used in these records

About this file

File size
5.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2385 - MCU - Multiple Housing Type 2 - Duplex [As Published].pdf · 5.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.