Skip to the record
Beware of cheap imitations.

Original source · versioned page text

7. Volume 4 - Traffic Impac Assessment

Attached to the e-mail MCU16/0084 & OPW16/0157 Development Application - Traffic Impact Assessment & Stormwater Management Plan (email 3 of 3).

of 26

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                                                                        DATE
                                                         CONTACT
                                                                        13 July, 2016
                                                         TOBY GILMOUR




Noosa Energy Centre - 140 -142 Eumundi-Noosa Rd, Noosa
Traffic Impact Assessment
For Denmac Nominees Pty Ltd
Log in to download the original file

7. Volume 4 - Traffic Impac Assessment.pdf · 2.2 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 25 pages

Page 2

TABLE OF CONTENTS
1.0     INTRODUCTION                                                            1
2.0     CONTEXT OF DEVELOPMENT SITE                                             2
2.1     DEVELOPMENT SITE                                                        2
2.2     ADJACENT ROAD NETWORK                                                   2
2.3     ACTIVE TRANSPORT FACILITIES                                             3
2.4     PUBLIC TRANSPORT SERVICES                                               4
3.0     DETAILS OF PROPOSED DEVELOPMENT                                         5
3.1     PROPOSED DEVELOPMENT                                                    5
3.2     CAR PARK REQUIREMENTS                                                   5
3.3     INTERNAL DESIGN                                                         6
3.4     ACCESS ARRANGEMENTS                                                     6
3.5     SERVICING ARRANGEMENTS                                                  7
4.0     IMPACT ASSESSMENT                                                       8
5.0     SUMMARY                                                                 9


APPENDIX A
SITE LAYOUT PLANS
APPENDIX B
ONSITE QUEUING
APPENDIX C
SERVICE VEHICLE SWEPT PATHS
APPENDIX D
DRIVEWAYS AND CARPARKING CODE




 Ref: B16239TR001_revB                -i-   Noosa Energy Centre - 140 -142 Eumundi-
                                                                   Noosa Rd, Noosa

Page 3

   Revision               Date       Description     Author                   Verifier             Approver
       A                27/06/2016      Draft        J Cavalli               T Gilmour             T Gilmour
       B                13/07/2016      Final        J Cavalli               T Gilmour             T Gilmour




Ref: B16239TR001_revB                       - ii -               Noosa Energy Centre - 140 -142 Eumundi-
                                                                                        Noosa Rd, Noosa

Page 4

1.0     INTRODUCTION

This traffic impact assessment report has been prepared on behalf of Denmac Nominees Pty Ltd
for the proposed development of an energy centre located at 140 -142 Eumundi-Noosa Road in
Noosa. The site is formally described as lot 2 on RP173876 and hereon will be referred to as ‘the
site’.
The development site consists of a service station with seven bowsers, one charging station and
a food outlet. It is proposed to provide customer entry and exit access via Eumundi-Noosa Road
and retain the existing crossover at the rear of the site onto Project Avenue for staff parking only.
The proposed site layout, prepared by Thomson Adsett, has been included in Appendix A.
This traffic impact assessment report has been undertaken to assess the car park provisions,
access requirements and the impact on the external road network of the proposed development.
The report has been compiled in a clear and concise manner and is set out as follows:
Section 2 provides an assessment of the development context including the existing land use
and traffic arrangements.
Section 3 provides details of the proposed development including car parking requirements,
access and internal manoeuvring arrangements.
Section 4 contains a high level assessment of the potential traffic impacts of the development on
the external road.
Section 5 summarises the key outcomes of the traffic impact assessment.
The Noosa Shire Council Engineering Works Code – Driveways and Carparking Code is included
in Appendix D.
This report has been prepared on behalf of and exclusive use of the Client, and is subject to and
issued in connection with the provisions of the agreement between Lambert & Rehbein and the
Client. Lambert & Rehbein accepts no liability or responsibility whatsoever for or in respect of any
use of or reliance upon this report by any third party.




 Ref: B16239TR001_revB                         -1-                  Noosa Energy Centre - 140 -142 Eumundi-
                                                                                           Noosa Rd, Noosa

Page 5

2.0     CONTEXT OF DEVELOPMENT SITE

This section of the report describes the context of the proposed development and includes a
description of the existing road network, adjacent land uses, and existing public transport facilities
servicing the site.

2.1     DEVELOPMENT SITE
The proposed development site is located at 140 -142 Eumundi-Noosa Road, Noosa, and is also
described as lot 2 on RP173876. Figure 2-1 below shows the proposed development site in the
context of the surrounding road network and the linkages to the external network. The site is
occupied by a number of commercial businesses, which currently includes an Autopro Parts
Professional and a snack bar. The site currently has two driveways fronting Eumundi-Noosa
Road with one driveway providing access to the back of house via Project Avenue. It was
observed that the surrounding land uses are primarily commercial.




                                         Development Site




                             Figure 2-1 Proposed Development Site
                                      Source: www.maps.google.com.au

2.2     ADJACENT ROAD NETWORK
Inspection of the land use, road condition, intersection characteristics, public transport facilities,
pedestrian access, and cyclist provisions surrounding the proposed development site was
undertaken. This was completed to collect information about the road network operation, safety
characteristics, public transport network and specific network / land-use factors potentially of
influence to the proposed development.


 Ref: B16239TR001_revB                          -2-                    Noosa Energy Centre - 140 -142 Eumundi-
                                                                                              Noosa Rd, Noosa

Page 6

The proposed customer access for the site is to be located on Eumundi-Noosa Road which is an
arterial road under the jurisdiction of Noosa Shire Council. The road is the primary connection
through to Noosaville to the east. Eumundi-Noosa Road was observed to have the following
characteristics at the site frontage;
         Four way, two lane road;
         Median divided;
         Posted speed limit of 60km/h;
         Kerb-to-kerb width of approximately 18m;
         Footpaths provided on both sides;
         Dedicated bicycle lane on the eastern side and a bicycle awareness zone on the western
          side; and
         Kerb and channel on both sides.
The property fronts Project Avenue to the west and currently provides access to the back of
house area and staff parking. Project Avenue was observed to have the following characteristics;
         Two way, two lane road;
         Unmarked;
         No posted speed limit, assumed 50Km/h;
         Kerb-to-kerb width of approximately 12.5m; and
         Kerb and channel.
Eumundi-Noosa Road intersects with Eeenie Creek Road at a two lane, four legs roundabout
100m to the south and with Venture Drive at a two lane, four legs roundabout 100m to the north.
These roundabouts currently facilitate U-turns for vehicles approaching the site from the north
and vehicles exiting the site to south. Both roundabouts are similar in design and were observed
to have the following characteristics;
         Two lane approach and exit from Eumundi-Noosa Road;
         Median divided approach and exit;
         Two circulation lanes; and
         Centreline line markings;
2.3       ACTIVE TRANSPORT FACILITIES
A concrete footpath is provided at the site frontage of Eumundi-Noosa Road and provides
connectivity in all directions as displayed in the Pedestrian and Cycle Network Map shown in
Appendix C. On-road cyclist facilities are also available along Eumundi-Noosa Road with a
dedicated bicycle lane provided along the eastern side and a bicycle awareness zone on the
western side.


 Ref: B16239TR001_revB                        -3-                 Noosa Energy Centre - 140 -142 Eumundi-
                                                                                         Noosa Rd, Noosa

Page 7

2.4     PUBLIC TRANSPORT SERVICES
Existing bus services currently operate along the site frontage with two stops within approximately
350m from the site as shown in Figure 2-2. These bus stops are serviced by 629 and 630 bus
routes which operate between Noosa Heads, Nambour and other intermediate locations.




                                    Figure 2-2 Bus Network




 Ref: B16239TR001_revB                        -4-                  Noosa Energy Centre - 140 -142 Eumundi-
                                                                                          Noosa Rd, Noosa

Page 8

3.0     DETAILS OF PROPOSED DEVELOPMENT

This section of the report describes the nature of the proposed development, provides a review of
the proposed access, car park provision and includes an assessment of the internal circulation
and servicing arrangement.

3.1     PROPOSED DEVELOPMENT
The proposed development consists of a service station (200m2 GFA) with seven bowsers, one
charging station and a food outlet (90m2 GFA) to be located at 140 -142 Eumundi-Noosa Road in
Noosaville. The site encompasses an area of 2,428m2 and is currently occupied by commercial
businesses. The proposed site layout is displayed in the drawings prepared by Thomson Adsett
included in Appendix A.
The proposed site plan includes two customer driveways fronting Eumundi-Noosa Road, one
being entry only and the other exit only. It is also proposed that an additional driveway be
provided for staff access at the rear of the lot fronting Project Avenue.

3.2     CAR PARK REQUIREMENTS
Table 14-51 —Minimum vehicle parking requirements of the Noosa Plan Driveways and Car
parking Code outlines the parking requirement for site usage such as the development. These
rates and requirements are outlined in Table 3-1.
                                Table 3-1 Parking Requirements

           Use              Parking Rate Required               Number             Minimum Parking Required

                                          Development Parking

  Service Station / Shop    1 space per 20m2 GFA                200m2                          10

       Food Outlet          1 space per 10m2 GFA                 90m2                           9

                                             Total Minimum Parking Requirement                 19



The total parking requirement is calculated to be 19 car parking spaces. The development
proposes to provide a total of 19 car parks, which includes four staff car parks accessed via
Project Avenue, which complies with requirements as stated in the Noosa Plan Driveways and
Car parking Code and therefore it is considered that the parking provided will adequately cater for
the site.
In accordance with the Building Code of Australia (BCA), PWD car parks must be allocated at a
rate of 1 space per 50 car parks. The development site provides one dedicated PWD spaces,
which satisfies BCA requirements.



 Ref: B16239TR001_revB                             -5-                   Noosa Energy Centre - 140 -142 Eumundi-
                                                                                                Noosa Rd, Noosa

Page 9

3.3     INTERNAL DESIGN
The proposed design features for the car park layout (as shown by the Thomson Adsett drawings,
in Appendix A) are in accordance with the requirements of AS2890.1, including the following key
items:
       For a development site with less than 100 car parks a minimum provision of two queuing
        vehicles is required; and
       Car park (Class 3) bay sizes are 5.4 metres x 2.6 metres and disable allocated bay sizes
        are 5.4 metres x 2.6 metres with an associated “shared zone” 2.4m in width.
The internal arrangement of the site with regards to the parking layout has also been designed to
accommodate the manoeuvring of a 19m B-Double (fuel tanker) as well as a 12.5m heavy rigid
vehicle, which is further discussed in Section 3.5.
The fuel bowsers are considered to be sufficiently separated from the site access to ensure all
queuing occurs onsite. The site layout will allow for each bowser to be accessible, whilst
accommodating one vehicle to queue behind the vehicle at each bowser without impacting on
accessibility to the car park, as demonstrated in Appendix B. The circulation provisions within
the site are considered to allow vehicles to enter with minimal conflicts, reducing the opportunity
for queuing back onto Eumundi-Noosa Road.
3.4     ACCESS ARRANGEMENTS
The proposed site plan includes a two driveways onto Eumundi-Noosa Road, one being entry
only and the other exit only. It is also proposed that an additional driveway be provided for staff
access only at the rear of the lot fronting Project Avenue.
All public traffic will enter the site via the left in-entry only driveway when travelling north on
Eumundi-Noosa Road and exit via the left out-exit only driveway to the north on Eumundi-Noosa
Road. The adjacent roundabouts, located approximately 100m to the north and south of the site,
will provide U-turn facilities for traffic entering the site from the north or exiting the site to the
south.
The proposed left turn entry and exit only driveways have been designed to accommodate the
swept paths of the 19m B-double fuel tanker, used to service the site, which are demonstrated in
Appendix C.
The proposed staff entrance driveway is to be provided generally in the same location and in
accordance with the current provisions. The access would facilitate parking for four staff car parks
only, which is consistent with adjacent developments with Eumundi-Noosa Road frontage.




 Ref: B16239TR001_revB                         -6-                   Noosa Energy Centre - 140 -142 Eumundi-
                                                                                            Noosa Rd, Noosa

Page 10

3.5     SERVICING ARRANGEMENTS
The proposed site is to primarily be serviced by a 19m B-Double for fuel deliveries and serviced
by a heavy rigid vehicle (HRV) for the service station and food outlet stock deliveries and refuse
collection. A loading bay has been provided for the service station and for the food outlet to
accommodate delivery vehicles and refuse collection vehicles.
A swept path assessment has been undertaken to demonstrate the manoeuvrability of a 19m
B-Double entering the site from Eumundi-Noosa Road, stopping to access the refuelling points,
and then exit the site in a forward gear via Eumundi-Noosa Road. The swept path assessment
has been included in Appendix C. The B-Double is anticipated to service the site infrequently
and will operate outside the peak times; therefore is expected to have a minimal impact on the
operation of the service station.
A swept path assessment demonstrating the movement of a heavy rigid vehicle servicing the
service station and food outlet has been provided in Appendix C.
As such, it is considered that the proposed service station has been designed to accommodate all
aspects of the day-to-day operation of the development, including minimising the impact that
service vehicles would have on the accessibility for other vehicles.




 Ref: B16239TR001_revB                       -7-                  Noosa Energy Centre - 140 -142 Eumundi-
                                                                                         Noosa Rd, Noosa

Page 11

4.0       IMPACT ASSESSMENT

Appendix 3A of the TMR Road Planning and Design Manual (RPDM) suggests that service
stations with a convenience store can generate 66 trips per hour per 100m2 GFA and that a small
food outlet can generate up to 12 trips per hour per 100m2 GFA. Utilising these rates, the traffic
generation associated with the subject land is estimated conservatively, as shown below.
                                     Table 4-1 Traffic Generation

                                                                                        Total Traffic Generated
                             Traffic Generation Rate                GFA
                                                                                             (Rounded Up)

                                               Traffic Generation

   Service station with a   66 trips per hour per 100m2
                                                                     200                          132
    convenience store                   GFA

      Small food outlet     12 trips per hour per 100m2              90                           11

                                                                    TOTAL                         143




As summarised in Table 4-1, an hourly peak generation of 143 vehicles has been assumed to
access the proposed development. It is generally accepted that there is a significant level of
“drop-in” or multi-purpose trips associated with service station developments. Given the location
of the site on a major arterial road it is considered reasonable to assume a “drop-in” rate of up
90% in the peak hours.
Therefore, it is estimated that the site will generate a total of 25 new vehicles per hour, including
14 trips per hour for the service station and 11 trips per hour for the food outlet shall be adopted.
Furthermore, as discussed in Section 2.1, the site is occupied by a number of commercial
businesses, which currently includes an Autopro Parts Professional and a snack bar. The total
commercial area is approximately 600m2 which currently generates traffic to and from Eumundi-
Noosa Road.
The amount of new traffic generated by the development is considered to be negligible based on
a high proportion of drop in trips associated with the service station use and existing traffic
generated by the site and it is assumed that the development will have an insignificant impact on
the operation of the external road network. Furthermore the location of a roundabout to the north
and the south of the proposed site are expected to facilitate any U-turn traffic with southbound
traffic travelling to and from the site. No further analysis on the external network is required.




 Ref: B16239TR001_revB                               -8-                    Noosa Energy Centre - 140 -142 Eumundi-
                                                                                                   Noosa Rd, Noosa

Page 12

5.0     SUMMARY

This traffic impact assessment report has been prepared on behalf of Denmac Nominees Pty Ltd
for the proposed development of an energy centre located at 140 -142 Eumundi-Noosa Road in
Noosa. The site is formally described as lot 2 on RP173876.
The development site consists of a service station with seven bowsers, one charging station and
a food outlet. It is proposed to provide customer entry and exit access via Eumundi-Noosa Road
and retain the existing crossover at the rear of the site onto Project Avenue for staff parking only.
The proposed site layout, prepared by Thomson Adsett, has been included in Appendix A.
The total parking requirement is calculated to be 19 car parking spaces. The development
proposes to provide a total of 19 car parks, which includes four staff car parks accessed via
Project Avenue, which complies with requirements as stated in the Noosa Plan Driveways and
Car parking Code and therefore it is considered that the parking provided will adequately cater for
the site.
The proposed site plan includes a two driveways onto Eumundi-Noosa Road, one being entry
only and the other exit only. It is also proposed that an additional driveway be provided for staff
access only at the rear of the lot fronting Project Avenue. It is considered that the proposed
development access provisions can adequately accommodate the site turnover and that the site
contains sufficient car parking that is designed in accordance with the Noosa Plan Driveways and
Car parking Code.
The proposed site is to primarily be serviced by a 19m B-Double for fuel deliveries and serviced
by a heavy rigid vehicle (HRV) for the service station and food outlet stock deliveries and refuse
collection. The proposed left turn entry and exit only driveways have been designed to
accommodate the swept paths of the 19m B-double fuel tanker, used to service the site, which
are demonstrated in Appendix C.
The potential impact of the proposed development on the external road network has been
assessed in this report. The result of the assessment demonstrates that the relatively low volume
of development generated traffic should have negligible impact on the operation of the
surrounding road network.
No traffic and transport engineering matters have been identified that should preclude approval of
the proposed residential development at this location.




 Ref: B16239TR001_revB                         -9-                  Noosa Energy Centre - 140 -142 Eumundi-
                                                                                           Noosa Rd, Noosa

Page 13

     APPENDIX A
SITE LAYOUT PLANS


[OCR of page images]
ENGINEERS + MANAGERS + SCIENTISTS

i LAMBERT & REHBEIN

APPENDIX A
SITE LAYOUT PLANS

 

Page 14

                                                                                                                                                                                                DEVELOPMENT SCHEDULE
                                                                                                                                                                                                                                                    GFA      CAR RATIO   CARS REQ'D
                                                                                                                                                                                                SERVICE STATION & SHOP                              200m²    1 / 20      10
                                                                                                                                                                                                FOOD OUTLET                                         90m²     1 / 10      9             Telephone +61 7 3840 9999
                                                                                                                                                                                                TOTAL GFA                                           290m²    TOTAL       19            [email protected]
                                                                                                                                                                                                TOTAL SITE AREA                                    2423m²                              128 Robertson Street
                                                                                                                                                                                                                                                                                       Fortitude Valley
                                                                                                                                                                                                                                                                                       Qld 4006 Australia
                                                                                                                                                                                                CARS                                                    18                             thomsonadsett.com

                                                                                                                                                                                                DISABLED SPACES                                          1                            © Copyright
                                                                                                                                                                                                                                                                                       These drawings and designs and the copyright
                                                                                                                                                                                                TOTAL CARS                                              19                             therof are the property of Thomson Adsett Pty
                                                                                                                                                                                                                                                                                       Ltd and must not be used, retained or copied
                                                                                                                                                                                                                                                                                       without written permission of Thomson Adsett
                                                                                                                                                                                                                                                                                       Pty Ltd. ABN 76 105 314 654 Trading as
                                                                                                                                                                                                                                                                                       ThomsonAdsett. Dimensions take precedence
                                                                                                                                                                                                                                                                                       over scaling. Do not measure off drawings as
                                                                                                                                                                                                                                                                                       print sizes may vary
                                                                                                                                                                                                                          LANDSCAPING
                                                                                                                                                                                                                                                                    TREE REMOVED
                                                                                                                                                                                                 LANDSCAPING TO                                    202m²
                                                                                                                                                                                                 DEVELOPMENT SITE
                                                                                                                                                                                                                                                                                      NOOSA ENERGY
                                                                                                                                                                                                 % OF DEVELOPMENT                                  8%
                                                                                                                                                                                                                                                                                      CENTRE
                                                                                                                                                                                                 SITE COVERAGE                                                      TREE RETAINED
                                                                                                                                                                                                                                                                                      140-142 EUMUNDI - NOOSA RAOD,
                                                                                                                                                                                                                                                                                      NOOSAVILLE, QLD 4566




                                                                                                                                                                                                                                                                                      for

                                                                                                                                                                                                                                                                                      DENMAC NOMINEES PTY LTD


                                                   6000                    10280          2690             5400        9000                               8000                       12510               5400               1030

                                         730              840               BATTEN SCREEN




                                                                                                                                                                                                         660
                           RL4.67                         RL6.16            STAIRS TO LOWER LEVEL                    SITE BOUNDARY                                                                                 RL9.96




                                                                                            1260
                                                          2
                                                                                                                               DA04                                                                                 2
                                                                                                      11                                                                                                                    1040




                                                                                                                                                         7870
                                                                                                                                  1                                      EXISTING BUILDING TO
                                                                                                                                                                         BE REMOVED




                                                                                                                                                                 12000
                                                                            FOOD OUTLET
                                                                               90m2
                 6350




                        BIKE RACKS UNDER




                                                                                                                                                                                                        740
                        4No. STAFF
                                                               SERVICES




                        CAR PARKS                                                                                         12470




                                                                                                                                                                                                                            8800
                                                                              RL10.50                                                                                                                                                       EXIT
                                 ROOF OVER




                                                                                            RL10.40



                                                                                                      RL10.35                                                                                        AIR &
                                                                                                                                                                                                    WATER
                                               DA03 4                                                                                                                                   ELECTRIC
                                                                                                                  ACCESSIBLE
                                                                                                                                                                                        CHARGE
                                                                                                                  CAR PARK                                                              BIKE FIX
                          RL6.00
                                                                                                                                                                                        STATION




                                                                                                                                                                                                                            8660
                                                                                                                                                                                                               2



                                                                                                                                      FUEL CANOPY OVER
        RL8.56                                                                                                           2 DA03                                                        1 DA03
                                                                                                                                                                                                                   3000
EXISTING                                                                    SERVICE
                                                                          STATION AND
TRANSFORMER                 720                                           SHOP 200m2
                                                                                                                                                                                                                                                                                          7   12/07/2016   UPDATE                               MH
                                                          2                                                       PHOTOVOLTAIC                                                                                                                                                            6   08/07/2016   UPDATE                               MH




                                                                                                                                                                                                                            10500 RL10.70
                                                                                                                                                                                                                    6                                                                     5   28/06/2016   UPDATE                               MH
                                                                                                                  PANELS                                                                             PYLON                                                                                4   16/06/2016   UPDATE                               MH
                                                                           RL10.50                                                                                                                    SIGN         DA03




                                                                                                                                                                                                                                                                                                                                                       P:\RET\16.0122.17 - NOOSA ENERGY CENTRE\2_Design\9_Revit\16.0122.17 Noosa Energy Centre.rvt
              RAIN WATER TANKS                                                                                                                                                                                                                                                            3   15/06/2016   PRELIMINARY ISSUE                    MH
                                                                                                                                                                                                                                                                                          2   14/06/2016   UPDATE                               MH
                                                                                                                                                                                                                                                                                          1   13/06/2016   PRELIMINARY ISSUE                    MH
                                                                                                                                                                                                                                            ENTRY                                      rev date            details                             init.
                                                                                                                                                                                                      RL10.50
                               SITE BOUNDARY




                                                                                                                                                                                                                                                                                      drawn                           date
                                                                                                                                                                                                                                                                                      MH                              JUNE 2016
                                                                                                                                                                                                                                                                                      checked                         date
                                                                                                                                                                                                                                                                                      TH                              JUNE 2016




                                                                                                                                                                                                                            5600
                                                                              REFUSE                                       2                                                                                                                                                          verified                        date
                                                                                                                                                                                                                                                                                      SB                              JUNE 2016
                                                                                                                          DA04


                                               RL6.73         RL7.37                                                                                                                                                                                                                  scale
                                                                                                                     SITE BOUNDARY                                                                   10560 RL11.10
                                                                                                                                                                                                                                                                                      0          1.0   2      3                5m




                                                                                                                                                                                                                                                                                      SITE LOCATION PLAN


                                                                                                                                                                                                                                                                                      scale                                  project no.




                                                                                                                                                                                                                                                                                                                                                       12/07/2016 2:28:05 PM
                                                                                                                                                                                                                                                                                      As indicated                           16.0122.17
                                                                                                                                                                                                                                                                                      sheet no.                              revision

                                                                                                                                                                                                                                                                                      DA02                                   7
                                                                                                                                                                                                                                                                                                           original sheet size - A1 (594mm x 841mm)

Page 15

   APPENDIX B
ONSITE QUEUING


[OCR of page images]
ENGINEERS + MANAGERS + SCIENTISTS

i LAMBERT & REHBEIN

APPENDIX B
ONSITE QUEUING

 

Page 16

LAMBERT & REHBEIN
 ENGINEERS   MANAGERS   SCIENTISTS


[OCR of page images]
 

 

 

 

   

 

}
”
Oo a
7
»/ ~~
JS,
é 7
:
: ee
:
=
rae Ter 5 LAMBERT & REHBEIN Fae We
012.3 4 5m DENMAC NOMINEES PTY LTD (RR ENGINEERS -MANAGERS + SCIENTISTS B16239-SK-007
140-142 EUMUNDI - NOOSA RAOD, == —~—=séd' « on >
SCALE 1:125 (A1 ‘ ON-SITE QUEUING & MANOEUVRABILITY roi oh ce Ss 5 B70 Tecate, AS SHOWN [AT
(™) NOOSAVILLE, QLD 4566 B85 VEHICLE tt a Tre at see ariow Ya

 

 

 

 

 

 

 

 

 

 

 

 

F:\Jobs\816200\B16239\ Drawings\ Traffic\816239-SK-007.dug

Page 17

          APPENDIX C
SERVICE VEHICLE SWEPT PATHS


[OCR of page images]
ENGINEERS + MANAGERS + SCIENTISTS

i LAMBERT & REHBEIN

APPENDIX C
SERVICE VEHICLE SWEPT PATHS

 

Page 18

LAMBERT & REHBEIN
 ENGINEERS   MANAGERS   SCIENTISTS


[OCR of page images]
 

 

 

 

4
£0.40

OY Oe
ia
1.37 4.10 0.1

19m B—Double KWeters

Tractor Width : Lock to Lock Time
Trailer Width 22! Steering Angle
Tractor Track 22! Articulating Angle
Trailer Track

“=

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DENMAC NOMINEES PTY LTD
Cpe im 10-142 EUMUNDI — NOOSA RAD Ti «srs [B16239-SK-005
SCALE 1:125 (A1) ‘ VEHICLE SWEPT PATH ASSESSMENT B76 Vccate, aS SHOWN [AT
NOOSAVILLE, QLD 4566 19m B-DOUBLE VEHICLE Fe oa [Fle ete BELOW |e

 

 

 

 

F:\Jobs\816200\B16239\ Drawings \Traffic\816239-SK-005.dug

Page 19

LAMBERT & REHBEIN
 ENGINEERS   MANAGERS   SCIENTISTS


[OCR of page images]
 

12.5m_HRV_INGRES

Ae

 

Do

 

 

 

 

 

 

OQfo

 

2.40 6.60

HRV meters

Width : 2.50
Track : 2.50
Lock to Lock Time : 6.0
Steering Angle : 35.2

F

P

 

 

 

 

 

 

 

 

2.40 6.60

HRV

Width
Track

OKO

Sy
meters OF

: 2.50
: 2.50

Lock to Lock Time : 6.0

Steering Angle

1 35.2

v

 

 

0 12 3 4 Sm
(cilia!

SCALE 1:125 (A1)

 

on B B/I/16
A syrsi6. | Seale_AS_ SHOWN Al
HEAVY RIGID VEHICLE Approved __TG Rev. Date | file Refi SEE BELOW [sr
F)\Jobs\(816200\\B16239 Drawings  Traffic\B16239-SK—006.dwg

 

140-142 EUMUNDI - NOOSA RAOD,
NOOSAVILLE, QLD 4566

Client:
DENMAC NOMINEES PTY LTD

 

 

Title:

VEHICLE SWEPT PATH ASSESSMENT

 

 

(h LAMBERT & REHBEIN

ENGINEERS, SCIENTISTS

 

 

Figure No

B16239-SK-006

 

 

 

 

 

 

 

 

Page 20

           APPENDIX D
DRIVEWAYS AND CARPARKING CODE


[OCR of page images]
ENGINEERS + MANAGERS + SCIENTISTS

i LAMBERT & REHBEIN

APPENDIX D
DRIVEWAYS AND CARPARKING CODE

 

Page 21

A.1                  ENGINEERING WORKS CODE – DRIVEWAYS AND
                     CARPARKING CODE
SPECIFIC OUTCOMES                    PROBABLE SOLUTIONS                    RESPONSE

14. 113 General

 O1 Vehicular access does not        S1.1 Vehicular access is located      O1 Complies
 adversely impact on safety,         and designed in accordance with
 capacity and operations of the      AUSTROADS-Guide to Traffic            Refer to Traffic Report, prepared by

 existing or planned road network,   Engineering Practice requirements     Lambert & Rehbein,

 the proposed driveway,              for sight distance and Section 3 of   B16239TR001_revA.
 cycleways or pedestrian pathway     AS2890.1 Parking Facilities;
 systems.
                                     AND

                                     S1.2 Only one footpath crossing is
                                     provided;

                                     AND

                                     S1.3 Driveways, other than within
                                     any setback have a maximum grade
                                     in accordance with Section 3 of
                                     AS/NZS 2890.1

O2 Driveways and crossovers—         S2.1 Design of the driveway across    O2 Complies
                                     the footpath is in accordance with
a) are suitable and safe for their   Council’s Standard Drawings 9002      The proposed access has been
intended use; and                    or 9005 as appropriate for the        designed to accommodate the

                                     particular type of development as     swept path of a 19m B-Double and
b) match Council infrastructure.                                           HRV design vehicles and more than
                                     annotated on the drawings;
                                                                           adequately accommodate the
                                     AND                                   quantum and turnover of vehicle
                                                                           movements.
                                     S2.2 Driveways are designed and
                                     constructed in accordance with
                                     Council Standard Drawings 9014,
                                     9019, 9020, 9021, as appropriate
                                     for the particular type of
                                     development as annotated on the
                                     drawings;

                                     AND

                                     S2.3 The change in grades in the
                                     driveways and ramps is in
                                     accordance with Section 3 of
                                     AS2890.1 Parking Facilities

                                     .

Page 22

SPECIFIC OUTCOMES                       PROBABLE SOLUTIONS                      RESPONSE

O3 In commercial zoned areas, the       S3.1 Design of multi-tenanted           O3 Complies
number of driveways across              developments in commercial zoned
pedestrian footpaths is minimised.      areas include shared driveways and The proposed development
                                        parking areas;                     incorporates separated access
                                                                                egress driveway crossovers. The
                                        AND                                     proposed access arrangement is a
                                                                                reduction of the current layout of
                                        S3.2 Driveways are located so they      two two-way driveways.
                                        abut existing driveways of adjoining
                                        development where practicable and
                                        reciprocal easements are created to
                                        reduce the sealed driveway width.

O4 Vehicular access does not            S4.1 Footpath and kerb crossings        O4 & O5 Complies
adversely impact on the capacity,       are located clear of existing
operations and maintenance of the       stormwater inlet structures, water      The proposed access has been

existing infrastructure;                and sewerage infrastructure fittings, designed to minimise the impact on
                                        any other exiting utility             existing infrastructure and the local
AND                                     infrastructure, existing landscaping    street scape.

                                        and vegetation.
O5 Vehicular access does not
adversely impact on the integrity of    S5.1 No solution provided
existing landscaping or native
vegetation

O6                                      S6.1 For—                               Refer to Civil Engineering Report.

Driveway run-off is filtered prior to   a) Ancillary dwelling unit, Multiple
leaving the premises                    housing Types 1 or 2 if less than 5
                                        carparking spaces, Visitor
                                        accommodation Type1 and Home-
                                        based business Type 3—the
                                        driveway is formed to drain to
                                        landscaped areas; and

                                        b) for other uses—grease and oil
                                        arrestors or stormwater quality
                                        improvement devices are
                                        incorporated into the design to treat
                                        run-off prior to run-off exiting from
                                        the premises.

Table 14-50 — Carparking and manoeuvring

14.114 Carpark design and layout

O7 Sufficient carparking is provided S7.1 The number of parking and             O7 Complies
to accommodate the number and           loading bays is not less than the
type of vehicles likely to be           minimum number specified in Table       The proposed development

generated by the development            14-51 Vehicle Parking                   provides 19 car parks and therefore
                                                                                the parking arrangement generally

Page 23

SPECIFIC OUTCOMES                        PROBABLE SOLUTIONS                      RESPONSE

having regard to the specifics of the Requirements;                              complies with the requirements of
use including—                                                                   Noosa Plan Driveways and Car
                                                                                 Parking Code.
a) the type and intensity of land use;

b) any existing parking available on
the site;

c) hours of operation;

d) likely numbers of users;

e) the peak parking demand periods
of uses on the site; and

f)the availability of alternative
carparking

O8 The layout of the development         S8.1 Parking bays, manoeuvring          O8 Complies
provides adequate, clearly defined       areas, queuing areas, loading,
and easily accessible—                   setdown and pickup areas and            Generally complies with the Noosa

                                         driveways are designed to the           Plan Driveways and Car Parking
a) on-site vehicle parking and           standards set out in Sections 2 and     Code and AS 2890.1. Performance
manoeuvring areas; and                   3 of Australian Standard AS             outcomes are discussed in the

                                         2890.1Parking Facilities (Part 1: Off- Traffic Report, prepared by Lambert
b) loading and manoeuvring areas
                                         street Carparking)and AS 2890.2 – & Rehbein, B16239TR001_revA.
for delivery and service vehicles
                                         Off-street Parking (Part 2:
                                         Commercial Vehicles);

                                         AND

                                         S8.2 The number of loading bays is
                                         not less than the minimum number
                                         specified in Table 14-51.

O9 Parking areas are located where S9.1 Carparking areas are                     O9 Complies
they will not unduly conflict with       accessed from rear laneways where
pedestrians and will not dominate        practicable                             The proposed access has been

the streetscape.                                                                 designed to minimise the impact on
                                                                                 pedestrians and the local street
                                                                                 scape.

O10 Provision is made for a              S10.1 Carparking spaces are             O10 Complies
reasonable number of on site             provided for people with disabilities
carparking spaces identified and       at the rate specified in Section 2.4.5 The proposed development
reserved for people with disabilities. of AS 2890.1 –Parking Facilities       provides the one disabled car park,

                                       (Part 1: Off-street Carparking)        included within the 19 car parks
                                                                                 which complies with the Building
                                                                                 Code of Australia

Page 24

SPECIFIC OUTCOMES                      PROBABLE SOLUTIONS                     RESPONSE

O11 Access and egress points do        S11.1 Vehicle manoeuvring areas        O11 Complies
not impact on the safety and           are provided in accordance with
operations of the road system.         Section 3 of AS 2890.1 Parking         The proposed access has been

                                       Facilities (Part 1: Off-street         designed to accommodate the

                                       Carparking) so vehicles enter and      swept path of a 19m B-Double and

                                       leave the site in a forward gear.      HRV design vehicles in a safe
                                                                              manner as discussed in the Traffic
                                                                              Report, prepared by Lambert &
                                                                              Rehbein, B16239TR001_revA.

O12 Parking areas are designed to- S12.1 At locations where pedestrian O12, O13, O14 and O15 Complies
                                       and vehicle conflicts are likely to
a) provide a progressive reduction     occur –                                Refer to Traffic Report, prepared by
in speed between the external road                                            Lambert & Rehbein,
and internal parking spaces;           a) sight distances of at least 2.5     B16239TR001_revA.
                                       seconds of travel time at the
b) ensure lower speeds near areas      designated speed are provided;
of high pedestrian activity through
the use of appropriate road            b) splayed corners on structures are
geometry or devices designed to        incorporated;
limit speed; and
                                       c) landscaping is designed to allow
c) maintain sight distances which      clear views;
are appropriate for the likely
operating speeds in all areas of       d) sign placement ensures that

potential pedestrian/vehicle and       views are not impeded;

vehicle/vehicle conflict;
                                       S13.1 In large open car parks with

O13 A clearly defined pedestrian       greater than 200 car parking

network is provided that –             spaces, a pedestrian path between
                                       parking spaces is provided on every
a) is located in areas where people    second aisle;
will choose to walk;
                                       S14.1 No probable solution
b) ensures that pedestrian             identified;
movement through car parking
areas or structures are along aisles   S15.1 Lighting is provided in

rather than across them;               accordance with Australian
                                       Standard 1158.1:1997 - Road
O14 Provision is made for              Lighting - Vehicular Traffic
pedestrian and vehicular queues at     (Category V) Lighting -Performance
conflict points;                       Installation and Design
                                       Requirements.
O15 Parking areas are lit to provide
security for night-time users.

O16 In mixed use areas of Business S16.1 Resident carparking is limited NA
centres residents do not compete       to one space per dwelling unit or
with customers for carparking          accommodation unit.
spaces.
                                       AND S16.2 Resident carparking is

Page 25

SPECIFIC OUTCOMES                     PROBABLE SOLUTIONS                    RESPONSE

                                      not located in the road reserve or
                                      between the residential or business
                                      building and the principal street
                                      frontage.

O17 Car parking areas are             No solution provided                  Refer to Civil Engineering Report.
landscaped to—

a) provide shade;

b) maximise infiltration of
stormwater run-off;

c) define parking areas;

d) reduce direct visibility of car
parking areas from external
viewpoints;

e) soften views of hardstand areas

O18 Development with the potential No solution provided                     NA
to generate significant traffic and
parking impacts gives appropriate
consideration to transport and land
use issues

Motor Cycles & Motor Scooters

O19 Designated Motor cycle or         S19.1 For Commercial businesses,      Alternate solution
motor scooter parking spaces          Entertainment & dining business,
reduce the reliance on cars.          Industrial business Types 1 and 2,    It is proposed that motorcycles can

                                      Retail business Types 2, 4, 5, 6 and utilise the provided car parks to
                                      7, Education Types 1 and 2, Open     allow flexibility of use on site.
                                      Space, Wellbeing Uses and
                                      Transport Types 1, 2, 3 and 4 motor
                                      cycle parking spaces accord with
                                      Planning Scheme Policy
                                      PSP26Motor Cycle & Motor Scooter
                                      Parking

O20 Carparks are designed to          S20.1 Grease and oil arrestors or     Refer to Civil Engineering Report.
ensure run-off is treated to remove   stormwater quality improvement
pollutants prior to leaving the       devices are incorporated into the
premises.                             design to treat run-off prior to it
                                      leaving the premises.

O21 Carparking areas are designed No solution provided                      Refer to Civil Engineering Report.
to ensure drainage without the use
of pumps or other electrical

Page 26

SPECIFIC OUTCOMES                          PROBABLE SOLUTIONS                       RESPONSE

apparatus

O22 Site layout and building design        S22.1 Below ground components of Refer to Civil Engineering Report.
provides for soft landscaping to be        buildings, including car parks, do
established.                               not extend beyond the above
                                           ground footprint to allow for the
                                           provision of landscaping, particularly
                                           within building setbacks

Education Types 1, 2 or 3

O23 Carparking and setdown areas S23.1 Paved setdown areas are                      NA
are designed and located to                provided within the site;
facilitate their safe and efficient use.
                                           AND

                                           S23.2 For a minimum of 50% of
                                           carparking spaces, pedestrian
                                           access to buildings is not across or
                                           through driveways, carparks,
                                           setdown or manoeuvring areas;

                                           AND

                                           S23.3 Carparking and setdown
                                           areas are visible from off-site.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.