Original source · versioned page text
Appendix G - Bushfire Hazard Assessment
Attached to the e-mail MCU17/0551 - Information Response - 20 Trading Post Rd Cooroy.
19 & 20 Trading Post Road Cooroy QLD March 2018 Bushfire Hazard Assessment Report SECTION 4 NOOSA PLAN Bushfire Hazard Areas (Natural hazards and Natural Resources Overlays Response Hazardous materials S6.1 Hazardous materials are not Complies. O6 Public safety and the manufactured and stored in a Bushfire Hazardous materials are not environment are not adversely Hazard Area. proposed to be manufactured or affected by the detrimental stored at the site. impacts of bushfire on hazardous materials manufactured or stored in bulk. 13.34 Siting, design and construction 13.34.1 S7.1 Uses and works including building Complies. O7 Uses and works including works are sited— building works are sited, designed a) on lots greater than 2500m2; Dwelling units are to be sited at and constructed to— i) in locations of lowest hazard within substantial setback from classified a) minimise the number of people the lot (Figure 13.5 provides guidance); vegetation. The maximum Bushfire and property subject to bushfire and Attack Level at Sites 229 and 230 is risk; and ii) to achieve setbacks from hazardous BAL-12.5. This is considered an b) maximise the protection of vegetation of 1.5 times the predominant acceptable low level of risk for the people and property during the mature canopy tree height or 10m more vulnerable members of the passage of a fire front. whichever is the greater; and community occupying the dwelling iii) 10m from any retained vegetation units. Sites 221 to 228 inclusive are strips or small areas of vegetation; and located in Low Hazard areas, iv) so that the elements of the outside the maximum 100m buffer development least susceptible to fire are area for bushfire. sited closest to the bushfire hazard; Setback to classified vegetation b) on lots 2500m2 or less - to maximise exceeds 1.5 times predominant setbacks from hazardous vegetation37 mature canopy height. Closest setback is 82m to the perimeter of lots. The narrow strip of trees fringing the boundary may act as a windbreak, radiant heat barrier and ember filter in a bushfire event, with a protective function to the subject site. 13.35 Water supply for fire fighting O8 An adequate and accessible S8.1 For premises not in a water service Complies. water supply is provided for fire area— each lot has an accessible dam, Reticulated mains pressure water is fighting purposes can be accessed swimming pool or water tank accessible available at all proposed Sites. Fire by fire fighting appliances. by the fire brigade that contains at least hydrants to be installed in 5000 litres of water. accordance with requirements of relevant Australian Standards and 13 those of utilities provider. Adequate pressure and flow rate Page should be confirmed prior to occupancy. Brisbane Bushfire Consulting Pty. Ltd. Bushfire Consultant, Architect BOAQ ARBV P.O. Box 219, Point Lookout Qld 4183 [email protected] brisbanebushfire.com.au Mob 0490 494 111
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.