Appendix G - Bushfire Hazard Assessment

Attached to the e-mail MCU17/0551 - Information Response - 20 Trading Post Rd Cooroy.

of 37

Page text shows just the words. Original shows the document exactly as it was published.

                                                           19 & 20 Trading Post Road Cooroy QLD March 2018
                                                                        Bushfire Hazard Assessment Report

Step 4: Effective slope of land under the classified vegetation (Clause 2.2.5, per Figure 2.2)

 Effective slope         North East           South-West          South-East            North-West
 Slope under the
                         Flat land            n/a                 n/a                   n/a
 classified
 vegetation

Step 5: Determination of Bushfire Attack Level (BAL)

                         North East           South-West          South-East            North-West
 BAL value for
                         BAL- 12.5            BAL- LOW            BAL- LOW              BAL- LOW
 each face


The highest BAL category found applies. The BAL for Site 229 and 230 is BAL-12.5 all
sides of Dwelling. No reduction for shielding permitted at BAL-12.5.
Per Appendix G 4 of AS 3959-2009, the Bushfire Attack Level (BAL) is

BAL-12.5           The risk is considered to be LOW.

There is a risk of ember attack. The construction elements are expected to be exposed to a heat flux
not greater than 12.5 kW/m2.

Step 6: Determine the appropriate construction requirements, per Table 3.1

 Bushfire             Classified vegetation     Description of predicted bushfire           Construction
 Attack Level         within 100 m of the       attack and levels of exposure               to comply
 (BAL)                site and heat flux                                                    with section
                      exposure thresholds                                                   per AS 3959-
                                                                                            2009
 BAL-12.5             <12.5 kW/m2               Ember attack                                3 and 5

Construction to comply with Sections 3 and Section 5 of AS 3959-2009 for deemed-to-
satisfy construction provisions compliant with the BCA.
                                                                                                                 18
                                                                                                                 Page




Brisbane Bushfire Consulting Pty. Ltd.                               Bushfire Consultant, Architect BOAQ ARBV
P.O. Box 219, Point Lookout Qld 4183                                             [email protected]
brisbanebushfire.com.au                                                                       Mob 0490 494 111
Log in to download the original file

Appendix G - Bushfire Hazard Assessment.pdf · 4.7 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.