    NOOSA COUNCIL
    APPROVED PLAN
51983.3225.22 19 MAY 2025


[OCR of page images]
LEGEND NOTE NOTES NOTE:

COL STEEL COLUMN UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN THESE DRAWINGS ARE DESIGN CONCEPTS
BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL ONLY AND SHALL NOT BE USED IN ANY
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT WAY FOR STRUCTURAL PURPOSES. REFER
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

REQUIREMENTS.

 

 

Parwn>

 

4

 

 

 

 

 

 

 

 

 

BOUNDARY
(DEDICATED LOT
EXCLUSIVE USE AREA)

ADJOINING
VILLA
ROADWAY

BOUNDARY,

7

 

 

 

 

 

BOUNDARY

 

 

 

 

 

 

 

 

 

TO BE CHECKED AND VERIFIED ON SITE
@ ROOM DIMENSIONS DEMOLISH EXISTING WALLS TO EXTENT SHOWN.
DEMOLISH EXISTING CONCRETE GROUND SLAB.
|
VILLA e— — ——
CONFIRM SUFFICIENT RECTIFICATION WITH
VILLA EXTENT SHOWN.
ENSUITE ATH |
PLASTERBOARD PLASTERBQARDs7osagqmm 9 Po CUPBOARDS AND RETAIN FOR REINSTATEMENT
| | ASTERBOARD
EAVESILINE 0)
ASSOCIATED WORKS.
INCLUDING TOILETS, SHOWERS AND BASINS.
(CLIENT TO CONFIRM).
ENGINEER TO SUIT NEW WORKS.
16. DEMOLISH EXISTING TELEVISION.
SHOWN.
21, DEMOLISH EXISTING FLOOR TILES TO EXTENT

2. ALL SETBACK/SETOUT DIMENSIONS ARE
PRIOR TO CONSTRUCTION.
f- “
NOTE: DEMOLITION NOTES
SHOWN ARE TO DEMOLISH EXISTING DOORS AND WINDOWS.
DEMOLISH EXISTING STAIRS AND HANDRAIL.
ADJOINING FINISHED WALL FACES.
DEMOLISH EXISTING SCREEN STRUCTURES.
DEMOLISH EXISTING BRACING FRAMES. NOTE:
BOUNDARY ADJOINING STRUCTURAL ENGINEER TO SUIT NEW WORKS,
— — © - - 7. DEMOLISH EXISTING GROUND PAVERS TO
8. DEMOLISH EXISTING JOINERY BENCH.
p—€) 1965x1570mm = 1670x470mm WC 9, REMOVE EXISTING TUB, EQUIPMENT AND
(CLIENT TO CONFIRM).
10. DEMOLISH EXISTING HOT WATER SYSTEM AND
. DEMOLISH EXISTING FLOOR TO EXTENT SHOWN.
12. DEMOLISH EXISTING SANITARY FIXTURES
13. DEMOLISH EXISTING KITCHEN JOINERY. RETAIN
EXISTING EQUIPMENT FOR REINSTATEMENT
14. DEMOLISH EXISTING COLUMN. NOTE: CONFIRM
SUFFICIENT RECTIFICATION WITH STRUCTURAL
15. DEMOLISH EXISTING AIR CONDITIONER AND WALL
MOUNTING BRACKETS
17. DEMOLISH EXISTING DOWNPIPE.
18. DEMOLISH EXISTING DECKING TO EXTENT
19. DEMOLISH EXISTING DECK BALUSTRADE.
20. DEMOLISH EXISTING BEDROOM JOINERY.
“ ADJOINING sHovin.
poe 22. DEMOLISH EXISTING CARPET FLOORING TO
S, EAVES LINE OVER EXTENT SHOWN.
\s— SHARED 23. DEMOLISH EXISTING ROOF SHEETING.

 

— eee
ADJOINING BOUNDARY ROADWAY 24. DEMOLISH EXISTING EAVES GUTTERS.
25, DEMOLISH EXISTING CEILING FITTINGS AND
SHARED ~~ “BOUNDARY FIXTURES.
(DEDICATED LOT 26, DEMOLISH EXISTING CEILING LINING.
ROADWAY EXCLUSIVE USE AREA)

 

 

 

 

 

NOTE:
PLANS REPRESENT GENERAL DESIGN

 

 

NOOSA COUNCIL DEMOLITION INTENT ONLY. BUILDING SCOPE TO
APPROVED PLAN (ot \ DEMOLITION CEILING PLAN - LEVEL 2 SN ALLOW FOR FULL DEMOLITION AND REBUILD.
1983.3225.22 19 MAY 2025 | {~~ soar FULL DEMOLITION SCOPE REQUIRED TO SUIT
PROPOSED WORKS TO BE CONFIRMED ON SITE.

 

 

 

 

NOTES: AMENDMENTS PROJECT “DRAWINGCREATED - [email protected]. THS OnAninG SHOH's DESIG NTENT ONLY AL DENSON np. | EY_OATE__DESORPTON ey FOR APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 4:100

SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. A |17.08.2023] ISSUE FOR BUILDING APPROVAL cB
PROJECT NO. REVISION

3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 14.01.2025] PROJECT SCOPE ADJUSTMENTS 6a ‘ADDRESS www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION, © | 15.01.2025) UPDATED PROJECT SCOPE ADJUSTMENTS GB 22048 D RUG Es [lt NES
4. DO NOT SCALE THIS DRAWING. D | 28.01.2025) PROJECT SCOPE ADJUSTMENTS GB 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 COO [email protected]

 

COPYRIGHT: | AUTHOR: GB: DRAWING WG. No, ere RPP
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY omc an SESE

THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 420x297mm) DEMOLITION CEILING PLAN - LEVEL 2 A056 ODETTE)

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

 

 

Used in these records

About this file

File size
7.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SUPERSEDED - Compiled Approved Plans - 51983.3225.22 (As Published).pdf · 7.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.