KEY SITE REQUIREMENTS
MFR METAL FLAT ROOF NGL NATURAL GROUND LEVEL SITE 1939.64m2
MPR METAL PITCHED ROOF FGL FINISHED GROUND LEVEL ALLOWED COVERAGE: 40% / 775.85m2 ALLOWED GFA: 40% / 775.85m2 REQUIRED SOFT LANDSCAPE: 20% / 388.00m2
N
FR CONCRETE FLAT ROOF RL FINISHED LEVEL
DP DOWN PIPE ACTUAL COVERAGE: ACTUAL GFA: 39% / 760.00m2 ACTUAL SOFT LANSCAPE: 30% / 587.91m2
GROUND LEVEL 33.92% / 658m2
RH RAINHEAD UPPER LEVEL 23.25% / 451m2
FALL DIRECTION
GARAGE WALL IN ACCORDANCE
WITH QDCC MEAN HEIGHT OF
NOT MORE THEN 3.5
349oo01'30"
349 01'30" // 20.000
20.000
358o05' /
SETBACK
12.703 349o01'30" / 34.270
2000
GROUND FLAT ROOF
LAWN LAWN
SETBACK
1500
70
GROUND FR PLANTER 1.3
BBQ RL
12.5o
TPR
UPPER TERRACE
FG
FG
12.5o
TPR
LAWN
CARPARK 00 POOL
.1
CISTERN
TILED L6
12.5o
TERRACE
TPR
TPR TPR R
CISTERN
12.5o
PITCHED 12.5o FLAT ROOF
NOOSA
TILED COURTYARD
ROOF TPR TPR 0
PITCHED DINING FG
FG .15
L2
CISTERN
12.5o 12.5o
ROOF R
70
CISTERN
0 .3
.70 L1
12.5o
TPR
2 R
RL PLANTER
0 0
12.5o
TPR
2.7
TPR RL
12.5o
FRONT GATE STONE COLUMN
PLANTER
LAWN
TO RUN THROUGH
UPPER TERRACE PLANTER
FEATURE TIMBER BEAMS
259 01'30" / 21.077
FEATURE TIMBER BEAMS
0
o
LAWN 2.30 GLASS PANEL
FG
RL
12.5o
FG
TPR
FEATURE TIMBER
BEAMS
DRIVEWAY COURTYARD
0
FRONT PATH
.70
0 L2 LAWN
1.80 R GLASS PANEL
50
RL 2.6 TILED
POOL
PLANTER
RL FG
TPR
PITCHED
TPR UPPER SPA POOL
6000 12.5o 12.5o TERRACE
SETBACK ROOF TERRACE
0
.35 .1 00 JETTY
2
L6 50
0 RL 2.1
.10 LAWN FEATURE TIMBER BEAMS
DRIVEWAY PLANTER R
2
00
GLASS PANEL RL
RL 2.4
DEED
RL
12.5o
TPR
FEATURE TIMBER
FEATURE TREE BEAMS
BOUN
DARY
FG
RP90
0
.37
12.5o
TPR
1986
STONE COLUMN
TO RUN THROUGH
PLANTER
R L1
FG
TPR
UPPER TERRACE
12.5o 0
0 TILED 2 .70
0
2.6
TPR
PITCHED
TPR RL
RL 12.5o 12.5o
SERVICES
RIVER
PLANTER
ROOF
UPPER TERRACE
LAWN DRIVEWAY
FLAT ROOF
00
2.3
12.5o
TPR
RL
CISTERN FG
CISTERN
12.5o
TPR
LAWN 70
1.3
ACK
RL
1500
GROUND FR GROUND FR
SETB
CISTERN DASHED LINE OF 10m
OFFSET FROM MHWS
PLANTER POOL
UPPER PLANTER TERRACE
CONVERSATION
BOX
FLAT ROOF 50 PIT
FG FG 2.1
182 o30
' / 52 RL
.304 0
GROUND FR .40 LAWN
ACK
L 1
2000
CISTERN R
SETB
0 50
.70 .3
FG
L2 L1
PLANTER
R TERRACE R
GROUND FR
.330
R L1
180 o00'
/ 21.195
SITE PLAN
PAUL CLOUT DESIGN GENERAL NOTES:
Suite 3, 44 MARY STREET, NOOSAVILLE Use written dimensions only. DO NOT scale drawings. Contractors to verify all dimensions on site prior to REVISION DATE REV DESCRIPTION
CLIENT NAME: Pickering, Brendan & Angelique
PO BOX 152, NOOSAVILLE, QLD 4566. commencing works. Site location is Category W41 or to engineer's requirements. These drawings are to be SITE ADDRESS: 92 Hilton Terrace, Noosaville 15/05/2025 A CLIENT ISSUE
BSA LICENCE: 1066417 read in conjunction with engineer's design and details, the accompanying building specification and schedule 06/01/2026 B SPS ISSUE
PH: (07) 5440 5388
of finishes. If in doubt, please request clarification. DO NOT ASSUME.
@COPYRIGHT PAUL CLOUT DESIGN PTY LTD.
DRAWING TITLE:
STAGE:
Site Plan
Council Drawings
C 14/08/2026 C COUNCIL ISSUE
[email protected]
www.paulclout.com
NOT FOR CONSTRUCTION SCALE: 1:100 ON A1 DRAWING No. 00.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of sections 2 to 5 (of 12)
Section 2
KEY SITE REQUIREMENTS NOTES
CSD CAVITY SLIDING DOOR MFR METAL FLAT ROOF SD SMOKE DETECTOR SITE 1939.64m2 · ALL TOILET DOORS TO HAVE LIFT OF HINGES · LIVABLE HOUSING DESIGN STANDARD 2022 COMPLIANT BATHROOM TO INCLUDE MINIMUM 820mm CLEAR OPENING, HOBLESS / STEP FREE ENTRY,
· RL'S ARE ASSUMED ONLY AND SHALL BE VERIFIED BY BUILDER PRIOR TO NO LIP GREATER THEN 5MM. REFER TO figure A4(3) ON QDC MP4.5 FOR FURTHER DETAILS. ENSURE RE-INFORCING IS DONE AS PER PART 6 OF
D DOOR MPR METAL PITCHED ROOF HT HOSE TAP ALLOWED COVERAGE: 40% / 775.85m2 ALLOWED GFA: 40% / 775.85m2 COMMENCEMENT OF SITE WORKS LIVABLE HOUSING CODE.
N
GD GLASS DOOR CONCRETE FLAT ROOF G GAS POINT · ALL BASINS & BATHS TO HAVE OVERFLOWS · ALL RELEVANT PAHTS & FLUSH TRANSITIONS AS REQUIRED BY NCC LIVABLE HOUSING CODE TO BE INSTATED TO CODE BY BUILDER. VOS WITH
FR
· PDR TO MEET REQUIREMENTS STATED IN THE 'LIVABLE HOUSING DESIGN STANDARD DESIGNER & CERTIFIER IF REQUIRED.
W WINDOW DP DOWN PIPE NGL NATURAL GROUND LEVEL ACTUAL COVERAGE: ACTUAL GFA: 39% / 760.00m2 2022' · DOWN PIPES & ROOF DRAINAGE LOCATIONS ARE SUGGESTED ONLY AND BUILDER SHOULD ENSURE ADEQUATE STORMWATER FALL & DRAINAGE
GROUND LEVEL 33.92% / 658m2 · PDR TO HAVE MECHANICAL VENTILATION AS REQUIRED
FG FLOOR GULLY RH RAINHEAD FGL FINISHED GROUND LEVEL UPPER LEVEL 23.25% / 451m2 · ALL BASINS & BATHS TO HAVE OVERFLOWS · DRAINAGE SHOULD BE CONCEALED WITHIN SLAB WHERE NOTED.
PD PLUMBING DUCT FALL DIRECTION RL FINISHED LEVEL · FOR ALL LANDSCAPING REFER TO LANDSCAPING CONSULTANTS DETAILED DRAWINGS · FOR ALL WET AREAS, SET DOWN FLOOR CONSTRUCTION TO PROVIDE TILED FLOOR FLUSH WITH ADJOINING FFL, FALL TO WASTE, DROP SHOWER
349o01'30" / 20.000
358o05' /
12.703 349o01'30" / 34.270
OUTLINE OF
LEVEL ABOVE
OUTLINE OF
LEVEL ABOVE
OUTLINE OF
LEVEL ABOVE
OUTLINE OF
LEVEL ABOVE
259 01'30" / 21.077
o
DEED
BOUN
OUTLINE OF
DARY
LEVEL ABOVE
RP90
1986
OUTLINE OF
LEVEL ABOVE
0
.25
STORAGE
SOLAR
-0
A BATTERY DASHED LINE OF
LEVEL ABOVE RL A
SOLAR NEXT LEVEL
BATTERY STORAGE ELEVATORS -
UP
ELTEC HLB
1 (SLIDING DOOR MS
SOLAR
PLANTROOM 2
- XXL) TA SHAFT
BATTERY TILES
3
LIFT
2550 CEILING (180mm MINIMUM
4 PIT DEPTH)
50
STORAGE
SOLAR
.2 5 9
BATTERY -0 STAIRS
RL 6 8
7 STAIRCASE LANDING
HOT HOT HOT
WATER WATER WATER STAIRWAY CONSTRUCTION
IN ACCORDANCE WITH
NCC ABCB 11.2.2
DASHED LINE OF 10m
OFFSET FROM MHWS
2950 FLOOR TO FLOOR, 16 RISERS
@184mm W/ 15 TREADS @ 340 MID OUTLINE OF
POINT PLUS 20mm NOSING LEVEL ABOVE
182 o30
' / 52.3
04
OUTLINE OF
LEVEL ABOVE
180 o00'
/ 21.19
5
BASEMENT PLAN
PAUL CLOUT DESIGN GENERAL NOTES:
Suite 3, 44 MARY STREET, NOOSAVILLE Use written dimensions only. DO NOT scale drawings. Contractors to verify all dimensions on site prior to REVISION DATE REV DESCRIPTION
CLIENT NAME: Pickering, Brendan & Angelique
PO BOX 152, NOOSAVILLE, QLD 4566. commencing works. Site location is Category W41 or to engineer's requirements. These drawings are to be SITE ADDRESS: 92 Hilton Terrace, Noosaville 15/05/2025 A CLIENT ISSUE
BSA LICENCE: 1066417 read in conjunction with engineer's design and details, the accompanying building specification and schedule 06/01/2026 B SPS ISSUE
PH: (07) 5440 5388
of finishes. If in doubt, please request clarification. DO NOT ASSUME.
@COPYRIGHT PAUL CLOUT DESIGN PTY LTD.
DRAWING TITLE:
STAGE:
Basement Plan
Council Drawings
C 14/08/2026 C COUNCIL ISSUE
[email protected]
www.paulclout.com
NOT FOR CONSTRUCTION SCALE: 1:100 ON A1 DRAWING No. 01.0
Section 3
KEY SITE REQUIREMENTS NOTES
CSD CAVITY SLIDING DOOR MFR METAL FLAT ROOF SD SMOKE DETECTOR SITE 1939.64m2 · ALL TOILET DOORS TO HAVE LIFT OF HINGES · LIVABLE HOUSING DESIGN STANDARD 2022 COMPLIANT BATHROOM TO INCLUDE MINIMUM 820mm CLEAR OPENING, HOBLESS / STEP FREE ENTRY,
· RL'S ARE ASSUMED ONLY AND SHALL BE VERIFIED BY BUILDER PRIOR TO NO LIP GREATER THEN 5MM. REFER TO figure A4(3) ON QDC MP4.5 FOR FURTHER DETAILS. ENSURE RE-INFORCING IS DONE AS PER PART 6 OF
D DOOR MPR METAL PITCHED ROOF HT HOSE TAP ALLOWED COVERAGE: 40% / 775.85m2 ALLOWED GFA: 40% / 775.85m2 COMMENCEMENT OF SITE WORKS LIVABLE HOUSING CODE.
N
GD GLASS DOOR CONCRETE FLAT ROOF G GAS POINT · ALL BASINS & BATHS TO HAVE OVERFLOWS · ALL RELEVANT PAHTS & FLUSH TRANSITIONS AS REQUIRED BY NCC LIVABLE HOUSING CODE TO BE INSTATED TO CODE BY BUILDER. VOS WITH
FR
· PDR TO MEET REQUIREMENTS STATED IN THE 'LIVABLE HOUSING DESIGN STANDARD DESIGNER & CERTIFIER IF REQUIRED.
W WINDOW DP DOWN PIPE NGL NATURAL GROUND LEVEL ACTUAL COVERAGE: ACTUAL GFA: 39% / 760.00m2 2022' · DOWN PIPES & ROOF DRAINAGE LOCATIONS ARE SUGGESTED ONLY AND BUILDER SHOULD ENSURE ADEQUATE STORMWATER FALL & DRAINAGE
GROUND LEVEL 33.92% / 658m2 · PDR TO HAVE MECHANICAL VENTILATION AS REQUIRED
FG FLOOR GULLY RH RAINHEAD FGL FINISHED GROUND LEVEL UPPER LEVEL 23.25% / 451m2 · ALL BASINS & BATHS TO HAVE OVERFLOWS · DRAINAGE SHOULD BE CONCEALED WITHIN SLAB WHERE NOTED.
PD PLUMBING DUCT FALL DIRECTION RL FINISHED LEVEL · FOR ALL LANDSCAPING REFER TO LANDSCAPING CONSULTANTS DETAILED DRAWINGS · FOR ALL WET AREAS, SET DOWN FLOOR CONSTRUCTION TO PROVIDE TILED FLOOR FLUSH WITH ADJOINING FFL, FALL TO WASTE, DROP SHOWER
8880 4500
D B
GARAGE WALL IN ACCORDANCE
WITH QDCC MEAN HEIGHT OF
NOT MORE THEN 3.5
349o01'30" / 20.000
SETBACK
358 o05' /
12 .703 349o01'30" / 34.270
1500
DASHED LINE OF PROPOSED LOCATION FOR
HT PROPOSED LOCATION FOR 10m OFFSET SEWER MAINTENANCE HOLE
GATE
DP SEWER MAINTENANCE HOLE
DP BICYCLE STORAGE FROM MHWS
SETBACK
LAWN STEPPERS FEATURE STONE WALL EXISTING SEWER
LAWN MAINTENANCE HOLE
1500
400mm DROPPED BULKHEAD HT DP HT
PD ALUMINUM STEPPERS
SCREENING
3400 FLOOR TO FLOOR, 18 RISERS FEATURE STONE SURROUND
@189mm W/ 17 TREADS @ 340 MID
W2 DP HT
POINT PLUS 20mm NOSING
70
GATE
1.3
SEWER
PLANTER
DP HT GRAVITY
STAIRWAY CONSTRUCTION
IN ACCORDANCE WITH
G W3
MAIN RL
OUTDOOR
NCC ABCB 11.2.2 SCREEN DAYBED DAYBED
0 TV BUILT-IN PD GAZEBO GAZEBO LAWN
.40 9 8 7 6 5 4 3 2 OUTDOOR BBQ
SEATING
L2
EXISTING SEWER 1
0
GATE
0
P'NTRY
MAINTENANCE HOLE
R TERRACE
2.7
PD SEWER
8250
LAWN SINK UP
GRAVITY
R L TILES LINE OF MHWS
CARPARK GARAGE MAIN STRIP DRAINS
SINK
CONCRETE EPOXY
BREAKFAST BAR
3100 CEILING
TILES
LIVING W4
SITTING POOL BALUSTRADE
POOL BALUSTRADE
C 300mm DROPPED BULKHEAD
TILES STRIP DRAINS C ENTERTAINMENT TILES
TO LOCAL COUNCIL
REQUIREMENTS
LINE OF TIMBER
PERGOLA ABOE
TO LOCAL COUNCIL
REQUIREMENTS
TILES
LINE OF
LEVEL
3000 CEILING D4 COURTYARD BAR 0
DN
.15
3000 CEILING DN
4 3 2 1
ABOVE
0 DINING
.70 L2
TILES
GARAGE DOOR OUTLINE GARAGE DOOR OUTLINE
DN
00 3 2 1
1 2
0 L2
COBBLESTONE 3000 CEILING
2.7 R 70
.70 1.3
1000
RL
CSD
G R
DEPTH 0.20
DEPTH 0.45
DEPTH 0.70
DEPTH 0.95
DEPTH 1.20
FG
IN-GROUND GAS L2 .7 00 DP
RL
GATE
G R 2 LINE OF LEVEL ABOVE PLANTER
RL
DN CONCRETE POST
3
1190 2 D2 W1 DP TV
STRIP DRAINS
STONE LINE OF 20mm REBATE LINE OF 20mm REBATE 1
FEATURE GD3 20 GD2 20 DP D3
LINE OF LEVEL ABOVE LINE OF RETAINING WALL
WALLS STRIP DRAINS DASHED LINE OF
FEATURE TIMBER
G POOL WET-EDGE
FEATURE STONE 5200 DP 5600 BEAMS ABOVE DASHED LINE DASHED LINE STONE
DASHED LINE OF
CLADDING OF ARCHWAY OF ARCHWAY FEATURE POOL TROUGH
FEATURE TIMBER FEATURE STONE TV FIREPLACE COLUMN
DRIVEWAY
DEPTH 0.45
BEAMS ABOVE
FEATURE STONE
PAVERS
PLANTER
0 DEPTH 1.40
ENTRY GATE .30 LINE OF LEVEL ABOVE RL 1.450
259 01'30" / 21.077
L2
ALUMINIUM
STONE
FENCE
R
o
FEATURE
LAWN STEPPERS WALLS LAWN STRIP DRAINS
FG
0
.65
TIMBER FG
STEPPERS PERGOLA
2 LIVING
D ABOVE
RL TILES LAWN
3000 CEILING
COURTYARD OUTDOOR
00 FRONT PATH ENTRY DOORS PAVERS D6
00
1.8
DEPTH 1.0
LAWN 2.7 LIVING
Section 4
RL 00 STRIP DRAINS STRIP DRAINS
RL
6000 SETBACK 2.7
TILES
DEPTH 0.50
RL 0 0
SITTING SPA POOL
2.7
1 2 3
FEATURE
DN D7 4.0 x 1.5 14.5 x 4.5 HT
FG
R L TILES
DEPTH 1.80
COLUMNS
GATE
LOW HEIGHT STONE LAWN
RETAINING WALL 50 STONE 50
DRIVEWAY 2.3 FEATURE 2.1 JETTY SHOWER
0 RL WALLS
RL
.10
DEPTH 1.0
PLANTER
2 0 PAVERS ALUMINIUM
RL .40
LAWN BUILT-IN
GATE FENCE
L2
SEATING
DEED
R LINE OF LEVEL FEATURE STONE
DRIVEWAY
FEATURE ABOVE
BOUN
LINE OF LEVEL FG
SLIDING GATE
TREE HT HT D1 ABOVE
DP SITTING
DARY
DISPLAY CABINET
DEPTH 0.45
COBBLESTONE STRIP DRAINS
DINING
BENCH SEAT
DEPTH 1.40
STORAGE
CONSOLE
RP90
00
RL 1.450
ENTRY .7
TILES
ALUMINIUM
DP
L2 3000 CEILING STRIP DRAINS
70 FENCE
1.3
TILES
1986
R DP 0 RL
3000 CEILING
.70
STRIP DRAINS POOL BALUSTRADE
D5
00 2 OUTDOOR TO LOCAL COUNCIL
00 RL
REQUIREMENTS
2.6 2.7
STEP FREE RAMPING
ALUMINUM
ENTRY INTO GARAGE DINING POOL WET-EDGE
RL
2 x 750 PIVOT
RL
SCREENING
TILES POOL TROUGH
DOORS
STONE
DASHED LINE FEATURE
DEPTH 0.45
DEPTH 0.95
DEPTH 0.20
DEPTH 0.70
DEPTH 1.20
A GARAGE A
GATE
OF ARCHWAY COLUMN
5600
SERVICES 6000 DASHED LINE OF PLANTER
HT LAWN
DRIVEWAY GD1 EPOXY
3100 CEILING
STEP FREE
ENTRY
UP LEVEL ABOVE 16 DN 900 D 1300 CSD DP LAWN
1 15 FG LINE OF LEVEL ABOVE
NEXT LEVEL PD
LINE OF 0 0 ELEVATORS -
SINK
2 14
00
LEVEL
2.7 3
ELTEC HLB
13
RL
ABOVE (SLIDING DOOR MS
.3 - XXL) TA SHAFT
L2
SEWER
4 12
1500
1800 DASHED LINE OF
R 5
LIFT 11
SINK
GRAVITY
MAIN KAYAK STORAGE
(180mm MINIMUM 1250 BELOW
STORAGE
PIT DEPTH) SINK
LINEN & COMM'S
6 10
0 W5
PDR LAUNDRY 0 KITCHEN
STAIRS 2.7
7 9
CISTERN
TILES
GARAGE
DOOR
8 VOID 8 TILES
2700 CEILING
TILES
2700 CEILING DRY
RL 3000 CEILING
9 STAIRCASE LANDING 7 G
70
OUTLINE FEATURE COOKTOP & OVEN DN LINE OF MHWS
1.3
BUILT-IN
ACK
LAWN 0 00
.70
STAIRWAY CONSTRUCTION SEATING
2.7
3 2 1
DP HT L
1500
WM
00 BBQ
IN ACCORDANCE WITH
2 G R
RL RL 2.7
NCC ABCB 11.2.2
GATE
SETB
STEPPERS R L TILES DASHED LINE OF 10m
TUB
Section 5
PD OFFSET FROM MHWS
3400 FLOOR TO FLOOR, 18 RISERS W8 PLANTER
ALUMINUM
SCREENING
@189mm W/ 17 TREADS @ 340 MID
POINT PLUS 20mm NOSING
SINK TERRACE
LAWN
W7 DP D12 LINE OF PANTRY TILES
CONVERSATION
DROPPED
50
GATE
TILES
BATH 1 2.1
CEILING
STEPPERS
2700 CEILING
0 PIT
RL
LINE OF RETAINING WALL
.70
W6 PLANT D10 TILES D8 DN DN
COBBLESTONE
182 o30 2
RL
SINK EPOXY 3000 CEILING 4 3 2 1
' / 52.3 3 2 1
04 STEPPERS DRYING AREA 0
2700 CEILING
.40
L1
SHOWER
4190 3580 D11
HT
DP DP
.7 00 CISTERN FG
STRIP DRAINS
R
0 L2 50
.70 .3
FG
R
L2 OUTDOOR SURFBOARD STORE L1
PLANTER
R TERRACE SHOWERS STORE 0 BUILT-IN
R
.70
EPOXY
D9 SEATING
L2
TILES 3100 CEILING
GD4
ACK
LINE OF
LEVEL R 0
.33
1500
ABOVE 3 DN
1
SETB
DP HT 2
R L
1
FEATURE DASHED LINE OF
STEPPERS LAWN
STONE WALL KAYAK STORAGE
BELOW
STEPPERS
GATE
STEPPERS
SEWER
GRAVITY
MAIN
180 o00'
B / 21.195
GROUND PLAN
PAUL CLOUT DESIGN GENERAL NOTES:
Suite 3, 44 MARY STREET, NOOSAVILLE Use written dimensions only. DO NOT scale drawings. Contractors to verify all dimensions on site prior to REVISION DATE REV DESCRIPTION
CLIENT NAME: Pickering, Brendan & Angelique
PO BOX 152, NOOSAVILLE, QLD 4566. commencing works. Site location is Category W41 or to engineer's requirements. These drawings are to be SITE ADDRESS: 92 Hilton Terrace, Noosaville 15/05/2025 A CLIENT ISSUE
BSA LICENCE: 1066417 read in conjunction with engineer's design and details, the accompanying building specification and schedule 06/01/2026 B SPS ISSUE
PH: (07) 5440 5388
of finishes. If in doubt, please request clarification. DO NOT ASSUME.
@COPYRIGHT PAUL CLOUT DESIGN PTY LTD.
DRAWING TITLE:
STAGE:
Ground Plan
Council Drawings
C 14/08/2026 C COUNCIL ISSUE
[email protected]
www.paulclout.com
NOT FOR CONSTRUCTION SCALE: 1:100 ON A1 DRAWING No. 02.0
The text continues on section 6.
Used in these records
Council Drawings - 92 Hilton Terrace, Noosaville (Revision C).pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.