KEY SITE REQUIREMENTS NOTES
CSD CAVITY SLIDING DOOR MFR METAL FLAT ROOF SD SMOKE DETECTOR SITE 1939.64m2 · ALL TOILET DOORS TO HAVE LIFT OF HINGES · LIVABLE HOUSING DESIGN STANDARD 2022 COMPLIANT BATHROOM TO INCLUDE MINIMUM 820mm CLEAR OPENING, HOBLESS / STEP FREE ENTRY,
· RL'S ARE ASSUMED ONLY AND SHALL BE VERIFIED BY BUILDER PRIOR TO NO LIP GREATER THEN 5MM. REFER TO figure A4(3) ON QDC MP4.5 FOR FURTHER DETAILS. ENSURE RE-INFORCING IS DONE AS PER PART 6 OF
D DOOR MPR METAL PITCHED ROOF HT HOSE TAP ALLOWED COVERAGE: 40% / 775.85m2 ALLOWED GFA: 40% / 775.85m2 COMMENCEMENT OF SITE WORKS LIVABLE HOUSING CODE.
N
GD GLASS DOOR CONCRETE FLAT ROOF G GAS POINT · ALL BASINS & BATHS TO HAVE OVERFLOWS · ALL RELEVANT PAHTS & FLUSH TRANSITIONS AS REQUIRED BY NCC LIVABLE HOUSING CODE TO BE INSTATED TO CODE BY BUILDER. VOS WITH
FR
· PDR TO MEET REQUIREMENTS STATED IN THE 'LIVABLE HOUSING DESIGN STANDARD DESIGNER & CERTIFIER IF REQUIRED.
W WINDOW DP DOWN PIPE NGL NATURAL GROUND LEVEL ACTUAL COVERAGE: ACTUAL GFA: 39% / 760.00m2 2022' · DOWN PIPES & ROOF DRAINAGE LOCATIONS ARE SUGGESTED ONLY AND BUILDER SHOULD ENSURE ADEQUATE STORMWATER FALL & DRAINAGE
GROUND LEVEL 33.92% / 658m2 · PDR TO HAVE MECHANICAL VENTILATION AS REQUIRED
FG FLOOR GULLY RH RAINHEAD FGL FINISHED GROUND LEVEL UPPER LEVEL 23.25% / 451m2 · ALL BASINS & BATHS TO HAVE OVERFLOWS · DRAINAGE SHOULD BE CONCEALED WITHIN SLAB WHERE NOTED.
PD PLUMBING DUCT FALL DIRECTION RL FINISHED LEVEL · FOR ALL LANDSCAPING REFER TO LANDSCAPING CONSULTANTS DETAILED DRAWINGS · FOR ALL WET AREAS, SET DOWN FLOOR CONSTRUCTION TO PROVIDE TILED FLOOR FLUSH WITH ADJOINING FFL, FALL TO WASTE, DROP SHOWER
8880 4500
D B
GARAGE WALL IN ACCORDANCE
WITH QDCC MEAN HEIGHT OF
NOT MORE THEN 3.5
349o01'30" / 20.000
SETBACK
358 o05' /
12 .703 349o01'30" / 34.270
1500
DASHED LINE OF PROPOSED LOCATION FOR
HT PROPOSED LOCATION FOR 10m OFFSET SEWER MAINTENANCE HOLE
GATE
DP SEWER MAINTENANCE HOLE
DP BICYCLE STORAGE FROM MHWS
SETBACK
LAWN STEPPERS FEATURE STONE WALL EXISTING SEWER
LAWN MAINTENANCE HOLE
1500
400mm DROPPED BULKHEAD HT DP HT
PD ALUMINUM STEPPERS
SCREENING
3400 FLOOR TO FLOOR, 18 RISERS FEATURE STONE SURROUND
@189mm W/ 17 TREADS @ 340 MID
W2 DP HT
POINT PLUS 20mm NOSING
70
GATE
1.3
SEWER
PLANTER
DP HT GRAVITY
STAIRWAY CONSTRUCTION
IN ACCORDANCE WITH
G W3
MAIN RL
OUTDOOR
NCC ABCB 11.2.2 SCREEN DAYBED DAYBED
0 TV BUILT-IN PD GAZEBO GAZEBO LAWN
.40 9 8 7 6 5 4 3 2 OUTDOOR BBQ
SEATING
L2
EXISTING SEWER 1
0
GATE
0
P'NTRY
MAINTENANCE HOLE
R TERRACE
2.7
PD SEWER
8250
LAWN SINK UP
GRAVITY
R L TILES LINE OF MHWS
CARPARK GARAGE MAIN STRIP DRAINS
SINK
CONCRETE EPOXY
BREAKFAST BAR
3100 CEILING
TILES
LIVING W4
SITTING POOL BALUSTRADE
POOL BALUSTRADE
C 300mm DROPPED BULKHEAD
TILES STRIP DRAINS C ENTERTAINMENT TILES
TO LOCAL COUNCIL
REQUIREMENTS
LINE OF TIMBER
PERGOLA ABOE
TO LOCAL COUNCIL
REQUIREMENTS
TILES
LINE OF
LEVEL
3000 CEILING D4 COURTYARD BAR 0
DN
.15
3000 CEILING DN
4 3 2 1
ABOVE
0 DINING
.70 L2
TILES
GARAGE DOOR OUTLINE GARAGE DOOR OUTLINE
DN
00 3 2 1
1 2
0 L2
COBBLESTONE 3000 CEILING
2.7 R 70
.70 1.3
1000
RL
CSD
G R
DEPTH 0.20
DEPTH 0.45
DEPTH 0.70
DEPTH 0.95
DEPTH 1.20
FG
IN-GROUND GAS L2 .7 00 DP
RL
GATE
G R 2 LINE OF LEVEL ABOVE PLANTER
RL
DN CONCRETE POST
3
1190 2 D2 W1 DP TV
STRIP DRAINS
STONE LINE OF 20mm REBATE LINE OF 20mm REBATE 1
FEATURE GD3 20 GD2 20 DP D3
LINE OF LEVEL ABOVE LINE OF RETAINING WALL
WALLS STRIP DRAINS DASHED LINE OF
FEATURE TIMBER
G POOL WET-EDGE
FEATURE STONE 5200 DP 5600 BEAMS ABOVE DASHED LINE DASHED LINE STONE
DASHED LINE OF
CLADDING OF ARCHWAY OF ARCHWAY FEATURE POOL TROUGH
FEATURE TIMBER FEATURE STONE TV FIREPLACE COLUMN
DRIVEWAY
DEPTH 0.45
BEAMS ABOVE
FEATURE STONE
PAVERS
PLANTER
0 DEPTH 1.40
ENTRY GATE .30 LINE OF LEVEL ABOVE RL 1.450
259 01'30" / 21.077
L2
ALUMINIUM
STONE
FENCE
R
o
FEATURE
LAWN STEPPERS WALLS LAWN STRIP DRAINS
FG
0
.65
TIMBER FG
STEPPERS PERGOLA
2 LIVING
D ABOVE
RL TILES LAWN
3000 CEILING
COURTYARD OUTDOOR
00 FRONT PATH ENTRY DOORS PAVERS D6
00
1.8
DEPTH 1.0
LAWN 2.7 LIVING
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records