Appendix D - Visitor Accommodation Code · 132007.2446.03
Attached to the e-mail Other Change application (Extension of Existing Visitor Hostel - 21 Beds) - 132007.2446.03.
Proposal Report: Other Change to a Development Approval for Visitor Accommodation Type 4 Conventional (hostel accommodation) over Lot
163 on RP897370 and Lot 164 on RP94566 and located at 102 and 106 Pacific Avenue, Sunshine Beach
Column 1 Column 2 Column 3
Specific Outcomes Probable Solutions (if code assessable) Compliance
than on the perimeter of the premises; and or the private open space of adjoining
b) avoiding overlooking of the windows or residential premises which are less than 12m
private open space of adjoining properties away.
Kitchen, bathroom and dining facilities
O41 All guests and staff have access to— No solution provided. Complies - new rooms have ensuites and
a) internal bathrooms and sanitary facilities; access to existing common facilities.
and
b) common kitchen and dining facilities.
Kitchen and dining
O42 Kitchen and dining areas are large S42.1 Kitchen and dining areas are not less Complies – Existing kitchen is able to cater
enough to accommodate all occupants and than 5% of the hostel’s total gross floor area. for additional patrons. Minor extension to
have adequate kitchen and dining facilities. refrigeration required.
Common rooms
O43 A common room, sufficient in size to S43.1 A common room with a minimum floor Complies – Existing common areas and new
accommodate 60% of occupants at any one area of not less than 7% of the visitor cinema and outdoor smoking area (DOSA)
time, is provided. hostel’s total gross floor area is provided; sufficient to cater for patrons of the site.
AND
S43.2 If the visitor hostel has a restaurant or
café, it is of a size to accommodate 50% of
the total occupants at any one time and is no
less than 5.5% of the total gross floor area.
Communal sitting areas
O44 Comfortable and useable outdoor sitting S44.1 The outdoor sitting area has a Complies – communal area in the centre of
area is provided which receives natural minimum area of 8% of the hostel’s total the site and includes gardens and sitting
sunlight and breezes. gross floor area and is oriented towards the areas.
north.
Reception areas
O45 A reception area marks the entrance of S45.1 The reception area has a minimum Complies – existing reception area well
the hostel and is clearly visible and floor area of 12m2 and is visible from the signed and weatherproof.
weatherproof. street; AND
S45.2 The reception area is undercover
providing shelter from inclement weather.
Laundry and clothes drying facilities
O46 Visitors and staff have access to S46.1 A laundry provided on the premises Complies – existing laundry able to be
adequate laundry and clothes drying facilities has a minimum floor area of 3% of the visitor utilised and sufficient to cater for patrons.
on-site. hostel’s total gross floor area; AND
S46.2 An outdoor clothes drying area
receiving unrestricted sunlight for at least two
hours per day is provided on-site and is
accessible for the use of guests.
Vehicle parking and access
O47 The operation of a visitor hostel avoids No solution provided Complies – Large buses do not service the
the parking of buses that are associated with site. Flashpackers has an existing mini bus
the use, and with a capacity of 30 persons of that collects patrons form the Noosa Junction
more, within any street lower than a collector bus depot.
road status.
Page | 4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix D - Visitor Accommodation Code.pdfRelated documentApplication case desk ↗
About this file
- File size
- 29 KB (small file)
- File type
No other editions are linked here.