Information Request OPW17/0562

of 1

Text shows just the words. Original shows the document exactly as it was published.

Officer: 	Mark Lewis
Direct Telephone: 	07 53296290
Our Reference:	OPW17/0562
Your Reference:	RAP17/0008
15 November 2017
GA Swanepoel
18 Depper St
SUNSHINE BEACH  QLD  4567
[email protected]
Dear Sir
Information Request
Planning Act 2016
I refer to your application and advise that Council requires further information to satisfactorily assess the proposal.
application details
Application No.	OPW17/0562
Street Address:	7 Warana St Noosa Heads Qld 4567
Real Property Description:	Lot 4 RP 73349 No related Land
Planning Scheme:	The Noosa Plan (3 July 2017)
INFORMATION REQUIRED
The information requested is set out below:
Issue
The submitted design plan indicates that a 60mm depth of flow in the kerb and channel is the maximum achievable with the design. This maximum depth of flow is less than that required by Council’s standard drawing RS-050 (refer note 11 on RS-050) and Council has concerns with the potential for stormwater runoff in more significant events to leave the road formation and travel down the proposed driveway and inundate the subject site and the adjoining property.
Information Required
Provide amended drawings that are in accordance with Council’s standard drawing RS-050 and provide the required high point above the kerb invert. It is noted that this may require amendment to the design floor level of the proposed garage. Alternatively provide justification for any reduction in the level difference and demonstrate that runoff will not adversely affect the subject site or the adjoining property. The design and comments must be provided by a Registered Professional Engineer of Queensland (RPEQ)
Issue
The submitted site plan does not indicate the extent of filling/batters required within the road reserve to transition to the existing surface levels.
Information Required
Provide amended drawings that indicate the extent of filling/batters required within the road reserve to transition to the existing surface levels. The filling/batters must not:
create any trip hazards in the road reserve,
direct additional runoff on to any adjoining property or
cause additional ponding of stormwater in the road reserve or any adjoining property
Please note that private retaining structures (walls) are not permitted in the road reserve
due date for response to information request
The due date for providing the requested information is 15 February 2018. Please advise Council of your response to this information request in accordance with section 13 of the Development Assessment Rules.
If you do not provide a response before the due date, it will be taken as if you have decided not to respond to the information request and Council will continue with the assessment of your application.
other details
You can follow the progress of this application online at www.noosa.qld.gov.au. The “Online Services” page can be accessed via "Quick Links" on the left hand side of the screen.

Should you have any further queries in relation to the above, please do not hesitate to contact me on the number above.
Yours faithfully,

Mark Lewis
Coordinator - Engineering

[word/footer1.xml]
Page 2 of 2

[word/footer2.xml]
PO Box 141		P. (07) 5329 6500	[email protected]	
	TEWANTIN  QLD  4565	F. (07) 5329 6501	www.noosa.qld.gov.au
				Page 1 of 2

[word/header1.xml]
3

Used in these records

About this file

File size
79 KB (small file)
File type
DOCX

No other editions are linked here.

Original file

Log in to download the original file

Information Request OPW17_0562.docx · 79 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.