Council archive · source document
Minor Change Existing Approval 132001 210327 1 · 132001.210327.1
4. ASSESSMENT MANAGER CONDITIONS
Building
1. There is to be no uncontrolled discharge of water onto the slope.
2. Stripping of vegetation for construction purposes should be minimised. If vegetation is
destroyed it should be reinstated immediately after construction is completed.
3. Additional load due to fill, construction equipment or stockpiled materials should not be
located on the dune slope. Filling in the open space area is to be avoided.
4. The use of vibratory equipment of any kind is not permitted to be used, including vibrating
rollers, the use of vibrating installation techniques for sheet piling and other construction
vibrations caused by excavating, earthmoving or demolition machinery or other similar
construction techniques.
Land Development
5. A Registered Professional Engineers Queensland (REPQ) shall design all foundations for
the proposed building extensions taking into account that the site is located in a Sand Dune
Problem Area and that special foundations may be necessary.
6. Existing vegetation on site shall be retained except where removal is required to enable
construction of the proposed extensions. In this regard care shall be taken to minimise any
disturbance to the vegetation.
7. To minimise the risk of dunal instability during construction, no heavy machinery or
equipment is to be used to construct the proposed building extensions.
8. On completion of construction, dense deep-rooted vegetation cover, using approved species,
shall be established on any exposed soil in order to minimise the risk of any soil movement
or erosion.
9. At the completion of construction, a RPEQ shall certify that all works have been carried out
in accordance with good engineering practices and that both the extensions and the site are
stable and safe against failure.
Land Use
10. Development authorised by this approval must be undertaken generally in accordance with
the Approved Plans listed in the tables below. The plans must be amended to incorporate
the amendments listed within the table below and resubmitted to Council prior to the issue
of any Development Permit for Building Works*
Plan No. Rev. Plan/Document Name Date
2003 DD6 Guest Floor Plan -Prepared by Sealand Architects 29.10.24
2004 DD6 Garage Floor Plan - Prepared by Sealand Architects 29.10.24
2005 DD6 Office Floor Plan - Prepared by Sealand Architects 29.10.24
Annotated by Council
3000 DD6 East Elevation - Prepared by Sealand Architects 29.10.24
3001 DD6 West Elevation - Prepared by Sealand Architects 29.10.24
3002 DD6 North Elevation - Prepared by Sealand Architects 29.10.24
3003 DD6 South Elevation - Prepared by Sealand Architects 29.10.24
4000 DD6 Section A - Prepared by Sealand Architects 29.10.24
Page 2 of 6
Document Set ID: 23391709
Version: 3, Version Date: 09/12/2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Minor Change Existing Approval 132001 210327 1.pdfRelated documentApplication case desk ↗
About this file
- File size
- 152 KB (small file)
- File type
No other editions are linked here.