                                                 9:00am and 3:00pm on                      grey tint glass;
Editor's note​—Provisions for sill               any day of the year;                  ●   The upper level has a
height, glazing, screening and window
                                            3. incorporate       fencing,                  portion of solid balustrade
openings are to improve the residential
amenity for occupants. Thermal                 landscaping           and                   adjacent to the planter
performance       requirements     are         screening to mitigate                       beside the lift core;
contained in Queensland Development
                                               impacts on adjoining                    ●   The stairwell has a fire
Code MP4.1 Sustainable Buildings.                                                          rated glass brick window.
Energy efficiency requirements are             residential uses.
contained in the National Construction
Code.                                     Editor's note​— refer to ​figure AP3-1A
                                          and ​figure AP3-2A

                                          AO20.2
                                          Transparent      doors     and
                                          windows are designed and
                                          located so they do not directly
                                          face transparent doors or
                                          windows or the ​private open
                                          space areas of other dwellings
                                          within 10 metres;

                                          AO20.3
                                          Where windows, balconies,
                                          terraces, verandahs or decks
                                          overlook or have the potential
                                          to overlook the ​private open
                                          space of nearby properties or
                                          view into habitable room
                                          windows within 10 metres:
                                            1. windows have a sill
                                                height of not less than
                                                1.7      metres       above
                                                finished floor level;
                                            2. windows      and  other
                                               openings            are
                                               permanently screened to
                                               a minimum height of 1.7
                                               metres       to   avoid
                                               overlooking;
                                            3. windows and doors use
                                               translucent glazing to
                                               obscure views; or
                                            4. windows or balconies are
                                               offset by 45 degrees or
                                               more.


PO22                                      AO22.1                                    Please refer to Earthworks and
Development:                              For landscape amenity reasons,            Piling Plan and Site Silt and
                                          cut or fill is less than 1.5              Sediment Erosion Plan prepared
 1. has minimal impact on the             metres in depth relative to the           by SCG Consulting Engineers.
    natural landform of the               ground level​.
    site​;
 2. does not lead to erosion or
    the transport of sediments
    off ​site​; and


                                                                                                                14

Used in these records

About this file

File size
788 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Planning Report.pdf · 788 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.