Council archive · source document
RFI - Revised Engineering Plans · MCU24/0153
Plans and drawings: the text below has words only, no drawings.
Original PDF page 4, section 1. The text section number identifies this passage in the reader.
S
S
REFER TO BASEMENT PLAN
FOR STORMWATER SYSTEM
S
>
>
UNDER BASEMENT LEVEL
S
3-3
>
>
2.0m x 2.5m x 1.0m DEEP CONCRETE
S
DETENTION TANK. MIN. 5.0m3
REQUIRED STORAGE VOLUME.
S
>
>
S
>
>
S
1-2
>
>
6-1
S
S
>
>
S
>
REFER TO BASEMENT LAYOUT
>
S
DRG C011
4-3 1-5
>
S
S
REFER TO SHEET 017 FOR VEHICLE
>
TRACKING LONGITUDINAL SECTION.
S
>
S
>
S
45.4
S
3-3
>
45.6
S S
1-2
45.8
8-1
S
>
0
46.
6-1
.96
2
46.
4 3 T
4
>
46.
7-1 EN
6
S
M
46.
.6 3 E 4-3
43 S
8
46.
BA
0
TO
47.
CONNECT TO EXISTING
AY
2
STORMWATER INLET PIT
47.
S
W REFER TO ARCHITECTURAL
4
47.
E
IV PLANS FOR BUILDING DESIGN
6
DR
47.
8
47.
S S S
8-1
0
48.
ENLARGEMENT 6
2
.9
48.
43.4
43
7-1
4
SCALE 1:50 ACO K300 KLASSIKDRAIN .63
48.
43
43.6
OR SIMILAR APPROVED 6
48.
TO CONNECT TO 1-4
44 .8
44 .0
43
44 .2
44.6.4
8
48.
45 .8
45 .0
44
45 .2
0
49.
45.6.4
5-1 REFER TO
ENLARGEMENT
49.2
2-1
45.8
EXISTING POWER POLE TO BE RELOCATED
46.0
49.4
OR MAIN TO BE RELOCATED UNDERGROUND.
SUBJECT TO ENERGEX APPROVAL. 1-1
46.2
46.4
REINSTATE VERGE AND
49.6
46.6
KERB TO MATCH EXISTING
46.8
46.6 EXISTING CONTOURS
PROPOSED VEHICLE CROSSOVER 4-1
EXISTING BUILDING
47.0
IN ACCORDANCE WITH IPWEA STD \ \ \ \ \ \ \ \ \ \ \
5m
DRG RS-049 & RS-050
EXISTING KERB AND CHANNEL
47.2
VISITORS PARKING
EXISTING FENCE
47.4
W
47.6
T EXISTING TELSTRA
W
47.8
OE EXISTING OVERHEAD ELECTRICAL
4m
48.0
49.6
W
W EXISTING WATER
S EXISTING SEWER
49.6
48.2
ACO K100 KLASSIKDRAIN WITH
W EXISTING TELSTRA PIT
HEELSAFE GRATE OR SIMILAR
5m
48.4
APPROVED TO CONNECT TO WM EXISTING WATER METER
STRUCTURE 2-1
W
48.6
0m 46.0 PROPOSED CONTOURS
1.5
2.5
m
48.8
PROPOSED 2.5m WIDE ADJACENT BOUNDARY
W
CONCRETE FOOTPATH
PROPOSED BOUNDARY
49.0
EL
AN
DA
W PROPOSED STORMWATER PIPE
49.2
ST
RE
PROPOSED STORMWATER PIT
ET
W RETAINING WALL (BY OTHERS)
5 m
0.4
> > > PROPOSED SWALE
PROPOSED CONCRETE PAVEMENT
PROPOSED 1.5m WIDE
CONCRETE FOOTPATH
PROPOSED FOOTPATH
PROPOSED BITUMEN PAVEMENT
MATCH NEATLY TO PAVEMENT CUTBACK EXTENT
EXISTING FOOTPATH
.53
49
North Point Approved Project Address Sheet Title
SITEWORKS OVERALL LAYOUT GROUND
E WHITMORE 51 ELANDA STREET SUNSHINE BEACH QLD
N RPEQ 31423
For and on behalf of RECOR Pty Ltd.
Scale 1.0 0 1.0 2.0 ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SCALE (metres) SUNSHINE COAST | BRISBANE | SYDNEY
1 0
1 : 50 (FULL SIZE)
1 2 3 4 5
www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE A1
A 21/03/25 ISSUE FOR APPROVAL TVZ AY SCALE (metres) COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This Project Number Sheet Number Revision
010
1 : 100 (FULL SIZE)
A
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK in the revision description. 20240127
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Revised Engineering Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.