Part 18 of 37 Appendix 16 - Contaminated Land Assessment MCU12/0208
Very large file (44.6 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
www.access.gs +GIL. 1
SlJT1-ERlAN)
RP893393). The lots within the site were not listed
on the EMR or the ClR. Copies of these searches
are included in Appendix C.
5.4 Site reconnaissance and anecdotal
information
In May 2012, G&S conducted a telephone
interview with the current caretaker of lot 53 on
SP163571. The caretaker indicated that the
storage shed within lot 53 on SP163571 was
constructed in the early 2000’s. The storage shed
has been used to house farm machinery,
equipment and agricultural chemicals, such as the
herbicides ’Roundup’and ’Taskforce’.
The Caretaker also informed G&S that an above-
ground fuel storage tank (AST)exists within the
storage shed. It is understood the AST stores up
to 800l of diesel fuel and is approximately 7 years
old. He indicated that the AST is in good condition
with no obvious leaks.