Council archive · source document
Viridian Stage 3 Documentation A3 [As Published] · 142008.256
Very large file (63.1 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Original PDF page 2, section 1. The text section number identifies this passage in the reader.
LANDSCAPE ARCHITECT
SURFACE FINISHES LEGEND
BLOCK WORK RETAINING WALL. REFER TO ENGINEERS PLANS
PA PLANTING AREA
SHOTCRETE WALL ( SOIL NAIL WALL ). REFER TO ENGINEERS PLANS
UT UNDERCROFT TREATMENT AREA VERTICAL BORED PIER WALL. REFER TO ENGINEERS PLANS
VERTICAL GABION EARTH REINFORCED WALL. REFER TO ENGINEERS PLANS
RP REVEGETATION AREA ONLY BY
OTHERS (NO GO ZONE) CONCRETE RETAINING WALL. REFER TO ENGINEERS PLANS
GU GRAVEL UNDERCROFT BUFFER ZONE EXCLUSION FENCE. REFER TO ENGINEERS PLANS CLIENT
SITE BOULDERS - EXISTING TO BE USED ON SITE. PROPOSED GABION WALL& DRAIN. REFER TO ENGINEERS PLANS
LOCATION TO BE CONFIRMED BY LANDSCAPE
ARCHITECT. REFER SPECIFICATION
EXISTING GABION WALL. REFER TO ENGINEERS PLANS
P1 PAVEMENT TYPE 1: REFER TO SPECIFICATION.
PROPOSED TABLE DRAIN. REFER TO ENGINEERS PLANS
P2 FIRE MAIN. REFER TO ENGINEERS PLANS
PAVEMENT TYPE 2: REFER TO SPECIFICATION.
WATER MAIN - HIGH LEVEL SUPPLY. REFER TO ENGINEERS PLANS KEY PLAN
P3 PAVEMENT TYPE 3: REFER TO SPECIFICATION.
WATER MAIN - LOW LEVEL SUPPLY. REFER TO ENGINEERS PLANS
P4 PAVEMENT TYPE 4: REFER TO SPECIFICATION. SEWER LINE. REFER TO ENGINEERS PLANS
STORM WATER LINE. REFER TO ENGINEERS PLANS
P5 PAVEMENT TYPE 5: REFER TO SPECIFICATION.
FIRE PUMP FEED LINE. REFER TO ENGINEERS PLANS
P6 PAVEMENT TYPE 6: REFER TO SPECIFICATION. TEMPORARY CUT/FILL BATTERS. REFER TO ENGINEERS PLANS NOTES
PAVEMENT TYPE 7: KERB/VEHICLE PAVING TO BE
P7 EXISTING TREE TO BE RETAINED
CONFIRMED. REFER TO SPECIFICATION.
P8 PAVEMENT TYPE 8: COPING TO RESORT POOL. REFER
TO SPECIFICATION.
GENERAL NOTES:
P9 PAVEMENT TYPE 9: COPING TO LOOKOUT POOL.
1. All service locations shown are indicative only. Refer to to engineers
REFER TO SPECIFICATION.
drawings for more detail.Confirm service locations on site prior
to any construction.
P10 PAVEMENT TYPE 10: REFER TO SPECIFICATION.
2. Refer to Engineers drawings for finished surface levels unless shown
on Landscape Drawings.
P11 PAVEMENT TYPE 11: REFER TO SPECIFICATION. 3. All setout on site to be by builder and confirmed by landscape architect prior to any construction.
4. For lighting refer to Electrical Engineers Drawings
P12 PAVEMENT TYPE 12: REFER TO SPECIFICATION.
5. All trees within / adjacent to vehicle sightlines are to be set out on
site prior to installation and approved by the superintendent and traffic engineer.
P13 PAVEMENT TYPE 13: REFER TO SPECIFICATION. 6. Final planting location and numbers subject to final services locations
7. All concrete footpaths and road surfaces by builder. Refer to
Landscape documentation for colour and finishes only.
AC ASPHALT. REFER ENGINEERS SPECIFICATION.
8. All swales and storm water pits that perform a stormwater function onsite are to be installed by the
civil / builder contractor to engineers specification. All aesthetic landscape swales are to be approved
W1 WALL TYPE 1: WET STACKED YELLOW STONE WALL. by the consulting engineers and installed by the builder. Layout to be approved by landscape architect
REFER TO SPECIFICATION. in conjunction with site engineer.
9. Undercroft treatment area either planting, gravel or mulch to be confirmed on site. No planting
W2 WALL TYPE 2: RACKED BLOCKWORK WALL RENDERED. where site conditions won't allow natural growth.
REFER TO SPECIFICATION.
S1 SEAT TYPE 1: REFER TO SPECIFICATION.
S2 BIKE RACK: REFER TO SPECIFICATION. SHEET DETAILS
1m 0m 1m 2m 5m
S3 BIN TYPE 1: REFER TO SPECIFICATION.
SCALE: 1:100 @ A1 size sheet
S4 NESTING BOXES: REFER TO SPECIFICATION.
Do not scale from this drawing.
Verify all dimensions on site prior to construction.
All dimensions are in millimetres unless otherwise noted.
AMENDMENT / ISSUE REGISTER
BALUSTRADE TYPE 1: VEHICULAR GRADE BALUSTRADE,
REFER TO ENGINEER'S DETAIL Issue Description Date Sign
P1 PRELIMINARY REVIEW 18.12.07
BALUSTRADE TYPE 2: TIMBER AND STAINLESS STEEL.
REFER TO SPECIFICATION. OP1 OPERATIONAL WORKS ISSUE 16.01.08
OP1 OPERATIONAL WORKS ISSUE 01.02.08
P2 PRELIMINARY REVIEW 05.02.08
BALUSTRADE TYPE 3: TIMBER. REFER TO
T1 TENDER ISSUE 06.02.08
SPECIFICATION.
OP1 OPERATIONAL WORKS ISSUE 12.02.08
FENCE TYPE 1 - RESORT POOL FENICING TO
ARCHITECT'S DETAIL
PROJECT
FENCE TYPE 2 - BLACK POWDERCOATED POOL FENCE
(LOOKOUT AND LAP POOL). REFER TO SPECIFICATION. VIRIDIAN
STAGE 3
FENCE TYPE 3 - FENCE TO BE CONFIRMED SURROUNDS
MANAGERS UNIT. REFER TO SPECIFICATION.
SWALE TYPE 1 - REFER TO DETAILS
TITLE
LEGEND
SWALE TYPE 2
DRAWING INFORMATION
Design Drawn Date Scale Checked
DH JL 12.02.08 1:100
Project No. Drawing No. Issue
0551 2059.02 L-LE-002 OP1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Viridian Stage 3 Documentation A3 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 63.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.