Council archive · source document
001511C5.001
Text sections not matched to the original PDF pages. See original document to check page numbers.
Table Error! No text of specified style in document.-1 — For All Residential Uses
column 1 column 2 Column 3
Specific Outcomes Probable solutions (if code assessable) Compliance
fEffectsiofuse“e 200 es
Electricity supply infrastructure
‘O1 The development does not adversely impact | $1.17 No solution provided Complies
Lo, on existing or future electricity supply .
infrastructure; . .
AND ° . ; ;
O02. All uses and works maintain an adequate $2.1 Development for uses adjacent to or
safe distance from electrical infrastructure within 50m of an existing electricity substation
including substations, overhead powerlines, power | incorporates noise attenuation measures to : .
poles and transformers. mitigate noise impacts;
AND oo
$2.2 Buildings and structures (including ’
. swimming pools, sheds, tennis courts or . i,
outbuildings) are not constructed under a
overhead electricity transmission lines, or within
: electricity easements;
AND :
. ; ; $2.3A minimum separation distance is : .
maintained from the electricity transmission line .
. |, to the closest boundary of habitable buildings
. and child activity areas, as follows— , '
‘ “ a) 20m for transmission lines up to 132kV; .
b) 30m for transmission lines between 133kV .
and 275kV; and .
- c) 40m for transmission lines greater than . .
275kV. :
{Environmentally Sustainable BuildingiDesign'. 72:2) 5 "le Tek. Ue See A ee ee
Hot Water Systems , a
O3 Hot water systems are installed and operated | $3.7 All hot water systems installed are— Conditions may be imposed if required
to support the efficient use of natural resources a) solarsystems; or. : -; ‘
and minimise consequent pollution such as . b) electric heat pump systems; or :
greenhouse gas emissions. c) natural gas or LPG systems; or
d) any combination of a), b) orc). :
Water supply and conservation | ." .
O04 On-site water storage is designed and $4.7 If in a designated rainwater tank area as Water tanks will be provided.at rear of site.
operated to support the efficient use of water; identified in Map 1 of Schedule 8, residential. .
uses that qualify as class 1A or 1B structures
* This does not apply to buildings which qualify as Class 1A or 1B structures under the Building code of Australia .See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
001511C5.001.pdfRelated documentPublic source context ↗
07/0799 - MCU - Multiple Housing Type 2 Duplex [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.