   NOOSA COUNCIL
  APPROVED PLANS
OPW14/0197 3 OCT 2014


[OCR of page images]
 

 

 

STRUCTURE
NAME

IN/R

OUT/R

1/RW3

2/RW3

B/RW3
(OUT/RW3

W/RW4
2/RW4
3/RW4

4/RW4
5/RW4
OUT/RW4,
V/RWS
2/RWS

3/RWS
4/RW5S
S/RWS
G15/P

GIT/S

J
G18/T
2/)
GI9/U
3/M

G20/V
3/M

 

 

STRUCTURE
DESCRIPTION

600 x 600 FIELD INLET

 

 

375mm DIAMETER

CONCRETE HEADWALL

600 x 600 FIELD INLET
ON 1050 DIA. MANHOLE

100 x 600 FIELD INLET
ON 1050 DIA. MANHOLE

00 x 900 FIELD INLET

600 x 600 FIELD INLET
ON 1050 DIA, MANHOLE
600 x 600 FIELD INLET
ON 1050 DIA. MANHOLE
600 x 600 FIELD INLET

ON 1050 DIA. MANHOLE

550 DIA. ROOFWATER MANHOLE

600 x 600 FIELD INLET
ON 1050 DIA. MANHOLE
600 x 600 FIELD INLET
ON 1050 DIA, MANHOLE
375mm DIAMETER

CONCRETE HEADWALL
600 x 600 FIELD INLET

600 x 600 FIELD INLET
ON 1050 DIA. MANHOLE
600 x 600 FIELD INLET
ON 1050 DIA, MANHOLE
STD NSC SINGLE GULLY

STD NSC SINGLE GULLY

1050mm DIAMETER - REFER DETAIL
1050mm DIAMETER - REFER DETAIL

STD NSC MANHOLE
STD NSC SINGLE GULLY
STD NSC MANHOLE
STD NSC SINGLE GULLY
STD NSC MANHOLE

1800mm DIAMETER - REFER DETAIL
STD NSC SINGLE GULLY

STD NSC MANHOLE

1800mm DIAMETER - REFER DETAIL

 

 

 

NOTE:

1, NOTWITHSTANDING THE
STORMWATER STRUCTURE
LEVELS SHOWN, THE
COVER OR GRATE LEVEL
SHALL SUIT THE FINISHED
SURFACE PROFILE.

2. THE PIPE CLASSES HAVE J

 

BEEN DESIGNED FOR

 

SERVICE LOADS ONLY. THE
CONTRACTOR SHALL
ASSESS ANTICIPATED
LOADS AND UPGRADE THE
PIPE CLASSES IF
NECESSARY IN
ACCORDANCE WITH AS
3725-1989. CRACKED PIPES
WILL NOT BE ACCEPTED.

3. CONTRACTOR TO CHECK
EXISTING CONNECTIONS
PRIOR TO CONSTRUCTION.

4, REFER TRENCH COMPACTION
DETAIL ON DRG. N13078-112

 

 

 

PIPE SIZEmm (Class)

 

315(3)

 

ROOFWATE!
REFER LAY!
N13078-112

SWALE

225(U)

PUT PLAN
FOR DETAILS

  

225(U)

 

DN 150 {IL 10.88 approx)

EWER TINE

 

300(3)

ROOFWATER SWALE
REFER LAYOUT PLAN
N13078-112 FOR DETAILS

225(U) 205(U)

    
 

 

 

DN 160 (IL 8.16 approx)
i Sewer Line

SEWER LINE

   

 

 

 

225(U) 225(U) 315(3) 225(U)

ISTING SURFACE /~

 

 

 

URF

a

WATER LINE &
DN 150

 

TE

 

 

225(U) _|_ 225(u) 300(U) 315(3)

 

 

L/h

 

N

HH

 

 

 

 

37513) 315(3) 37513)

 

 

NX

7

 

315(3)

 

PIPE GRADE %

0.40%

100%

3.00%

1.00%

1.00% 1.00%

100% 15% 1.00% 0.75%

0.75% 0.75% 100% 3.00%

0.40% 3.00% 9.03%

9.56%

 

PIPE SLOPE 1 in X
FULL PIPE FLOW VELOCITY (m/s

250.00
0.00

100.00

33.33
1

100.00

100.00 100.00

100.00 86.96 100.00 133.33

1.66 0.85 0.63

13333 | 133.33 100.00 33.33

0.63 121 0.91

250.00 33.33 107

0.53 0.54 0.81

10.46
0.74

 

PART FULL FLOW VELOCITY (m/s)

RL -9.0

133

DATUM RL fl,

237

151

123 146

158

DATUM RL +5.0 DATUM

RL 1.0

174

3.56

3.54

 

 

WATER LEVEL
IN STRUCTURE

6.625

17.148

13.966

12.813
12.599

16.388
15.035
B.613

12.028
8.832
8.710
16.773
16.619

16.573
15.560
13.061
12.143

9.584

9.570
1.124
15.659
10.671
9.382

10.585
9.382

 

 

HYDRAULIC
GRADE LEVEL

6.625
6.625

11148
11.079

13.966
13.637

12.813
12.745
12.599

16.388
16.327
15.035
14.951
13.613
B24

12.028
1554
8.832
8.724
8.710
6.73
16.619
16.611
16.575

16.544
16.387
15.560
15.202
13.061
12.167
12.743
12.687

9.584.
9.524,

9.517

9211
15.724
15.627
5.625
15.331
10.671
10.399
9.365

9.241

10.585
10.347
9.365
9.241

 

 

PIPE FLOW
(Cumecs)

0.000

0.026

0.051

0.076

0.020 0.038

0.057 0.076 0.094 0.029

0.029 0,055 0.078 0.100

0.059 0.060 0.090

0.082

 

 

DEPTH TO INVERT

0,992

0,294

1941

0.660
3.964

0.476
0.496
0.325

1932
0,758
1958
0,756

2356

0.758
2322
0.759
4212
1.900

0.692
0.718
0.738

0.699
0.719
0.717
1780
0.785
2.983
1297

1310
1448
1310
1372
1310
1516

1310
1516

 

 

INVERT LEVEL
OF DRAIN

6.308

6.250

16.962

16.700
3.396

12.465
12.445
12.400

16.225
16.000
14.800
14,600
3.000

12.800
11.236
10.900
TAAT
7.400
16.328
16.298
16.278

16.165
16.1465
15.961
14,898
14.500
12.302
12.080

8.539
8514
14.939
14.882
10.024
8.866

9.972
8.866

 

 

DESIGN SURFACE
LEVEL

7.300

6.544

18.903

17,360

12.941
12.725

18.157
16.158
15.356

13.558
11.659
9.300
17.020
17.016

16.864
16.678
15.285
B377

9.849

9.962
16.249
16.254
11.334
10.382

11.282
10.382

 

 

SETOUT

£5295.658
N1206.701

£5307.843
N1199.045

£5136.557

 

 

£5161.123
N1132.025

£5190.234
N1121.233
£5194.664
N1120.747

£5166.250
N1219.125
£5187.347
N1211.304
F5206.099
N1204.351

£5224.852
N1197,399
F5252.209
N1187,257
£5256.600
N1185.629
£5235.960
N1006.689
£5235.987
N1010.689

£5221.028
N1010,789
£5230.027
N1033,729
F5244.560
N1070,778
£5247.995
N1077.318

£5292.383
N1257.323

£5297.882
N1254.424
£5234.199
N1337,067
£5234.993
N1335.354
£5236.289
N1239.819
£5245.993

 

 

N1231.422
£5234.702
N1234.008
£5245.993
N1231.422

 

 

RUNNING
CHAINAGE

0.000

 

 

 

14.39

14390

 

26.200

0.000

 

26,200

 

31.047

e
5
70.

57.247

 

 

7500

0.000

22.500 20.00

22.500

>

 

 

 

Ss
00

20.00 29.176

91.676

4.683"

62500
96.359
0.000

 

 

 

 

 

=
1859

39,797 1387

90.785

1608

83.398

 

 

 

 

0.000

2

3

87
12819

0.000

12.81

0.000

 

 

 

 

 

56

0.000

 

 

 

 

 

LINE

FLE, NIBO78-134.duq_DATE: 05-08-2014 TIME: 16:28
ref's: X-NBO78-TIT USR: nathan taylor

RW3

a

Wa,

RW5

 

NOOSA COUNCIL

APPROVED PLANS
OPW14/0197 3 OCT 2014

 

 

FRET [CALCS [DRAWN] _OATE
vesue TUF [UF | tout

 

AMENDMENT DETAILS.

DESIGN CHECK

 

NT_[-NT_[ 05.08.16 [LINE RW3 AMENDED TO SUIT BIO SWALE

=>

 

 

DRAWN CHECK|

 

 

 

 

 

 

 

 

= elo[=]>

 

Oszmzozm:

 

 

"SCALE (METRES 7

AS SHOWN

MIGROFIUM No,

PROJECT No.

N13078

 

SURVEYOR: RPS
1 INNOVATION PARKWAY, BIRTINYA
Ph (07) 5436 7888 Fax (07) 5493 6630

"APPROVED.
MATHEW HILL RPEQ 11578

“er € BRENT THOMAS RPEQ 7862

FOR & ON BEHALF QF BROWN CONSULTING (QLD) PTY LTD

 

SHAUN PILCHER RPE. 14593}

CLIENT

QM PROPERTIES

 

PROJECT

LAKE DOONELLA NOOSA
STAGE C1 - C6

 

BROWN

Smart Consulting

 

(CONSULT AUSTRALIA

Brown Consulting (QLD) Pty Let at
Loa 3,1 lean Parke, Bite GLD Aun 675. Ears
Teghone 07 5470 9260 Facsimile 0754709262 Igo
Ricbero Carboes Mibourue Syciny Dapper Bane come = Lic 4084

‘DRAWING TITLE

STORMWATER DRAINAGE
LONGITUDINAL SECTIONS
SHEET 3 OF 4

 

 

‘DRAWING NUMBER

 

N13078-134

 

 

 
Log in to download the original file

OPW14_0197 Approved Plans Part 3 (N13078).pdf · 6.4 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.