Original source · versioned page text
Attachment F - Effluent disposal report
Attached to the e-mail MCU14/0039 Response to information request Traffic, Effluent& Waste reports email 3 of 3.
=ASI AUSTRALIAN SOIL INVESTIGATIONS --++ Site and Soil Evaluation -::-- Client :Martoo Consulting Location 305 Lake McDonald Drive, Cooroy, QLD (SP 108094) Report No.150105(A) Date:20/5/15 Phone: 07 5447 1304 Email: [email protected] Address: PO Box 1661, Noosa Heads, Qld. 4567 Australian Soil Investigations Pty Ltd ABN: 11147854439
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 13 pages
Page 2
ON-SITE EFFLUENT DISPOSAL REPORT: Lot 1 & 2/305 Lake McDonald Drive, Cooroy. Introduction: Australian Soil Investigations have been asked to perform a site evaluation of the above property to establish a solution for the safe treatment and disposal of effluent on site. For this we have conducted a Site and Soil Assessment for the purpose of determining the most suitable means of on-site effluent disposal. On-site testing for this assessment was performed in accordance with AS 1547-2000-"On-Site Domestic Wastewater Management and the Queensland Plumbing and Wastewater Code. The field work for this assessment was undertaken, on the 14/5/2015. The assessment has been based upon the proposed and existing plans provided by the client. Current operations on-site include a packing facility for the produce together with site management and maintenance operatives. Currently this sees a total of 25 persons employed on the site. This number is expected to increase to 70 persons as production increases. Design parameters will be based on these hydraulic demand requirements. Site description: The site is a rural property with a number of large capacity commercial greenhouse structures used for primary food production (ie. Vine Tomato growing) The allotment is located within the Noosa Shire Council. Two creeks run along the eastern and western boundaries of the site. Approximately two thirds of the site lies below the Quoo flood line. For this reason only a small area of land in the south east corner of the site adjacent the existing driveway off Lake McDonald Drive is suited for the disposal of treated effluent. The area is above the Quoo line and has a gentle slope in the order of 5%. On-Site Assessment: During our site evaluation consideration was given to the following: Y the available area for the primary siting of absorption areas (Land Application Area) and alternative sitings. ¥ the risk of prejudicing adjoining property and underground water supplies, by seepage or run off from the site. Y permeability, soil type and soil depth. Y drainage, and envisaged seasonal changes in ground water level. ¥ general climate. v slope and the effects of seepage and water run-off from surrounding higher ground. On-Site Testing: Three test holes were excavated in the positions shown in the attached site sketch. These holes were 100mm diameter x 600 mm deep for the purpose of site soil assessment in accordance with the AS 1547 AUSTRALIAN SOIL INVESTIGATIONS 2 ASI Ref: 150105(A)
Page 3
- 2000. A further 100mm diameter hole was excavated to determine the soil profile. The site was then Classified in accordance with AS 1547 — 2000 On-Site Wastewater Management for the purposes of effluent disposal. Results: Site Observations Ves No Suitable Area for siting a Land Application Area Adequate area for a Reserve area Is there Adequate Soil Depth depth above rock or the water table Is the Soil Type Satisfactory io ee ae oe Is the potential of runoff from the proposed area OK Is there a potential for groundwater seepage V Soil Borehole Results Depth Soié Description 0-400 Silty Sand SM Fine to coarse grained, dark grey Moist, massive. 400-1200 Silty Clay CH Med to heavy clay , orange brown Moist, mod. (Cat 5) 1200-2000 Sandy Clay CH Med to heavy clay, pale brown Moist, mod (Cat 5-6) 2000 Borehole Terminated Constant Head Method permeability results The following design criteria is applicable for the following disposal methods: Test Site: 3 4 5 Faee (mm) 75) 25 25 Time (mins) 107 375 300 (secs) 14 0 0 Indicative Permeability (Ksat) 0.0373 0.0107 0.0133 Soié Category 6 6 6 AUSTRALIAN SOIL INVESTIGATIONS 3 ASI Ref: 150105(A)
Page 4
Indicative Permeability __ Test Site: a a ; eo. Os eo Soil Category | 6 | 6 Structure ___ Moderate Moderate | Moderate __ Indicative Permeability <0.06 <0.06 | <0.06 DIR 15 al) id Recommendations: Based upon our Site and Soil Assessments we recommend the following method of On-Site Effluent Treatment and Disposal should be implemented. For the treatment of the Effluent we recommend; Advanced Secondary WasteWater Treatment System (AWTS) (NOTE: The system chosen must satisfy both the Queensland Plumbing and Wastewater Code and AS1547-2000 On-Site Domestic Waste Water Code and be approved for use by the Local Shire/Council governing the allotment.) The system should be fitted with a pump of adequate capacity to pump up to the nominated Effluent Disposal Area. A pump well and pump should be provided at the disposal area to receive the effluent from the system and equally dose the area. Current domestic rated AWTS systems are rated to treat upwards of 9800 Lt/week. A number of systems may be required to treat the expected effluent volumes produced. For the disposal of the treated effluent within the Land Application Area we recommend; A Pressuriged Surface Reticuéated Jrrigation Systom (NOTE: Where Surface irrigation is used in conjunction with an Aerobic Sand Filtration System the treated effluent shall be disinfected with chlorine prior to dosing of the Land Application Area.) We have considered both current and forecasted hydraulic loadings for the system. The size of the Land Application Area for 25 persons is calculated as follows; AUSTRALIAN SOIL INVESTIGATIONS ASI Ref: 150105(A)
Page 5
Minimum requirement — q 30 litres per person per day AS 1547-2000 Appendix 4.2D Water Supply Tank water Number of persons = 25 AS 1547 Table 4.33 Total Volume Q= 5250 mim/week Soil Category 6 AS 1547 Table 4.244 Indicative permeability 0.06 AS 1547 Table 4.244 DIR 15 mm/day AS 1547 Table 4.204 Disposal Area A= 350 m The size of the Land Application Area for 70 Persons is calculated as follows; Minimum requirement — q 30 litres per person per day AS 1547 ~2000 Appendix 4.2D Water Supply Tank water Number of persons = 70 AS 1547 Table 4.303 Total Volume Q= 14700 ~—s mm/week Soil Category 6 AS 1547 Table 4.2A4 Indicative permeability 0.06 AS 1547 Table 4.244 DIR 15 mim/day AS 1547 Table 4.2A4 Disposal Area A= 980m? WE RECOMMEND THAT A MINIMUM LAND APPLICATION AREA OF 350m? BE PROVIDED FOR 25 PERSONS. WE RECOMMEND THAT A MINIMUM LAND APPLICATION AREA OF 980m? BE PROVIDED FOR 70 PERSONS. A check of Water Balance requirements in accordance with the Code has been undertaken and have been found to comply The Irrigation System should be designed in accordance with AS 1547 ~ 2000 and comply with all relevant statutory requirements AUSTRALIAN SOIL INVESTIGATIONS ASI Ref: 150105(A)
Page 6
WE WOULD RECOMMEND THAT A SECOND 10 PERSON DOMESTIC AWTS SYSTEM BE INSTALLED WHEN THE ON-SITE EMPLOYEE NUMBER EXCEEDS 50. Construction Guidelines for Land Application Area: Surface Irrigation Consists of a reticulated pressurised irrigation system that uses a series of surface sprinklers to equally distribute the treated effluent across the Land Application Area. This system allows vegetation within the area to directly benefit from such watering which also assists in disposal of the effluent via evapo- transpiration. Points to consider in the construction of the area include the following: > To avoid runoff from the area it should be as level as possible. Any sloping areas should be terraced or retained and filled » rainwater shall be diverted around the perimeter of the area by use of open catch drains or bunding. Similarly a retention bund should be constructed around the low side of the area to retain any effluent overflow. > Sprinklers with a throw of not more than one meter shall be used and praduce coarse droplets (instead of a fine mist) to minimise the risk of aerosol dispersion and wind drift of effluent. The plume height shall not be more than 300 mm above the finished surface of the irrigation area. > The treated effluent must not be used for the irrigation of fruit or vegetables » Siting of surface irrigation shall be in a location away from regular pedestrian traffic and recreational areas, so there is no risk of direct spray or wind driven spray onto such areas. > The area should not be within vehicle paths or be near children’s play areas » Treated effluent quality must conform to AS 1547-2000 and the Queensland Plumbing and Wastewater Code. We have attached a site plan showing the proposed position of the Land Application Area and also some details highlighting the construction techniques required for surface irrigation. Preparation of irrigation area: When a proposed irrigation area has a low permeability, it is particularly important to ensure that the permeability of the soil in the irrigation area is improved and maintained and that there is an adequate cover of porous and fertile topsoil to act as immediate storage of effluent applied to it, and to support rapid growth of vegetation on the area to maximise evapo-transpiration. It is recommended that topsoil be imported to improve rapid growth of vegetation and improve the evapo-transpiration process. Requirements of irrigation system: Note: A Pump well with suitable pump to operate an Indexing valve will be required at the Irrigation area in order to ensure equal dosing of disposal area. This pump well is to receive the pumped effluent from the AWTS. All irrigation pipe work and fittings shall comply with all parts of AS 1477 or AS 2698.2. The distribution irrigation lines should be buried to a minimum depth of 100mm. There shall be no cross connection AUSTRALIAN SOIL INVESTIGATIONS ASI Ref: 150105(A)
Page 7
between any irrigation pipe work and the potable water supply. Any pipe work used for the transport of effluent included treated effluent must be lilac in colour Along the boundary of the surface irrigation area there shall be at least two warning signs clearly visible to inform the occupants of the premises that recycled water is used for irrigation. Each sign shall comply with AS 1319 and have: (a) lettering visible at 3m and (b) wording: Recycled Water Avoid Contact DO NOT DRINK Prior to the use of the system, the warning signs and the landscaping and surface Preparation must be completed. The Land Application Area must also be inspected and approved for use by Allgo Waste Management Siting of the Land Application Area: The current Code of Practice for On-site Sewerage Facilities provides minimum horizontal/vertical separation distances for Land Application Areas. They are as follows; Surface Land Application Areas (ADVANCED SECONDARY) Property Boundaries Upslope from the Area - 2.0m Property Boundaries Downslope from the Area - 4.0m Dwellings or buildings - 15.0m In ground swimming Pools # 6.0m In-ground potable Water Tanks - 15.0m Dams, Watercourses or Bores - 10.0m Vertical distance to water table - 0.6m A nutrient buffer zone is to be established within the land application area and downslope of the area. In no instance shall Effluent be used for irrigation of fruit or vegetables. No Vehicle loading or children’s recreational areas to be applied or constructed within the Land Application Area, System Maintenance: The owner of the property shall ensure that all manufacturers maintenance procedures are undertaken in accordance with the local authority and the manufacturers recommendations for what ever system is installed. The system must be inspected/tested on a regular basis in accordance with the manufacturers requirements and all Statutory requirements from relevant local and state government agencies. System Installation: Installation of the system must be undertaken by a qualified plumber in accordance with local authority requirements and in accordance with the relevant Australian Standards and Australian Building Code. Definitions: Design Loading Rate (DLR) The long term acceptance rate (LTAR), reduced by a factor of safety, expressed in L/m?/day or mm/day as applied to the horizontal design area of a land application system. Design Irrigation Rate (DIR) AUSTRALIAN SOIL INVESTIGATIONS ASI Ref: 150105(A)
Page 8
The loading rate that applies to the irrigation of a land application area with effluent of a secondary quality. It is expressed in L/m2/day or mm/week. If a spray irrigation system is used, the secondary effluent is subject to continuous disinfection. Durable Aggregate An aggregate with the grading requirements specified in AS 2758.1 for single-size course aggregate for nominal sizes from 20mm - 40mm. Dry Vault Commonly known as “composting toilets”, a chamber that receives and treats human and domestic organic waste using a biological degradation or dehydrating process. The only water used is for cleaning or assisting the biological degradation process. Geotextile Any permeable durable synthetic textile material used with foundations, soil, rock, earth or other geotechnical engineering related material. Land Application Area The designated area of land and reticulation system used for the disposal of the treated effluent. LTAR The long term average rate an effluent can be adsorbed into the soil of a disposal system, expressed in litres per square meter per day. LTAR is dependant on effluent quality, permeability and organic loading. Permeability The rate clean water is transmitted through a soil, expressed in meters per day. Terrace Where the trenches are in an area where the slope exceeds 15% (approximately 1 in 7) they must be terraced. Water Reduction Fixtures Fixtures include 11/5.5 litre water closets, shower flow restrictors, aerator taps and water conserving washing machines. Nutrient Buffer Zone An area planted with suitable plants required to take up any excess nutrients produced within the area. Plant selection should include native and indigenous species. This would include grasses shrubs and trees. Report Limitations: The log sections in this report should be representative of the soil conditions over this site, however, soil conditions can change dramatically over short distances. The person responsible for installing the system must observe the soil profile and ensure it matches the soil profiles recorded in this report. If soil conditions differ from those recorded by us, we must be immediately notified so that further investigation can be carried out and the system design modified if necessary. This work may involve additional fees and costs. This company will not accept any responsibility for additional costs to any party as a result of soil variations. In writing this report, we have also considered all the information supplied to us by our client. Should the client or his agent have omitted to supply us with relevant information, our report may be irrelevant and/or inappropriate. We do not take responsibility for the consequences in such cases and we will make an additional charge if as a result, more testing or rewriting of this report is necessary. AUSTRALIAN SOIL INVESTIGATIONS ASI Ref: 150105(A)
Page 9
The operation of the disposal system is dependant upon the hydraulic load, the type of the material entering the system and the maintenance of the system. As these factors are beyond the control of this company do not take any responsibility for the long term adequacy of any disposal system construct n this site or the consequences of its malfunction. Sean Richardson - RPEQ For and on behalf of: AUSTRALIAN SOIL INVESTIGATIONS. AUSTRALIAN SOIL INVESTIGATIONS 9 ASI Ref: 150105(A)
Page 10
Approved 10 EP Person Aerated Waste Water Treatment System. Supply from pump set, sized for 24L/min (min.) to disposal area. =\ Non-Return valve where AWTS below Surface runoff diversion drain or bund. Revision | Description Date 15/10/08 Surface Where the ground slope exceeds 15% the area must be terraced into 3.0m wide platforms containing a minimum of 1/25mm laterals each. Provide 2.0m seperation between platforms. aplication area. 32mmDelivery line Indexing(K—-Rain valve) No. of ports to siut size and no. of laterals.Ensure K-Raine is at highest point. Distribution pipe pipe sized to ensure equal flow to sprinklers, (25¢ min.). | Extent of land application area (hatched), size as indicated on plan. YW _————————— Legend Large drop sprinklers, 300 high maximum plume height, 4(No.) sprinklers per 100m2 of irrigation orea.(Eg.Wobblers) 3000 Min. Zl Surface runoff Se retention bund. Large drop sprinklers, refer above for spec’n. Mulch or Topsoil, 200mm deep Min. Diversion Drain. Ground Level TERN WS 1000 Ba Retension J Bund. i YYZ OULD LEGILLO SOG GS. CLAY SITES :Apply Gypsum at — LELLLE: oe LEGA 8 i¢ 1kg/sqm and rip the soil to a £ depth of 200mm. OTHER : Scarify to a depth of mecetec leds 200mm. a Upon completion the disposal area shall be planted with approved vegetation, refer attached listing. Drg No. ABS-—O01 1. The Plumber is responsible for locating all existing services within ond AUSTR ALI AN adjacent the allotment prior to commencing the work. 2. This drawing is to be read in conjunction with the attached details and the SOIL INVESTIGATIONS specifications and requirements of Australian Soil Investgations Absorption Report. 3. The installation is to be in strict accordance with AS 1547-2000, Local Authority requirements ond Australian Soil investgations Absorption Report. 4. The work is to be undertaken ond completed by a registered plumber. JABNIT 147 854 439 1/11 PROJECT AVE NOOSAVILLE QLD.4569 Ph 04280 310 453 Fax (07) 54472 634 STD DETAIL Drg No. ABS-009Rev-A
Page 11
Lot number 1 & 2
RP No. SP108094
Local Authority : NOOSA COUNCIL
County of
Area - 33.4ha
Surface
Drainage Good.
i Grasses &
Megeignon Scattered Trees
BH2 .
@ Borehole location.
J-7% Slope
measured as a percentage gradient from
high ground to low ground.
DO NOT DIMENSION OFF THIS DIAGRAM.
Existing Creek
Existing Green
Houses.
Existing 15mx30m_ packing
shed
Location of Advanced Secondary
Effluent Treatment System Refer
Org 150105-ABS.1 for details.
Proposed Land application Area.
Surface Irrigation,
Refer Drg 150105-ABS.1 for
Existing Staff Parking Area details.
Drg No. ABS-001
Revision | Description Date
Existing Driveway
General Notes :
1. Do not scale from this drawing.
2. The final position of the disposal area is to be determined on-site in
accordance with the noted minimum offsets, minimum pipe grades and
site constraints.
3. The Plumber is responsible for locating all existing services within and
adjacent the allotment prior to commencing the work.
4. This drawing is to be read in conjunction with the attached details
and the specifications and requirements of Australian Soil Investigations
Absorption Report. No.150105(A). Do not commence construction without
first referring to this report.
5. The installation is to be in strict accordance with AS 1547-2000,
Local Authority requirements and Australian Soil Investigations Absorption
Report. No.150105(A).
6. The work is to be undertaken and completed by a registered plumber.
7. Mater reduction fixtures are to be used where nominated in the
Effluent Summary below, refer report No. 150105(A) for details.
ABN11 147 854 439
AUSTRALIAN
SOIL INVESTIGATIONS
1/11 PROJECT AVE NOOSAVILLE
Ph 0428 310 453 Fax (07) 5447 1904
Scale 1:5000
Title: SITE PLAN - On-Site Effluent Disposal
Project 305 Lake McDonald Dr
Cooroy
Date: May 2015
Ne
Drg No. 150105-AB
Page 12
Revision | Description Date
Lot number 2
ES Porth of heteaa EFFLUENT SUMMARY — 25 Persons
/ Location of 10 Person Advanced Secondary County of March Application system Advanced Secondary Treatment System
/ | Treatment Plants (Units). Area - 4.956h
Up to 50 Persons ~ 1 Unit eg Se are Disposal system Surface Irrigation
| p to 70 Persons - 2 Units :
\ - \ (Ensure pump of sufficient size to pump to Area Required 350 Sq.m
isposol area. = ;
Leet epee te) Soil improvement required — |No
Water Reduction Fixtures Yes
\ | Water Supply On-site Storage Tanks
|
\ | i ion 25 People
e | | 10m MIN. Setback from all seasonal Maximum Populatio P
me 30 di and existing watercouses and dams This summary details the parameters for which this system has been designed for. Any variation to the
} ., Rising Nai to to Land Application Areas. parameters may require a redesign of the system to reduce the risk of falure.
J/ ’
\ , ee a EFFLUENT SUMMARY — 70 Persons
3 | ey \ Hn e Lond Application Area to be located
|
Lond [application Area above 0100 Flood Level Application system Advanced Secondary Treatment System
Disposal system Surface Irrigation
Nutient Buffer Zone to be planted
in and around Land Application Area. Area Required 980 Sq.m
Soil improvement required | No
Water Reduction Fixtures Yes
PROPOSED LAND APPLICATION AREA, 7
Surface krigation to be used, Water Supply On-site Storage Tanks
fina! size and location to be determined on site. Maximum Population 70 People
a ication A
25 Persons ~ 350m? _{Current) This summary details the parameters for which this system has been designed for. Any variation to the
70 Persons - 980m*(Future) parameters may require a redesign of the system to reduce the risk of failure.
Land Application Area adjusted accordingly to suit
number of persons daily usage
Surface
Drainage Good.
Provide a surface mound or bund
for diversion of stormwater runoff Vegetation Grasses &
around the perimeter of the area. Scattered Trees
\\ \\ 3
l\ \ \\ ) CS => == —— ji
\ : Expected Available Area] “Loperty boy
i! (*) cH 3/S ee
\ Provide a minimum 10.0m 3s 2 is 2.0m Min. offset from ee
A setback from water course nie Upstope or side et
to surface irragation and M OF abs. — Property Boundary to
\ reserve greg. Oreg, disposal area.
\ \ \\ x
\ \ \ Provide landscaped retension mound or /
| } \ \ bund for catchment of surface overflow
| | i 3 4 from area. Pump Well with
| | \\ \ Pump & Indexing Valve.
| | ff EGEND os ! E PLAN (k-Raine or eqully approved.) * ~~
ued ale 1:
@ 8H? Borehole location ABN11 147 854 439
, Title: SITE PLAN - On-Site Effluent Disposal
<—, Slope AUSTRALIAN c
2% measured as a percentage gradient from SOIL INVESTIGATIONS Project 305 Lake McDonald Dr
eee) 41/11 PROJECT AVE NOOSAVILLE Se
DO NOT DIMENSION OFF THIS DIAGRAM. Drg No. ABS-001 Ph 0428 310453 Fax (07) 5447 1904 | Date: May 2015 | DrgNo, 150105-ABS.1
Page 13
Plumbing Services
ca NOOSA COUNCIL pronjesaasso0
[email protected]
SITE EVALUATOR(S )
NAME: (Principal Evaluator)......Sean, Richardson
COMPANY/AGENCY.. Australi
Address.........1/11 Project Ave, Noosaville Q 4566
Phone: (......). eT NOR aches
SIGNATURE: @F-EVALUATOR? tcc. iaces.cinct ee OES Ecc eed. DATE: 27/05/2015
SITE INFORMATION
Location Details:
Locality: BOO YE I ee msad there eee thesomecdhedes
QW casual base te teenagers yeane paysagats Fee avape
Address: .....39
Phone:(......).
Site Plan Details Attached (Ref. No. or description)
Soil type and major soil consideration from soil maps etc:
Climate
Annual rainfall: 3429.00.00... mm
Data’sounce\used: s. Burcamol Met... Swanerm salty: tu: hunter sete sme yt. wtetaaie lagi heli ge uate Boe
Intended Water Supply Source:
Public Supply o Rainwater (roof collection) &
Photographs(s) or Video attached: (Please tick box) YES [] NO Wl. (Specify details):
ON-SITE EVALUATION
Work Undertaken:
Details: ...Site and Soil Assessment
Date: ...14/05/2015 | Weather: ....... ICE: A eRe eae Pee hed noe (on day and proceeding week)
Photocopy of desktop study attached (Please tick box) YES TJ NO &l (Specify details) ......0...00000 eee
Topography:
slopes OG sek Vidlor nakdetes head Nallinascbsoe Ground Cover: ....... Grassess & Scattered Trees
Geology confirm: (Piease tick box) YES 1] NO B&]
Soil landscape confirmed: (Please tick box) YES [] NO
DrainagelPattetns: .. 2.0 et. 2 see ee Site Plan details attached: YES / No: 20105-Ab e . j
Clearances 8 evcaeees. (Ae ten le. aceey aesenenas see eiaice aed Site Plan details attached: YES / NO; 190105-AB 5.1
Boundaries: .. Allowable Minimum: ...........000.......0.0000 Available:
Waterways: ..
Embankments:
Other (specify): ......
sitelmistonyAlanGlUuSe) iat fet eee) eee Seemabery, Werk) le ee Wee EA i ete eee
Environmental concerns (e.g. native plants intolerant of phosphorous load, high watertable, swamp,
WaLEIWAY WELC)! co-uc- 1. carries. fo cretoreapseus tyes ONT Gan URS RAT SMES CR PER ete et nee ete eh te ae
... Stands of trees/shrubs: ..............:...00006- Wells/bores: .
... Buildings: 15000mm
Page 14
Depth of seasonal watertable:....... cece ees eeseseeecseeereeateses
Need for cut off drains/diversions banks: ...
Needifor suntace watemecllecton/ Gut iofidlralis; 2x. -skexxccwsmvsensgraebenedanster tun cnqeranswapravenvyrernencruencesconessenuess
Treatment plant lid shall be above Q100 flood prone afea:... oo... cece eee eee een eee teeter nents setae ee
Availability of reserve/setback areas (show details on sketch plan)
Reserve area available for extensions: 2.0007... ccccceeceeeereeeee % of design area:....100%. ....... eee
Photographs attached: YES L] NO K] (specify details):.0...0..0 cocci cce cee ceteeteeeeernreeteeeenserueeaneens
SOIL INVESTIGATION
Soil Profile Determination: Mark on site plan scaled or dimensioned: ...............00000. cents
Test Pit! [1 Borehole: @theh: Wl _. Rl6aseSPECify JE... s.sesecez.:0s den eigen es LA
Reporting: (Attach Bore Logs):............ccsceccceeeceeneeere eee aee ees
Estimated Soil Category: .....0...00..0 cece cece ener te eee cnttteeereneas
SUMMARYS? tay oes eaten cnn) Rane eter te ercem lees Sone Permeability:........0.00...0. m/day DLR/ DIR
Site Test 1 2 3 4 5 6 ite
Soil
Category 6 6 6
GENERAL COMMENTS
REMaiRiMGEMAttens OMCOMCEIMANS? 6. .....c cc accece enn sievecie ses cesses ensleneee se ssgjeceans Hesse pas eglyedeessselieensne es s.ana\selchlileeeee
Type of land application system considered best suited to site and why?
ASTS & Surface Irrigation - Site & Soil Assessment
Overall evaluation of minimum land application area for the site (comprising, absorption area, space between
and surrounding the absorption area elements, setbacks and the reserve area): ..........00 000s ecee eee e ences
Other Comments eg special precautions which may be needed:
TY PEKOMSYVSCOM 5 erated cet aneis ae acted ow aginaiuntbdacnionntlnedaypeas «oe «do-« BS palaepiearenng Nama CetEM ne Ree wma ee elt Mal banenenerse eas
TYP@roOMBsposalt Ana Wer ee) ..cis... ceccnned end neh beg cece Bebb ceeeadueceseetscntercaeeersteleGhhee ite oesdieseutlcer tenet, deals
LE OF FAR WOK ce ce) a neir as cep canenscennnneenemetpaseneaianenenernnntaneeereqinscnenesmhennsesenenysene nnenharenagensiaceanesenenseneenaces
Emiiters spacings.. ... Spray spacings.. ‘i
Me HPOWAS eos. es nnt sealant ee es es ania Flush out valves..............cc cece eeeees Air relief valves.....0...... ee
Slope at Disposal Area............ cee eeee neces % Surface Irrigation fixed sprinklers only (max 20 % slope
Movable sprinklers spray area must cover minimum 50% of LAA, Surface Irrigation area to be mulched and
planted to ensure effluent is contained within designated area
ize of retention moun
Soil modifications ripped /import soil /mulched / planted (Please circle best description)
Total Load of all system on the property over 20 EP (Please tick box) YES LI NO (
Holding Tank position and size on site plan including pump out line position (Please tick box) YES 0D NO 0