Skip to the record
The gold standard in government transparency.

Council archive · source document

SUPERSEDED COMPILED Decision Notice [As Published] · 132004.5743.02

of 13

Text shows just the words. Original shows the document exactly as it was published.

NOOSA COUNCIL IDAS Development Application Decision Notice                                                 7 of 13


47.   Digital detailed design drawings and calculations shall be submitted with any application for a
      Development Permit for Operational Works in respect of roadworks and stormwater drainage works. The
      design shall be in accordance with Council’s Planning Scheme Policy PSP05 – Engineering Design
      Standards – Roads, Drainage and Earthworks. To avoid conflict with underground pipes or services, all
      existing and proposed services required by the development shall be shown on the plans.

48.   To facilitate production of As Constructed drawings it is suggested that all design drawings are submitted
      in the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the use of ADAC are
      available at www.adac.com.au).

49.   Any damage caused to any public utility during the course of construction shall be repaired to Council’s
      standards and at no cost to Council.

50.   Any alteration of any public utility or other facilities necessitated by the development of the land or
      associated construction works external to the site shall be at no cost to Council.

51.   The transportation of all materials to and from the site shall be undertaken in a manner such that no
      particle matter escapes onto a public road. All vehicles carrying materials either to or from the site shall
      be covered to prevent materials including dust being windblown from the vehicle.

52.   As Constructed drawings and data shall be certified by a qualified experienced Civil Engineer for design
      intent, and a Licensed Surveyor shall certify the cadastre and the location, level and type of all services
      and structures. All of which shall be submitted to Council for checking and for Council’s records.
      The data must fully detail levels for all engineering works including but not limited to drainage structures,
      finished ground levels and pavement surface levels. The data shall be submitted in the Asset Design and
      As Constructed (ADAC) digital format.            (Guidelines on the use of ADAC are available at
      www.adac.com.au).
      Approval of works shall not be granted until all As Constructed information has been supplied and
      accepted by Council.
Environmental Health
53.   A Waste Management Plan shall be submitted prior to demolition, removal or relocation of the existing
      building on- site.
      A Waste Management Plan is also required for construction of any building that requires development
      approval.
      Waste Management Plans are required to be submitted in accordance with Planning Scheme Policy 11,
      see table below.
      Waste storage areas are to provide for adequate separation of all reusable, recyclable and waste
      materials. These shall be located so that they are convenient and safe to use. (Waste Management Code)
      The Plan shall contain the following information:
              The site area for the storage and separation of waste is to be shown on the plan drawings
               accompanying the application.
              A waste management table as indicated below is to be completed showing how waste material is
               to be segregated - recycled – reused or disposed.


          MATERIALS ON-SITE                   DESTINATION
                                              Re-use and Recycling              Disposal
          Expected      waste    Estimate     On-site              Off-site            *specify contractor
          materials              volume       *specify re-use or *specify contractor and landfill site
                                 (m³)         recycling methods    and end user
          Excavation material
          Green waste
          Bricks
          Concrete
          Timber-please
          specify
          Plasterboard
          Metals    -   please
          specify




AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@8805e436\@[email protected]

Used in these records

About this file

File size
56 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SUPERSEDED COMPILED Decision Notice [As Published].pdf · 56 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.