Original source · versioned page text
Engineering plans
Plans and drawings: the text below has words only, no drawings.
Original PDF page 7, section 1. The text section number identifies this passage in the reader.
LEGEND
CWDC
Indicates Clean Water Diversion Channel
(Refer DC-01 in IECA Std Dwg's)
DWDC
Indicates Dirty Water Diversion Channel
(Refer DC-01 in IECA Std Dwg's)
Hatched area indicates
Indicates Stockpile area
No Go Zone.
Indicates Sediment Basin (Refer SB-01 to
SB-06 in IECA Std Dwg's)
FD
Indicates Fabric Drop Inlet (Refer FD-01 to
FD-02 in IECA Std Dwg's)
Indicates Rock Entry/Exit Pad (Refer Exit-01
to Exit-06 in IECA Std Dwg's)
CWDC CWDC CWDC
Indicates Sediment Fence (Refer SF-01 to
SF-02 in IECA Std Dwg's)
S S S
SEDIMENT BASIN NOTES
S
· Water from the Sediment Basin is to be
discharged onto the stabilised outlet structures
or into the existing easement after 7 days from
the completion of a rainfall event.
S
· A 'full of sediment' marker must be placed in the
DWDC
sediment basin to show the design capacity
depth of the settling zone volume & to indicate
when removal of the sediment is to be carried
S
out.
Existing concrete lined
stormwater swale.
S
S
S
S
DWDC
S
Inflow
Maximum water level. Internal Baffle. Spillway.
Site office.
S
Settling Zone
Total Volume = 390 m3
S
3000
1200
Sediment Storage Zone
DWDC
S
Total Volume = 196m3
DC
T
DW
SW
T
S
T
DWDC
Baffle
SW
TYPICAL SEDIMENT BASIN SECTION
T
SW
Baffl
S
T
DW SW
e
Spillway wier & DC
SW
DWDC
outlet pump.
SW
T
SW
SW
SW SW SW SW SW SW SW
FD
Existing SW Pit & line to be
disconnected & removed.
Rock lined batter to
existing SW Pit.
Issue Made By Date Description PROPOSED COMMERCIAL DEVELOPMENT Scale : 1:500 AT A1 U.N.O. NOTES:
O PC 06/07/18 Preliminary ONLY - for DA Approval
at NO. 5 TAYLOR COURT, COOROY
REVISION
Job No.: 18-0165 1. Do not scale drawings.
2. Scale is correct at A1.
CLIENT: HASS HOLDINGS PTY LTD
Dwg No.: C06 3. Check and verify all dimensions
Designed By : B.J. WINNING BEngTech (Civil) Drawn By : PC Date : 29/05/18 prior to commencement of work.
Certified By : B.R. CROMAR BEng (Civil), MIEAust, CPEng, RPEQ, NPER Date : 06/07/18 Ph: (07) 5444 5578 Email: [email protected] SEDIMENT & EROSION
See the original