Details
LOT: 2
Plan : SP 265110
Parish : -
County : -
LGA : Noosa Shire Council
Locality : Ringtail Creek
Zone : Rural
Housing Overlays :
10
Site Area : 562685.04m2
6 51
SITE NOTES
P2
These schedules are to be read in conjunction with
architectural drawings, structural engineer and
hydraulic engineer drawings and any other external
consultants. Any discrepancy with these schedules or
2S
other documentation is to be referred to the designer
for written direction prior to the commencement of
works. All works to be carried out in accordance with
the engineers design and documentation.
All works to be in accordance with the Building Act
1975, Standard Building Regulation, Building Code of
a ry
Australia, Queensland Development Code, Local
d
government regulations and relevant Australian
boun
Standards. The Builder is to clarify all dimensions on
ck to 14 150
site prior to the commencement of any works. The
river
author of the drawings takes no responsibility for
3
details as shown if changes are made during or prior to
construction without written notice or approval. Do not
a
setb
scale off plans use figure dimensions only. The
maximum height of construction is to comply with the ry
6 da
local authority planning scheme (excluding relaxations 26 oun
3 b
11 to
as per town planning approval). The author takes no k
b ac
responsibility for cut/fill levels resulting from the se t
documented levels and contours.
The Builder is to clarify all dimensions on site prior to 00 6.00
5. 7.00
the commencement of any works. The author of the
drawings takes no responsibility for details as shown if 0 top of bank 8.00
changes are made during or prior to construction 4.0
8.00
without written notice or approval. Do not scale off 8.00
0
3.0
plans use figure dimensions only. 9.00
The Builder is to comply with statutory and contractual
environmental protection requirements, including the
provision of sediment control barriers and controlled 10.0
gravel access to the site during construction, with best
0
top of bank Proposed
practice methods used. 137°17'59" Secondary
Proposed Residence
Builder to locate all services before commencement of 58.441
3.00
Dwelling 9.00
construction.
00
IN
4.
/P
House to be setout by a registered surveyor. Surveyor
C
0
M
to provide certificate at frame and completion stage for
5.0
9
TB
setba
230°09'23"
39°55'30"
confirmation of building setout and heights. 29
23.678
ck to
exist 154
19.623
164 606
setback to boundary ing v
egeta
tion li
ne
Floor Area
0
9.0
Area m2
0
6 .0
GFA Craft 62.70
GFA Main building 534.05
GFA Secondary Dwelling 62.70
659.45 m²
way
se
ve
tb
a
d ri
ck
to
ng
e
ex 51
lin
isti
ist 0
0
in 35
n
ck
ex
9.0
tio
g
setba
ve
eta
Noosa River
ge
7.00
eg
ta
tin 08
tio
boun 834
gv
xis 62 1
d a ry
n
lin
e
885
oe
00
kt
10.
t
ac
stree
8.00
tb
se
N
PI
A/
M
7
TB
Existing
Dam
APPROX. EXTENT OF
PREDOMINANT TREE
150
9.00
314
LINE SHOWN SHADED :
y
existing drivewa
FIRE SOURCE
Proposed
residence 3
26
6 APPROX. EXTENT OF
11
164 606 PREDOMINANT TREE
LINE SHOWN SHADED :
FIRE SOURCE
APPROX. EXTENT OF
PREDOMINANT TREE LINE
SHOWN SHADED :
FIRE SOURCE
34
885 8
264 948.13 m2
APPROX. EXTENT OF
PREDOMINANT TREE LINE
SHOWN SHADED :
FIRE SOURCE
35
000 Proposed shed
(inside existing
clearing)
ox
pr
ap
0
00
25
5
00
14
0
Location plan Site plan
1:5000 1:500
/Users/benthornton/Documents/Cadfiles/2203 - Hill & Heron/Archicad/
08092022/2203.pln
sbt designs pty ltd t/a
Skale Building Design project Residence lot no. 2 DA04 Development application issue 8/9/2022
project number
Mobile: 0412 025 657
for David Hill & Sonja Heron plan no. SP 265110 DA03 Development application issue 6/9/2022
2203
skale
DA02 Development application issue 27/7/2022
skale.com.au 36 Riverpark Drive drawn BT
DA01 Development application issue 8/6/2022
drawing number
[email protected]
building design A.C.N. 123 976 296 QBCC: 1143 609 at Ringtail Creek Qld scale (A1) 1:100, 1:500, 1:5000, 1:1 Rev Details Date 01 DA04 © Skale Building Design