15104 - SBSMP - Rev 0 · MCU13/0215

Attached to the e-mail OPW16/0097 - Operational Works Application.

Attached to the e-mail Operational Works Application – OPW16/0253.

of 70

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

STREET

  

 

if

 

 

6,000 SETBACK

9,200

S
x
I

ht

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELANDA

 

 

 

 

 

 

 

 

 

 

 

 

PROPOSED

APARTMENTS

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

_ 223°00'

 

 

 

 

REAL PROPERTY DESCRIPTION

LOT 399 & 400 ON RP 48112
PARISH OF WEYBA
COUNTY OF MARCH

CONSTRUCTION NOTES

GENERAL ALL WORK TO COMPLY WITH BUILDING CODE OF AUSTRALIA (B..A)
ANIENDMENT 2015 AND ENSURE THAT LOCAL COUNCIL REQUIREMENTS.
ARE MET. THIS CONSTRUCTION BEING CLASS 2 AND 7.

MAINTENANCE PROVIDE A MAINTENANCE SAFETY ACCESS SYSTEM TO SAFELY
SAFETY MAINTAIN THE EXTERNAL FACADE AND ROOF. DESIGNED AND
INSTALLED IN ACCORDANCE WITH AS 4488 PARTS 1 & 2.

SITE VERIFICATION BEFORE COMMENCING CONSTRUCTION ALL DIMENSIONS, EXISTING
LEVELS, FINISHED LEVELS AND ALL SITE SERVICES ARE TO BE

VERIFIED.
ARCHITECTURAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH
ANY ASSOCIATED CONSULTANTS DRAWINGS.

FIRE PROTECTION - FIRE RATING TO COMPLY WITH PART C1 OF THE B.C.AFOR CLASS 2,
AND 7 OF CONSTRUCTION TYPE
SEPARATION OF OPENINGS TO COMPLY WITH PART C2 OF THEBOA
PROTECTION OF OPENINGS TO COMPLY WITH PART C3 OF THI
FIRE DOORSEY REQUIRED (AS NOTED "IRON ORAWINGS) SHALL
HAVE A MINIMUM EBL 60/20 WITH MINIMUM 1 HOUR RATED SELF
‘CLOSER AND LEVER HARD!
FIRE DOORSET REQUIRED (AS NOTED "2H ON DRAWINGS?) SHALL
HAVE AMINIMUM FRL -/120/30 WITH MINIMUM 1 HOUR RATED SELF
CLOSER AND LEVER HARDWARE.

FIRE RATINGS — EXTERNAL WALL MECHANICAL SHAFT 90/90
LOADBEARING 90/60/30

INTERNAL
LOADBEARING g0i90%0 © ROOF BEAMS. 90/6080

‘STAIR WALL 90/90/80

INTERNAL FLOOR BETWEEN
NON-LOADBEARING 18060 UNITS: 90/90/80

BASEMENT WALL FLOOR BETWEEN
LOADBEARING 120/120/120 UNITSAND BASEMENT 2402407240

LIFT SHAFT 90/90/90

STRUCTURAL REFER STRUCTURAL ENGINEERS DRAWINGS FOR FOOTINGS,
TIE DOWN, BRACING & FRAMING DETAILS

3,680 SETBACK >}

6

TIMBER ‘STORAGE & ERECTION STRICTLY IN ACCORDANCE WITH AS 1720
TIMBER STRUCTURES CODE & AS 1684 - TIMBER FRAMING CODE

TERMITE CONTROL TERMITE CONTROL TO BE INSTALLED TO MANUF. SPEC. AND TO
COMPLY WITH BCAB1.3())

CONTROL JOINTS GENERALLY WHERE FLUSH FINISH IS REQUIRED BETWEEN TWO.
BUILDING ELEMENTS, PROVIDE A V-TYPECONTROL JOINT PROVIDE
CONTROL JOINTS AT MAXIMUM 3 METRE CENTRES TO EXTERNAL
FILED AREAS SUCH AS BALCONIES. DRIVEWAYS. ENTRANCES ETC.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR CONTROL JOINTS

6.705,

EXTERIOR F.C SHEETS FIXED STRICTLY IN ACCORDANCE WITH MANUFACTURERS
CLADDING WRITTEN SPECIFICATIONS,

EXTERNAL FIXINGS TO BE NON-COMBUSTIBLE AND CORROSION-RESISTANT
AND FITTINGS

INSULATION PROVIDE SISILATION BEHIND ALL EXTERNAL WALL CLADDINGS.
PROVIDE SARKING TO UNDERSIDE OF ROOF CLADDINGS.
en ee ALLINSULATION TO BE INSTALLED TO MANUFACTURERS SPEC
ROOF INSULATION PROVIDE BULK INSULATION OF R2.0 AND REFLECTIVE SARKING TO
OBTAIN MINIMUM VALUE OR 22

WALLINSULATION PROVIDE BULK INSULATION WITH R VALUE OF 1.5 REFLECTIVE
SARKING TO OBTAIN MINIMUM R VALUE OF 1.4

SOUND INSULATION AS NOTED ON PLANS.
Fw RATINGS TO COMPLY WITH PART 3.8.6 OF THEB.C.A,

‘winDows WINDOW FRAME AND GLAZING TO BE INSTALLED TO THE CORRECT
‘TERRAIN CATEGORY INCLUDING LOCAL PRESSURE FACTORS IN
ACCORDANCE WITH AS1288

5.270

SMOKE DETECTORS _ INSTALL SMOKE DETECTORS AND ALARM SYSTEM TO COUNCIL
REQUIREMENTS CONNECTED TO MAINS POWER AND INSTALLED IN
ACCORDANCE WITH AS 3 2.3 OF THE B.C.A, LOCATION
a SHOWN ON PLANS INDICATIVE ONLY. FINAL LOCATION TO BE
CONFIRMED BY SPECIALIST CONTRACTOR ON SITE

VENTILATION HABITABLE ROOMS WILL ACHIEVE DIRECT CFOSS FLOW OF AIG WITH
OPENINGS EQU ‘OF THE ROOM'S FLOOR AREA ROOMS ARE
ALSO PROvibED va Geiina Fans
ALL BATH \UNDRIES, ENSUITES NOT NATURALLY VENTILATED.
FOE MecHANIGALLY VENTILATED TO GOMPLY WITHIAS, 1968.2, AS
3666 & BCA F4.5

 

HANDRAILS HANDRAILING AND BALUSTRADING TO COMPLY WITH PARTS 02.16 AND
D2.17 OF THEB.C.A,

FIRE EXTINGUISHERS PROVIDE PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH PART
1.6 OF THE B.C.A LOCATED WHERE INDICATED ON DRAWINGS

STORMWATER, ALL ROOF & GROUND SURFACE RUNOFF TO BE CONNECTED TO

AS PER CIVILAND HYDRAULIC CONSULTANT DRAWINGS AND IN,
ACCORDANCE COUNCIL REQUIREMENTS.

10.150

PLUMBING & ACCESS ALL PLUMBING DUCTS TO HAVE ACCESS PANELS TO COUNCIL
PANELS. REQUIREMENTS, PLUMBER TO SIZE DOWNPIPES IN ACCORDANCE
‘AS. 3500 (MIN. DIA 80mm)

WATERPROOFING WATERPROOFING TO ALL WET AREAS TO COMPLY WITHAS 3740

DISABLED We WC FACILITIES FOR PERSONS WITH A DISABILITY ARE REQUIRED TO
FACILITIES COMPLY Wit AS14281 WHICH HAS SPECIFIC REQUIREMENTS FOR
“COMPARTMEEN

NT SIZE
BOOR SIDE CLEARANICES AND HARDWARE,

PAN LOCATION AND PAN SUITABLE FOR PERSONS WITHA DISABILITY

MUST COMPLY WITH AS1172,

HAND BASIN LOCATIONS AND CLEARANCES
LechrigN Ge TOILET ROLL HOLDER Lisi SWITCH , FLUSHING
a CONTROL. MIRRORS AND HAND
TIS RECOMENDED THAT-THe BUILDER BECOMES FAMILIAR WITH THE
STANDARDS PRIOR TO COMMENCEMENT OF FITOUT To We FACILITIES
FOR PERSONS WITH A DISABILITY.

 

 

 

 

‘SCALE 12100

(OY SITE PLAN

 

49.765

 

 

 

 

notes:

The designs, drawings and specication are
copyright and always remain the property of
BBackburne Jackson Design Pty Ltd

Before commencing construction:
Verity all mensions and levels.

Verity location and levels of al services on site.
Verity that floor levels and finished levels will
tenable connection to services.

Do not scale this drawing,
When in doubt refer to Architects.

amendment log

 

 

 

BUILDING APPROVAL
FOR INFORMATION: CONSULTANT ISSUE

 

 

 

 

 

 

 

 

Black burne Jackson Design
Architecture | Landscape | Interiors

 

 

 

 

nchge

87 Aerodrome Rd Maroochydore Qld
PO. Box 154 Cotton Tree Qld 4558
mail @blackburnejacksondesign com.au

 

 

 

.
is
| CEILING FANS FANS TO ALL LIVING ROOMS AND BEDROOM 1
o RI ENERGY EFFICIENCY REFER TO CONSULTANTS REPORT FOR A STAR RATED ALTERNATIVE
> hy -BCAPART ‘TO BCA PART J
a NoTE SURFACE & SUB-SOIL DRAINAGE TO BE IN ACCORDANCE WITH BCA
NOT FOR CONSTRUCTION
project: north date: 2015
PROPOSED APARTMENT DEVELOPMENT
ELANDA STREET SUNSHINE BEACH drawn: = MF
client: checked: RJ
ALDEV HOLDINGS scale: 1:100
title:
project/drawing no. sheet: At
s 7032/01 issue: 8

 

 

 

"TORETE EIaRa SST PER! Many, 14 March DOTS ZS ph

Used in these records

About this file

File size
4.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

15104 - SBSMP - Rev 0.pdf · 4.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.