Bushfire Risk Assmt & Risk Mngt Plan for a house at 64 Pheasant Lane, Doonan Revision 1 September 2020 ENAM

of 41

Page text shows just the words. Original shows the document exactly as it was published.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
                         Ecological Natural Area Management

West bushfire attack
This modelled fire burns up-slope through Eucalyptus spp open forest to attack from the west.
   • Fuel loads used are the “woodland” fuel loads of Australian Standard AS3959 of 15t/ha
      surface fuel & 25t/ha total fuel.
   • Separation of the house from the hazard: 11m
   • Slope in the vegetation = 0.40.
   • Site slope = 0.40
   • Fire run = 280m reducing the rate of spread to 0.69 of the quasi-steady state ROS
   • Flame width = 20m

7.6       Results of bushfire attack modelling
Table 9: Assessed Bushfire Attack Levels (BAL) for the modelled bushfire attacks
                                                                  Modelled bushfire attack
Modelled bushfire parameter             North bushfire attack       East bushfire attack     West bushfire attack
Separation from the hazard                      17 m                        20 m                    10 m
Vegetation                              Woodland                    Woodland                 Woodland
Modelled surface fuel load                      15 t/ha                     15 t/ha                 15 t/ha
Modelled total fuel load                        25 t/ha                     25 t/ha                 25 t/ha
Vegetation slope (degrees)                     5.3 0                      19.7 0                   0.5 0
Site slope (degrees)                           5.3 0                      15.1 0                   0.5 0
Fire run                                    >1000 m run                 >1000 m run                400 m run
Proportion of QSS ROS                         1.00                        1.00                    0.73
QSS ROS                                       1.04 km/h                   1.04 km/h               0.75 km/h
Modelled rate of spread                       1.04 km/h                   1.04 km/h               0.55 km/h
Flame width                                    100 m                       100 m                   100 m
Radiant heat                                 17.76 kW/m2                 14.85 kW/m2             18.45 kW/m2
Modelled fire line intensity                13406 kW/m                  13406 kW/m                7104 kW/m
Modelled flame length                         9.75 m                      9.75 m                  6.58 m
Level of construction (BAL)                BAL 19                      BAL 19                  BAL 19

The worst case scenario from Table 9 above is BAL 19
See Appendix 2 for a detailed software reports from which the above table was generated.

7.7       Bushfire Attack Levels for each building elevation
Australian Standard AS3959 specifies that the Bushfire Attack Level for the building elevation
opposite the bushfire attack direction can be reduced one level due to radiant heat shielding by the
house but as more than one bushfire attack id assessed as BAL 19, no shielding is available so the
Bushfire Attack Levels for each of the building elevations is:
      •    BAL 19 for all building elevations

7.8       Assessment of vegetation clearing
      •    The only clearing of vegetation is within the approved building envelope which achieves the
           bushfire risk mitigation recommendations in this bushfire management plan.




Bushfire Risk Assessment and Management Plan for a house at 64 Pheasant Lane, Doonan                  September 2020

                                                            23
Log in to download the original file

Bushfire Risk Assmt & Risk Mngt Plan for a house at 64 Pheasant Lane, Doonan Revision 1 September 2020 ENAM.pdf · 4.9 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.