Council archive · source document
Proposal Plans · OPW26/0034
Plans and drawings: the text below has words only, no drawings.
Very large file (11.4 MB): may take a few minutes to open.
Original PDF page 2, section 1. The text section number identifies this passage in the reader.
¿ play your part - print on recycled paper
Details
LOT: 2
Plan : 214048
Parish : --
County : --
LGA : --
Locality : --
Zone : ####
Housing Overlays :
Site Area : 368300m2
SITE NOTES
These schedules are to be read in conjunction with
architectural drawings, structural engineer and
hydraulic engineer drawings and any other external
consultants. Any discrepancy with these schedules or
other documentation is to be referred to the designer
for written direction prior to the commencement of
works. All works to be carried out in accordance with
the engineers design and documentation.
All works to be in accordance with the Building Act
1975, Standard Building Regulation, Building Code of
Australia, Queensland Development Code, Local
government regulations and relevant Australian
Standards. The Builder is to clarify all dimensions on
site prior to the commencement of any works. The
author of the drawings takes no responsibility for
details as shown if changes are made during or prior to
construction without written notice or approval. Do not
scale off plans use figure dimensions only. The
maximum height of construction is to comply with the
local authority planning scheme (excluding relaxations
as per town planning approval). The author takes no
responsibility for cut/fill levels resulting from the
documented levels and contours.
The Builder is to clarify all dimensions on site prior to
the commencement of any works. The author of the
drawings takes no responsibility for details as shown if
changes are made during or prior to construction
without written notice or approval. Do not scale off
plans use figure dimensions only.
The Builder is to comply with statutory and contractual
environmental protection requirements, including the
provision of sediment control barriers and controlled
gravel access to the site during construction, with best
practice methods used.
Builder to locate all services before commencement of
construction.
House to be setout by a registered surveyor. Surveyor
to provide certificate at frame and completion stage for
confirmation of building setout and heights.
31
.150m,
Current Gate 90° 2' 4
.22"
106.43
7 m, 1 6
14
Riparian buffer area
3.7
18
0° 2' 54
m,
13
9°
.60"
51
'3
9.4
9"
18" 2"
54. '3 4.5
6' 7° 3
5 7° 5 ,5
m, 77m
163
Proposed stables
7
47. 85.
58' 0.00"
Proposed residence
m, 1 7 7 °
131.277
D73
D74
Proposed studio - gym
14
.52
8m
,1
35
40
.84
4.4
8m
°5
,1
21
09
9' 0
Existing studio
.57"
°5
m,
8'
.00
9.7
13
° 40' 24
2"
"
5°
53
'2
1.6
m, 1 7 9
306.43
9"
3 m, 8 9
° 57' 25
.55"
81.616
Existing residence to
be demolished
Location plan
1:2000
/Users/benthornton/Documents/Cadfiles/2403 - Blake/Archicad/
01022026/2403.pln
sbt designs pty ltd t/a
Skale Building Design project Residence lot no. 2 DA01 Development application issue 1/2/2026
project number
Mobile: 0412 025 657
for Cameron & Jane Blake plan no. 214048 CD15 Conceptual design 11/12/2025
2403
skale
CD14 Conceptual design 10/12/2025
skale.com.au 111 Lukes Road drawn BT
CD13 Conceptual design 1/12/2025
drawing number
[email protected]
building design A.C.N. 123 976 296 QBCC: 1143 609 at Cooroy Mountain scale (A1) 1:2000, 1:100 Rev Details Date 02 DA01 © Skale Building Design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Proposal Plans.pdfRelated documentApplication case desk ↗
Proposal Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 11.4 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.