Council archive · source document
PART Response to Information Request · OPW11/0335
Very large file (26.7 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Table B-9: Full Development MUSIC Model Input Parameters - Treatment Units
Treatment devices and parameters BloretenUon Bloretentlon Bloretentlon Bloretention
Full Development CIA CIB 81 Al
Low flow by-pass (m3/sec) 0 0 0 1
High flow by-pass m3/sec 100 100 100 100
Extended detention depth (m) 0.2 0.2 0.2 0.2
Seepage loss (mm/hr) 0 0 0 0
Filter area mz 63 74 81 95
Filter de pth ( m ) 0.5 0.5 0.5 0.5
Filter median particle diameter (mm) 0.45 0.45 0.45 0.45
Saturated hydraulic conductivity (mm/hr) 150 150 150 150
Depth below underdrain pipe (% of filter depth) 0 0 0 0
Overflow weir width (m) 2 3 3 3
FULL DEVELOPMENT MUSIC MODEL OUTPUTS
Table B-10: Full Development MUSIC Model - Treatment Train Effectiveness
Treatment Train Effectiveness Source Residual Load % Reduction
Flow ML/ r 19 13 30
Total Suspended Solids k / r 3790 451 88
Total Phosphorus k / r 8.5 1.8 79
Total Nitrogen k / r 46 20.3 56
Gross Pollutants k / r 387 0 100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
PART Response to Information RequestRelated documentApplication case desk ↗