Minor Change Report 51992 213 03 (As Published)
Noosaville Local Plan Code
Built Form
The roof design is pitched at 2.5 degrees rather than the required 5 degrees required by Acceptable
Outcome AO8.5 of the Noosaville Local Plan Code:
AO8.5 Buildings and structures:
a) incorporate articulated roof forms which are visible from the street and have a pitch of no
less than 5 degrees;
b) incorporate a mix of lightweight and textured external building materials or materials that
reflect the natural environment such as timber and rock face;
c) provide variation through articulation, texture and detailing;
d) incorporate verandahs, open balconies or shaded patios for outdoor living, with open,
transparent or semi-open balustrades;
e) use understated colour schemes and low-reflective roofing and cladding materials.
f) include awnings where appropriate and should define the public realm at ground level to
provide activation and strong landscape design to the building facade.
The corresponding Performance Outcome PO8 states:
PO8 Buildings, structures and landscaping are integrated with the natural landscape and reflect
the riverside character and setting of the local plan area in terms of form, composition and
protection of neighbourhood amenity.
Assessment
The building is integrated within the existing development and is replacing a building that is
undergoing demolition to site the new amenities block. The building incorporates muted colours
and natural wooden textures alongside lightweight and modern looking materials around the
external façade. The building is set alongside an existing building on the lot that is sited away from
the entrance to the site and is not visible from any property boundary.
Flood Hazard Overlay Code
AO1 The finished flood level is not less than the minimum design levels specified in Table 8.2.6.4.
Assessment
The applicant has provided a flood certificate which indicates the DFL of 2.4m AHD for site.
The proposed amenities block is located within Council’s Flood Hazard Overlay and is required to
demonstrate compliance with the Flood Hazard Overlay Code. The finished floor levels of the
Amenities Block are shown at 2.7 AHD which complies with the applicable minimum floor levels
relevant to a habitable room / area.
Development Engineering suggests that the flood immunity requirements can be included on the
approval as an additional condition.
Existing Condition 20
Approved Plans
20 Development undertaken in accordance with this approval must generally comply with the
approved plans of development. The approved plans are listed in the following table unless
otherwise amended by these conditions.
Plan No. Rev. Plan/Document Name Date
Page 8 of 13