   APPROVED PLAN
OPW16/0014 4 MAR 2016


[OCR of page images]
 

 

 

( LIVE LOADS +)

 

THIS FLOOR HAS BEEN DESIGNED
FOR THE FOLLOWING LOADINGS:

BOARDWALK: 2.00kPa, 1.80kN

 

 

 

 

 

 

 

\ J
( FLOORING +)
BOARDWALK: —
89mm x 19mm HWD
&
40x25mm HWD PAIRS
\ J

iG
oe
—_
“
Ee
LE
=
( DURABILITY NOTES )

   

 

WHERE THE TIMBER MEMBERS ARE ABOVE 150mm OF
THE FINISHED GROUND, SELECTED HARDWOOD 10 BE
ABOVE-GROUND DURABILITY CLASS 1 WITH ALL
SAPWOOD REMOVED (OR SAPWOOD TREATED TO H3).
DECKING BOARDS SHOULD BE ABOVE GROUND
DURABILITY CLASS 1 (SAPWOOD TREATED TO H3), OR
H3 PRESERVATIVE TREATED SOFTWOOD.

WHERE THE TIMBER MEMBERS ARE WITHIN 150mm OF
THE FINISHED GROUND, SELECTED HARDWOOD 10 BE
IN-GROUND DURABILITY CLASS 1 WITH ALL SAPWOOD
REMOVED (OR SAPWOOD TREATED TO H5). DECKING
BOARDS SHOULD BE ABOVE GROUND DURABILITY
CLASS 1 (SAPWOOD TREATED TO H3), OR H3
PRESERVATIVE TREATED SOFTWOOD.

ALL FIXINGS (SCREWS, NAILS, BOLTS, ETC) ARE 10 BE
STAINLESS OR MONEL STEEL.

ALL ENGINEERED TIMBER PRODUCTS USED IN EXTERNAL
ENVIRONMENTS ARE TO BE TREATED AND INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S

 

NOTE:-
~ QAKL JOISTS ARE DJ1's U.N.O.

\

 

 

. PROVIDE JOIST TRIMMERS WITH
~\ THE SAME: SIZE/GRADE AS \IOISTS
\ ‘ \

 

PATHWAY FRAMING SCHEDULE

 

 

SPECIFICATIONS.
\

/

(Scale 1:100)

LOT 3
| GTP\1450

\

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

( DECK BEARER DETAILS NG General Notes )
AXING 1. DO NOT SCALE DRAWINGS.
MARK MEMBER GRADE | bETAIL 2. IF ANY DIMENSIONS ARE SHOWN ON THIS DRAWING,
THEY ARE TO BE CONFIRMED WITH THE BUILDER
PRIOR TO PROJECT COMMENCEMENT.
3. ALL FLOOR FRAMING WORK, JOINTS HOLD-DOWN,
_| - CONNECTIONS AND OTHER STRUCTURAL DETAILS NOT
oe! 150x75 FI4-HWD SPECIFICALLY NOTED ON THESE DRAWINGS, ARE TO
BE IN ACCORDANCE WITH ASI684~2010, "RESIDENTIAL
L _J || Twoer FRAMED CONSTRUCTION’, SECTION 4.
4, NOMINAL FIXING FOR TIMBER MEMBERS TO BE IN
f DECK JOIST DETAILS ON) J] ACCORDANCE WITH ASt684—2010.
5. ALL TMBER USED IN EXTERNAL CONDITIONS TO BE
IN ACCORDANCE WITH APPENDIX B, ASI684.2.
MARK MEMBER GRADE | SPACING | | N ACOORDANCE TH APPENDI: B, AS16642
6. TIMBER SHALL BE HANDLED AND STORED IN SUCH
A MANNER AS TO ALLOW FOR THEIR SATISFACTORY
but 15050 MAX. PERFORMANCE WHEN FABRICATED INTO THE BUILDING.
x 450 CRS | | SEE APPENDIX H, ASI684.2—2010 FOR FURTHER
F14—-HWD DETALS
bu2 150x50 3s
N SS
( TIMBER POST DETAILS >
MARK MEMBER GRADE
tpl 9100mm Fi4 - HWD
ae J

 

 

 

 

 

 

 

 

B OPW RESPONSE 17.02.2016
ISSUE REVISION /ISSUE DATE J
—_———

CONSULTING
INCORPORATING
Geo Structural & Geo Investigations
Ph: 5351 1011 or 5351 1555
Fax: 5351 1044
19/25 Quanda Road, Coolum Beach QLD 4573
Email: [email protected]
Ne
CLIENT:
Lizie Clifton & Rowan Findlay
PROJECT:
Proposed Pathway to Residence
at Lot 3

 

 

 

 

 

 

 

 

Mitti Street
Noosa Heads QLD 4567
vate Drawn by Designed by
Feb. 2016 C.H. CH.
NOOSA COUNCIL ons) | Coe ns
APPROVED PLAN 9-02 $8500
OPW16/0014 4 MAR 2016 BOARDWALK |B
—,

 

 

 

 

 

 

 

 

Used in these records

About this file

File size
1.2 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

opw16_0014 - Approved Plan.PDF · 1.2 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.