LEGEND
EXISTING RETAINING WALL NEIGHBOURING
HOUSE
EDGE OF EXISTING GARDEN Proposed Driveway contoured
Existing Blockwork Retaining Wall around existing verge trees
Existing Retaining Wall
A B C D E Reference Image 01
PROPOSED DRIVEWAY 28.164 85°33'30"
3,500 4,500 6,000 4,500
SIDE BOUNDARY
+23.98
setback
22.0 23.0
2,000.
THE NEW DRIVEWAY HAS BEEN SITED 2M NORTH OF THE
EXISTING DRIVEWAY TOWARDS THE EDGE OF THE SITE, WITH +23.63
THE ACCESS TO THE ROAD MAINTAINING EXISTING STREET 1
1,450
EDGE LEVELS 23.0
existing trees existing tree
NEW DRIVEWAY PROVIDES: 2
EXISTING HOUSE OVERLAY
• GREATER DISTANCE FROM HEAVILY VEGETATED
CORNER INTERSECTION
4,500
Existing Timber
Retaining Wall
2,000
• RETENTION OF EXISTING VERGE TREES
• RETENTION OF EXISTING FOOTPATH LEVELS
3
C
4 4,500
21.0
Outline of Existing Driveway
339°
5
6 06'
SID
ack
setb
EB
0.
2,00
OUN
4,500
22.0
0. PROPOSED HOUSE
1,50
DAR
T E RRACE
Y
7 norfolk
600. island pine existing trees
8 4,000 SETBACK
21.0
20.0
6,000. SETBACK
88 RP 81810
21.0 01 VIEW FROM HOUSE OF EXISTING VERGE RETAINING WALL
SE AV I E W
existing tree
20.0
19.0
20.0
18.0 existing tree
EXISTING LANDSCAPE
19.0
17.0
existing tree
2,000mm
18.0
02 VIEW FROM STREET OF EXISTING DRVIEWAY ENTRY
SE AV I E W T E R R AC E
PROPOSED DRIVEWAY & EXISTING HOUSE OVERLAY
SCALE 1:200
ISSUE DD03 BA APPLICATION 19-02-2019 CLIENT Deborah & Alan Kerr DRAWN MW
COPYRIGHT - These drawings to be SD01 DESIGN CONCEPT DRAWINGS 05-10-2018
PROJECT 49 Seaview Terrace, Sunshine Beach Q ROBINSON ARCHITECTS DATE 19/02/2019
used only with Architects written consent.
DD01 DESIGN DEVELOPMENT 19-10-2018 67 MEMORIAL DRIVE,
DO NOT SCALE OFF DRAWINGS. EUMUNDI QLD 4562 SCALE 1:200 (A3 Paper)
Refer any discrepancies to Architect and DD02 DESIGN DEVELOPMENT 01-11-2018
DRAWING DD007 - Site Plan - Proposed Driveway ROBINSON Ph. (07) 5442 8566
NO. DD03
verify all dimensions on site. DD02 DESIGN APPROVAL 07-12-2018 A RC H I T E CT S www.robinsonarchitects.com.au
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
190219 Seaview DD03.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.