Original source · versioned page text
Attachment 1B - UNITS 1-3
Attached to the e-mail Development Application MCU - 226 David Low Way Peregian Beach units 1-3 (Email 4).
GENERAL NOTES PEREGIAN BEACH VILLAS UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS. DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND SCHEDULES OF FINISHES. DIMENSIONS TAKE PRECEDENCE OVER SCALE. DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES DIRECTLY TO THE SUPERINTENDENT. REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS, SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS. REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS. PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE 4,905 250 4,870 250 4,905 WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA. 90 1,725 90 3,000 250 3,000 90 1,780 250 2,985 90 1,740 90 STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE WITH THE B.C.A. ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND 590 600 600 600 600 600 AS2208 AND THE DESIGN CONDITIONS AS NOMINATED. BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING 1,510 AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT 1,500 1,500 Patio Patio Patio 1,590 1.5 x 4.9 1.5 x 4.9 1.5 x 4.9 THE ENTRY OF MOISTURE INTO THE BUILDING. WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION 3.8.1 OF THE B.C.A AND AS 3740 90 90 90 ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN STANDARDS. 2,480 2,480 Ens Bed Bed Ens Bed Ens 2.5 x 1.5 3.4 x 3.2 3.4 x 3.2 2.5 x 1.5 3.4 x 3.2 2.5 x 1.5 REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS 3,940 3,940 WC WC WC SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH AS3788 & PART 3.72 OF THE BCA CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING 90 90 Bi-fold doors by 16 W UNIT 1 UNIT 2 W 16 UNIT 3 W 16 cabinet maker 15 15 15 MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm 14 T 14 14 AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL Laundry underneath T T 13 ROBE ROBE 13 ROBE 13 REQUIREMENTS staicase 12 12 12 11,710 11,710 90 90 11 11 11 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET 10 10 10 AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS 4,400 9 9 9 8 8 8 FOR MEMBER SIZES Bistro stryle blinds to external staircase 7 6 7 6 7 6 LEGEND 5 5 5 A/C AIR CONDITIONING AS SPEC. - INSTALLED 6,950 Staircase open to 4 4 4 BY CONTRACTOR AP 450 X450 REMOVABLE ACCESS external units 3 3 3 PANEL - LOCATION TO BE CONFIRMED ON SITE 2 2 2 Single Garage Single Garage Single Garage BL CONC. BLOCK WALL TO STRUCTURAL ENG. 1 1 1 6.0 x 3.0 6.0 x 3.0 6.0 x 3.0 6,000 6,000 DETAIL - RENDER AND PAINT AS SPEC. CF COLORBOND FLASHING TO DETAIL CJ CLADDING CONTROL JOINT - REFER ELEVATIONS CONC CONCRETE SLAB TO ENG. DETAIL 2,550 CPD CUPBOARD DP 90mm DIA DOWNPIPE AS SPEC. REFER TO DETAILS FOR TYPICAL FIXING DRY CLOTHES DRYER DW DISHWASHER EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH 90 90 GUTTER BRACKETS @ MAX 900 CRS EGL EXISTING GROUNDLINE 700 700 F REFRIGERATOR FW FLOOR WASTE 90 90 780 780 GD S.S GRATED DRAIN AS SPEC. 90 90 HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION HP HOT PLATES AS SPEC. 500 780 780 500 Enclosed stairwell HWU HOT WATER MR MECHANICAL RISER MW MICROWAVE 1,815 90 3,000 250 3,000 90 1,780 250 2,985 90 1,740 90 NGL NATURAL GROUND LINE OV OVEN P PANTRY 4,905 250 4,870 250 4,905 PGL PROPOSED GROUNDLINE PTF POLISHED TIMBER FLOOR AS SPEC. RHS RHS TO STRUCTURAL. ENG. DETAIL RV "WIRILY BIRD" OR SIM. APPROVED S SINK SD HARDWIRED SMOKE DETECTOR TO COMPLY WITH A.S. 3786-1993 SHR SHOWER TO DETAIL SHS SHS TO STRUCTURAL. ENG. DETAIL SL SKYLIGHT AS SPEC. T TUB T-1 INTERNAL TILE AS SPEC. T-2 EXTERNAL TILE AS SPEC. TD HWD TIMBER DECKING AS SPEC. TOW TOP OF WALL VAC IN-BUILT VACUUM SYSTEM AS SPEC. VB VANITY BASIN WC TOILET SUITE WF COLORBOND WALL FLASHING WM WASHING MACHINE Amendments Wind Rating Checked By: Status: PR Date: 20-01-14 PEREGIAN BEACH VILLAS A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT Client Signiture Approval: C 11.12.13 Site Plan revised + amendments CT Client Initials: TBC ALEX CHARLWOOD Drawing Title: D 16.01.14 Amend GFA CT Date: UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 20.01.14 Client request amendments CT PH: 0410 650 745 GROUND FLOOR BSB No.: 1043429 NOTES: ABN: 59 980 573 352 Client: Drawing No.: PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.2 E ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.