Council archive · source document
Acid Sulfate Management Plan · MCU16/0103
Plans and drawings: the text below has words only, no drawings.
> Cardno Shaping the Future CHROMIUM SUITE TEST REPORT Cardno Construction Sciences Pty Ltd ABN: 74 128 806 735 Address: 32 Hi-Tech Drive Kunda Park Qid 4556 Telephone: (07) 5452 0100 Email: [email protected] Facsimile: (07) 5452 0133 Website: www.cardno.com.au Client: Future Plus Environmental Report Number: 3740/S/67762CRS Client Address: PO Box 1250, Buddina Qld 4575 Project No: 3740/P/1155 Project: Noosaville ASS Lot Number: - Sub Project: - Internal Test Request: 3740/T/14043 Location: Supplied Sample Client Reference: 4956 Component: - Purchase Order No: - Area Description: = - Date Sampled: 11/10/2016 Sampled by: Client Date Tested: 14/10/2016 Sampling Method: Tested as Received Report Date: 14/10/2016 Test Procedures: AS 4969.0, .1, .2, .4, .7, 8, 14, .13, 14 Laboratory Number Sample Location PHxci TAA TAA Skei Scr Swas ANCg; ANC; Net Acidity | Net Acidity | Recommended Liming Rate units; - (molt) (%s) (%s)* (8) (%S8) (%Caco,)* (ms)* (H*motlt) (%8) (kg of lime per cubic metre) Lor| 0.1 1 0.001 0.007 0.02 0.001 0.01 0.01 1 0.001 oa 3740/S/67762 4956-161011-BH1-1.25 6.8 0 0.000 0.011 | 0.404 nr. 0.37 0.12 203 0.325 28.7 3740/S/67767 4956-161011-BH2-0.50 6.6 0 0.000 <0.007 | 0.180 nr. 0.12 0.04 96 0.154 13.6 3740/S/67773 4956-161011-BH2-2.00 7.4 0 0.000 <0.007_| 0.178 nr. 0.56 0.18 36 0.058 5.1 Blank 6.2 18 0.003 Notes: The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. nr: not required, pH trigger not met. LOR: Limit of Reporting if PHxc; <6.5 it must be assumed that effective ANC is zero. Effective ANC is ANC,;/Fineness Factor of 1.5. * Sc) determined as sulfate by turbidimetric method. Where liming is specified, lime should be fine grained agricultural lime of at least 90% purity. Any liming rate provided is a recommended rate only, and is based on the total of TAA Equivalent % Oxidisable Sulphur plus Potential Acidity (S,,) plus Retained Acidity (Sys) minus effective ANC; with a factor of safety of 1.5. Any recommended liming rate is based on the 0.03%S action criteria. A placed dry density of 1.7 tonnes/cubic metre has been used in calculating liming rate/s. The recommended liming rate is derived from a mathematical equation and will need to be field validated. Cardno accepts no responsibility for any loss associated with use of the calculated liming rate/s. The test results contained within this report relate only to the samples as they were received. aN ATA Ww op, | APPROVED SIGNATORY: Paul Mayes Form Number: REP CRS 27/07/201! 6 Revision 9 Accredited for compliance with ISO/IEC 17025 Accreditation No. 1986 Corporate Site Number: 3740
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Acid Sulfate Management PlanRelated documentApplication case desk ↗
About this file
- File size
- 3.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.