Log in to see the plans as drawnLIGHTING LEGEND
S/STEEL EXHAUST HOOD OVER
Symbol Description Quantity Watts COOKING LINE. HOOD CONNECT TO
LESSORS EXTRACTION SYSTEM
TBC.CONTRACTOR CONFIRM SIZE TO
IP RATED CAN LIGHT SUIT EQUIPMENT BELOW
L1 GREEN TRIM FINISH WITH FROSTED
COVER 14 -
LAMP: WARM WHITE 3000K 2100 AFFL
SUPPLIER: TBC
ROLLED STEEL 'COW SIGN'
IP RATED CAN LIGHT TO BE CONCEAL FIXED TO STRIPED PAINT FINISH TO
L1 WHITE TRIM FINISH WITH FROSTED COVER STONE CLAD WALL BULKHEAD ABOVE
LAMP: WARM WHITE 3000K 3 - KITCHEN PASS THRU
SUPPLIER: TBC
NEON SIGNAGE TO 2100 AFFL
RIBBON BULKHEAD
WALL MOUNTED LIGHT - UP & DOWN
L3 BLACK TRIM FINISH WITH FROSTED COVER
LAMP: WARM WHITE 3000K 4 -
LIGHTS TO BE DIMMABLE, WARM WHITE,
ON SEPERATE CIRCUIT
SUPPLIER: TBC
IP44 RATED LED RECESSED DOWNLIGHT
PRO
L5 REF: 22W LED, WHITE FINISH
LIGHTS ARE TO BE WARM WHITE, ON 6 -
PER
SEPERATE CIRCUIT
SUPPLIER: TBC
TY B
OUN
L6 SURFACE MOUNTED (WITHIN EXHAUST LOWEST POINT OF EXISTING ROOF
3 84w
PREP FRIDGE
HOOD) T5 FLUORESCENT (28W)
DAR
(2040mm AFFL). CONTRACTOR TO
1286W
SPEC & QUANTITY TBC BY HOOD
CONFIRM ON SITE PRIOR TO MENS STAFF
Y
SUPPLIER: TBC CONSTRUCTION - SHOWN FOR 610x60
0 TOILET
REFERENCE ONLY
460x13
GAST.
TRAY
L7 FREEZER/ COOLROOM LIGHT
OL)
50
ON SEPERATE CIRCUIT 7 - LCOH
U/B (A FRIDGE
2 DR
00
FRIDGE
DRINKS
310x12
MEAT
TOAS
UB
COOL
L8
460x10
IN FLOOR UPLIGHT
TE
IDGE
DRINKS FR
3W LED 24 DEGREE BEAM, WARM WHITE
R
3 DR
460x13
15 -
SECURITY CAGE
FREE M
SUPPLIER: TBC SC 2000 AFFL
POS
ROOM
50
ORDER
450x1050
ROO
POINT /
50
LOW LEVEL - LINEAR LED STRIP BAR COOLROOM & FREEZER
ZER
POS
460x90
ER ROOM CEILING. LIGHTING BY
TEMP: 2700K. 10w PER METER W/ ALU LOCK
EXTRUSION W/ OPAL DIFFUSER 4.2m - COOLROOM CONTRACTOR
COLD
ER
SECURITY CAGE
DECORATIVE TO HAVE DIFFUSER WHERE
DRES
0
LOCK
3600
POS
NOTED, NO SPOTTING, ENSURE EVEN
600mm
460x13
STOR W
450x1050
POS
S FRID UNDER
U/B BIN
DISTRIBUTION
1850
ER
INFILL
LINEAR LED LIGHTING TO 310x12
00 LOCK
AGE
READ IN CONJUCTION WITH DETAIL
50
GE W
DRAWINGS FOR ALL LOCATIONS ORDER POINT/BAR FRONT S/P CLEA
NING
DRIVER FOR LED TO BE LOCATED CLOSE 50 EQUI
P.
/
310x13
EXHA
TO LED, LIGHTS TO BE DIMMABLE, ON
SECURITY CAGE
SEPERATE CIRCUIT SC 2400 AFFL
450x1050
UST
SUPPLIER: TBC
1050
310x12
S/P PAINT FINISH TO NEW
HOOD
IT GYPROCK CEILING TO
TOTAL WATTS EX
00
BOH AREA
WATTS PER M2
UB AD
DRAW W
2445 AFFL
240L
ACCE R
EXIT
1100
LADD
QTY
310x10
ANDE
ERS
SS
E
POWERCOAT FINISH TO
50
EXIT
I BEAM BORDER
SC SURFACED MOUNTED SECURITY CAMERA IN BLACK
FINISH . (CONTRACTOR TO SUPPLY AND INSTALL) , 3
HWB
SPEC TO BE APPROVED BY CLIENT PRIOR TO
PREP
INSTALLATION
1286W
FRIDGE
SURFACE MOUNTED CEILING SPEAKER ,
BLACK FINISH, CLIENT SUPPLY, CONTRACTOR TO 5
1000
CONDENSER
INSTALL , CONFIRM SPEC WITH CLIENT HOOD
U
MEN
2100 AFFL
DW
1000
SAFE
EXIT S/STEEL CONDENSER HOOD OVER
EMERGENCY LIGHTING DISHWASHER (1000X1000MM-TBC).
CONNECTED TO LESSORS EXTRACT
S/P ELECTRICAL CONTRACTOR TO ADVISE FINAL 3 IN FLOOR UPLIGHT TO SYSTEM (TBC). CONTRACTOR TO
LOCATIONS & CO-ORDINATE FINAL LAYOUT,
INSTALL AS PER RELEVANT BCA STANDARDS SHINE UP ONTO BESSER CONFIRM SIZE TO SUIT DISHWASHER
BLOCK BALUSTRADE BELOW
GAS BOTTLES
SLIMLINE EDGE-LIT CLEAR PERSPEX EXIT SIGN
EXIT ELECTRICAL CONTRACTOR TO ADVISE FINAL 6
EXIT
LOCATIONS & CO-ORDINATE FINAL LAYOUT, NEON SIGNAGE TO WALL
INSTALL AS PER RELEVANT BCA STANDARDS 2635 AFFL
SPECIAL PAINT FINISH TO 2470 AFFL
GENERAL NOTES: NEW GYPROCK CEILING
PAINT FINISH TO T&G
ALL LIGHTS TO BE ON DIMMABLE CIRCUITS PANELLING TO FOH
AREA
1. FIRE SPRINKLERS TO BE INSTALLED TO SATISFY RETRACTABLE FABRIC AWNING FIXED TO
FACADE - LOGO TO FRONT FACE. SC
AS2118 (CHECK WITH LANDLORD/CERTIFIER)
2. EWIS SPEAKERS TO BE INSTALLED TO SATISFY AWNING TO ASSIST WITH AFTERNOON
AS2118 (CHECK WITH LANDLORD/CERTIFIER) SUN SHADE TO RESTAURANT DINING
3. SHOPFITTER IS REQUIRED TO CHECK ALL LEAD AREA. PROPOSED AWNING TO ALIGN
TIMES AND AVAILABILITY OF LIGHTS IMMEDIATELY TO WITH EX. LAGUNA JACKS AWNING
AVOID ANY DELAYS. LEAD TIMES MAY BE MORE THAN 12
WEEKS. SHOPFITTER IS TO TAKE LEAD TIMES INTO
ACCOUNT AND ORDER ON TIME.
4. CONTRACTOR TO SUPPLY AND INSTALL EXIT
SIGNAGE
NEW ACCESS LADDER TO POTTED HANGING PLANTS 3 x WALL MOUNTED
EXISTING CEILING STORAGE - CENTRAL TO TABLES LIGHTBOX SIGNAGE -
AREA ABOVE BOH/KITCHEN. BELOW. HIGH QUALITY CENTRAL TO TABLES
CONTRACTOR TO CONFIRM ARTIFICIAL PLANTS TO BE
SPEC & LOCATION PRIOR TO USE
CONSTRUCTION
RCP 1.0
SCALE 1:100 -
client notes D 31.05.17 PL FOR CLIENT APPROVAL drawing drawing no.
GRILL'D • All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements.
C 24.05.17 PL FOR CLIENT APPROVAL PROPOSED GROUND DA0102
• Do not scale this drawing. All dimensions to be verified on site prior to construction. Any inconsistencies to be reported to Giant immediately. If in doubt please
ask Giant for clarification. FLOOR RCP
• Any variation from these drawings requires written approval from Giant.
• This drawing has been produced to illustrate design intent. All shop drawings are to be submitted to and sanctioned by Giant prior to manufacture or B 03.05.17 PL FOR CLIENT APPROVAL scale 1:100 @ A3
project construction. Contractor to confirm structural integrity, stability and feasibility of all units/components prior to manufacture.
Design Consultants SHOP 5/ 50 HASTINGS STREET • Contractor to liaise with third party suppliers to confirm exact requirements, including electrical, data, comms & hydraulic requirements a & access points.
Ground Floor, 3 Little Collins St • Contractor to ensure consistency between similar materials is maintained.
A 10.04.17 PL FOR CLIENT APPROVAL drawn by PL checked by CW
Surry Hills NSW 2010 NOOSA HEADS • Copyright © Giant. This drawing is the property of Giant, design and copyright are reserved by them. The drawing is issued upon condition it is not copied,
reproduced, retained or disclosed to any unauthorised person either wholly or in part without the prior consent in writing of Giant. All rights reserved
T 8045 2950 E [email protected] issue date initials revision details client approval issue D
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.