: Soil Classification
i . Borehole Nos , L&2&3
Soil Category
i Indicative Drainage Poorly Drained
Structure Moderately
Texture Light Clays
i Indicative Permeability P (m/d) as Ksat* 0.06 - 0.12
Recommended DIR
i (ASINZS 1547 / 2000) PO
i 4.0 Treatment Facility:
The on site treatment facility is to be an Aerated Wastewater Treatment Sewerage System (1QEP) or equivalent. A 3900
litre Septic Tank is to be installed in front of the Envirocycle Model 10NR as shown on the site plan. A Pump Well is to
be installed and fitted with a “Feka Pump” as shown on the site plan. This design will provide an estimated EP of 14 and
i incorporate surge controls.
The owner has chosen the EnviroCycle Model 10nr Advanced Secondary, Ultraviolet Sterilisation System for this site
J due to the environmental and family health issues.
© Prior to installation a manufacturers handbook will be issued. The handbook contains vital information pertaining to the
operation and maintenance of the system, along with a list of suggested suitable plants and products which can be used
i in the system.
The handbook must be retained on the property for possible future owners.
i 5.0 Land Application Area:
There are 2 proposed Land Application Areas. The preferred method of dispersal in Land Application Area # } is
i Covered Surface Dripper Irrigation to existing fruit tree’s.
The preferred method of dispersal in Land Application Area # 2 is Surface Irrigation via 2 FIXED turf valves
with ONE heavy droplet sprinkler attached to approximately 5m of purple sullage hose.
i Under manufactures guidelines the Ultraviolet Sterilisation unit of the Envirocycle Model 10nr requires an
irrigation flow rate not exceeding 480 L/ph. The irrigation system is designed to comply with these requirements
and therefore cannot be changed. .
i In accordance with Noosa Shire stipulated guidelines, the hose and sprinkler and treated effluent must not at any
time extend beyond the approved designated area.
1@ The hose and sprinkler is to be moved within the Land Application Area #2 designated area to ensure even
distribution of water over the entire area.
Both Land Application Areas must be clearly identified by a border constructed in accordance with Noosa Shire
regulations. The area is to be bordered by earth mound, plants, fence, garden edging or other method suitable to
the owner which meets the Council guidelines.
j Two turf valves to be installed in Land Application Area #2 10m apart and each fitted with a 5m length of
lilac hose and one large droplet sprinkler on each hose.
J The proposed Land Application Area # 1 is to be maintained by the owner to ensure adequate mulch cover.
The proposed Land Application Area # 2 is to be maintained by the owner to ensure good grass cover.
i Anon return valve is to be installed in the delivery line at the tank.
A flush out valve is to be installed at the lowest point in the Land Application Area # 1.
i Two isolation valves to be installed in the delivery lines to alternate water flow to Land Application Area # 1
and Land Application Area # 2.
i Supply line to be buried 200mm and comply with AS/NZS 1547/2000.
Two warming signs are to be installed at the Jand application area.
f 3/5See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0015A4F2.001.pdfRelated documentPublic source context ↗
07/1413 - MCU - Visitor Accommodation Type 3 - Rural [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.