:                                         Soil Classification
  i    .         Borehole Nos                                            ,                         L&2&3
                 Soil Category
  i              Indicative Drainage                                                             Poorly Drained
                 Structure                                                                        Moderately
                 Texture                                                                          Light Clays
  i              Indicative Permeability P (m/d) as Ksat*                                           0.06 - 0.12
                 Recommended DIR
  i              (ASINZS 1547 / 2000)                                                 PO
  i           4.0 Treatment Facility:
              The on site treatment facility is to be an Aerated Wastewater Treatment Sewerage System (1QEP) or equivalent. A 3900
               litre Septic Tank is to be installed in front of the Envirocycle Model 10NR as shown on the site plan. A Pump Well is to
               be installed and fitted with a “Feka Pump” as shown on the site plan. This design will provide an estimated EP of 14 and
  i            incorporate surge controls.
              The owner has chosen the EnviroCycle Model 10nr Advanced Secondary, Ultraviolet Sterilisation System for this site
  J            due to the environmental and family health issues.
    ©          Prior to installation a manufacturers handbook will be issued. The handbook contains vital information pertaining to the
               operation and maintenance of the system, along with a list of suggested suitable plants and products which can be used
  i            in the system.
               The handbook must be retained on the property for possible future owners.
  i           5.0 Land Application Area:
              There are 2 proposed Land Application Areas. The preferred method of dispersal in Land Application Area # } is
  i           Covered Surface Dripper Irrigation to existing fruit tree’s.
              The preferred method of dispersal in Land Application Area # 2 is Surface Irrigation via 2 FIXED turf valves
              with ONE heavy droplet sprinkler attached to approximately 5m of purple sullage hose.
  i           Under manufactures guidelines the Ultraviolet Sterilisation unit of the Envirocycle Model 10nr requires an
               irrigation flow rate not exceeding 480 L/ph. The irrigation system is designed to comply with these requirements
              and therefore cannot be changed.                                        .
  i            In accordance with Noosa Shire stipulated guidelines, the hose and sprinkler and treated effluent must not at any
              time extend beyond the approved designated area.
1@            The hose and sprinkler is to be moved within the Land Application Area #2 designated area to ensure even
              distribution of water over the entire area.
               Both Land Application Areas must be clearly identified by a border constructed in accordance with Noosa Shire
              regulations. The area is to be bordered by earth mound, plants, fence, garden edging or other method suitable to
              the owner which meets the Council guidelines.
  j            Two turf valves to be installed in Land Application Area #2 10m apart and each fitted with a 5m length of
               lilac hose and one large droplet sprinkler on each hose.
  J            The proposed Land Application Area # 1 is to be maintained by the owner to ensure adequate mulch cover.
               The proposed Land Application Area # 2 is to be maintained by the owner to ensure good grass cover.
  i            Anon return valve is to be installed in the delivery line at the tank.
               A flush out valve is to be installed at the lowest point in the Land Application Area # 1.
  i            Two isolation valves to be installed in the delivery lines to alternate water flow to Land Application Area # 1
               and Land Application Area # 2.
  i            Supply line to be buried 200mm and comply with AS/NZS 1547/2000.
               Two warming signs are to be installed at the Jand application area.
  f                                                                                                                    3/5

Used in these records

About this file

File size
2.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

0015A4F2.001.pdf · 2.9 MB (large file)