Mens Shed Further Plans & Plumbing application
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnGenerai Specification Due to ongoing product development, the seller reserves the right to make design and engineering changes up to the time of commencing manufacture. Standards & Codes - All buildings are designed in accordance with the loads of AS/NZS 1170, AS 3600 for the concrete components, the methods of AS 4100 for steel components and the specific requirements of AS 4600 for cold formed sections. Design Criteria - Region is dependent on your geographic location, TC = Terrain Category is dependent on the surrounding terrain; Mt = Topographic Factor (1 = lowest value); Ms = Shielding Factor (1 = highest value). Refer to AS/NZS1170-2. Unless nominated, no allowance has been made for earthquake or snowloading. The building is not suitable for lining with gyprock. it is the responsibility of the purchaser to ensure that the Design Criteria nominated is suitable for the site and proposed building use. This should be obtained from a suitably qualified & insured person/company. Dimensions - all dimensions nominated are nominal sizes only. Length and width are to inside of sheeting. Height is to top of gutter. Open bays have bracing header sheets (see bracing below). If an exact opening or clearance is required, then this must be specifically nominated as “exact size” in the quotation. Environmental Characteristics - All components of the steel building are designed to suit the conditions generally described as "Non aggressive". Care must be taken with any steel building to ensure that regular maintenance is carried out. The suitable conditions and Maintenance requirements are defined in the various BlueScope Steel Technical Bulletins, Roof & Wail Sheeting - BlueScope Steel as nominated. TCT refers to Total Coated Thickness. BMT refers to Base Metal Thickness. Refer to BlueScope Steel TB-1a&1b Zincalume Steel Sections - Zincalume purlins and girts have a minimum coating of 350-gm/m2 (2350) and a minimum yield strength of 450Mpa. Refer to BlueScope Steel TB-17 Fasteners - All major connections are bolted, all other connections are tec screwed. (Some sheds are provided with bolted purlins and girts) Fasteners are supplied to a class 3 standard as defined in AS 3666. Roof screws with cyclonic washers are ONLY provided where the building is rated cyclonic. Should conditions be severe (ISO Category 4 or 5), then class 4 fasteners may be required. The purchaser should advise the seller if this is required. (Refer to BlueScope Steel TB-16 and manufacturers warranty data.) Bracing Wall & Roof: Where nominated in the engineering plans, steel strapping shall be fitted. In open bays, a double eave purlin is provided for bracing purposes. When a side is fully open, this will result in the span being reduced by 10 to 150mm on open side. Subject to engineering cross bracing in some open bays may be required. Apex; Where nominated in the engineering drawings, apex braces are supplied. Apex braces are bolted and screwed to the rafters. Droppers are provided where necessary. Knee Braces: Where nominated in the engineering drawings, knee braces are provided. Knee braces are bolted and screwed to the rafters and columns and in some instances of open bays to the columns and eave purlins. The knee braces and apex braces will reduce the internal clearance height of the building. End Wall Mullions - Where nominated are fixed at 90 degrees to the columns and inside the rafter. These reduce internal clearance. Gutters - The gutter type supplied will be nominated by our supplier as the most common type for the area. Quote # MCC1403184-5 Footings and Slab - Concrete designs provided for all soil Classes except Extreme (E) and Problem (P) soil conditions. These designs are for a safe bearing value 2100kPa. (400kPa ultimate). Where a slab is to be nominated, the wall sheeting will be supplied to extend 50mm past the slab (building height + 50mm). When footings are nominated, wall sheeting is provided to building height. Fixing Method - The fixing method nominated is for the main side columns. Other columns are supplied as per engineering design. Where chemical studs are nominated, due to hazardous transport laws, the chemical is to be supplied by others. The Engineers design may override your request. Marking, Cutting and Drilling - Most components are marked for easy identification and placement. Most are also cut to length and drilled to suit bolt placement. It will be necessary to cut and/or drill some components on site. # symbol indicates items that are only included when specifically nominated in your quotation. # Colours - Some products in some areas have a limited colour range. High Profile 0.40 TCT wall sheeting is limited in colours in some areas. # High Profile 0.40 Wall Sheeting - Only available in some areas. When not available, Low Profile sheeting will be supplied at no extra charge. # Dividing Walls - Sheeting to one side of the wall. Where the wall is in Zincalume, any doors etc. on the wall shall also be in Zincalume, # Downpipes - 100 x 75 or PVC as provided by our supplier. # Internal Stud Walls - No sheeting provided. # Access Doors - All roller doors, shutters, steel sliding or bifold doors and PA doors are NOT wind rated. Roller doors can have windlocks fitted at an additional cost. The sizes quoted are approximate door sizes - NOT clear opening sizes. Clear opening sizes may be reduced due to the building height or widths. Where doors have motors, chains or hinges fixed, these are on the left hand side (looking from the inside to out). All roller doors keys (where included) are keyed alike, unless otherwise stated. All Stable shutters will be provided in the same colour as the wall colour. Sliding doors are supplied so that each door will slide across the door bay plus one other bay as per shed layout. All doors are supplied as base rolling only. # Roller Door Transport Protection - All doors are either steel wrapped or hardboard covered to protect them during transport. Care must still be taken with Roller Doors, # Windows - Positions shown on plans are for illustration purposes only (all windows are 2.1m to top of window from floor level). Windows are to be supplied by others. A header flashing is provided as part of the building. Other stite material is provided to enable secure fixing of the windows and surrounding sheeting. * # Mezzanine Floors - Supply is for bearers and joists only. No flooring or balustrade is supplied. Combined Dead Load plus Live Load of 1.5kPa maximum. Joists spacing of 600mm. Support posts fitted under bearers in line with End Wall Mullion positions. # Skylights - Translucent Fibreglass sheeting. Industrial weight (2400 gm per m2) unless otherwise nominated. Safety mesh (if required) is to be provided by others. Maximum of one sheet per bay, per side. # Insulation + Wire - Of the type nominated in the quote. # Delivery - Delivery is quoted to within the normal delivery runs. Additional fees apply where the address is off the run. Alternatively delivery is to be ex works. Unloading is not included where any length exceeds 11.8m. Semi trailer access required. # Ex Works - collection will be from our various suppliers depots (more than 1) within the nominated city. No Compromise Steel Building Solutions
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.