Original source · versioned page text
Appendix F - Bushfire Hazard Assessment
Attached to the e-mail Applicant advises of Referral - RAL19/0008.
Bushfire Hazard Assessment v1 NCES REF: J000207 Lot 9 on RP131369 – 216 Black Mountain Road, Black Mountain Table 1 – Assessment against the Noosa Plan’s Natural Hazard Overlays Code SPECIFIC OUTCOMES PROBABLE SOLUTIONS PROPOSED SOLUTION General O10 The safety of people and property are S10.1 The proposed lots are not located on land Proposed Lot 2 is sited on land subject to Medium maintained by: that is subject to Medium or High Bushfire Hazard Potential Bushfire Intensity Area; however, the on overlay maps OM1.4-OM9.442; Local Hazard Area Map prepared as part of this a) Locating house site areas and other sensitive assessment indicates that the proposed building uses on that part of the land least affected by the OR envelope is sited within a low risk area outside of bushfire hazard; and the Potential Impact Buffer area and greater than b) fire mitigation methods are used that are S10.2 The proposed lots are sited on land 100m from the Medium Potential Bushfire adequate for the Potential Bushfire Hazard rating determined as low bushfire risk by a site-specific Intensity Area hazard. The layout is therefore of the individual site, having regard to – bushfire hazard assessment. considered compliant with O10. i. vegetation type; AND ii. slope; S10.3 Additional lots are not created where their Vehicular access to Lot 2 is proposed through the iii. aspect; only vehicular access route is through a Medium Potential Impact Buffer area via a new short length or High Bushfire Hazard area shown on overlay driveway from Black Mountain Range Road. This iv. on-site and off-site fire hazard implications of maps OM1.4-OM9.4 site-specific assessment has identified the entry the development; route traverses through a non-Bushfire Prone v. bushfire history; Area. The layout complies with S10.3 vi. conservation values of the site; and vii. ongoing maintenance. Firebreaks and fire access tracks O11 Firebreaks or fire access tracks provide— S11.1 Firebreaks are provided by— The proposed Lot 2 building envelope is sited within a low risk area outside of the Potential a) adequate access for fire fighting and other a) a cleared road reserve not less than 20m wide Impact Buffer area and greater than 100m from emergency vehicles; and located around the perimeter of the subdivision, the Medium Potential Bushfire Intensity Area between the created lots and surrounding b) adequate width to minimise the risk of fire hazard. The incorporation of fire breaks is vegetated lands; crossover. deemed unnecessary OR b) fire access tracks (may be in the form of an access easement) between the created lots and surrounding vegetated lands that— © 2018 14
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.