Council archive · source document
Attachment F - Geotechnical Report · 142007.743.04
J002100-001-L-Rev0
4 September 2023
Table 1: DCP test results
Blows per 100 mm penetration
Depth
(m, BGL)
DCP1 DCP2
0.0-0.1 1 1
0.1-0.2 2 2
0.2-0.3 3 2
0.3-0.4 2 2
0.4-0.5 3 1
0.5-0.6 3 2
0.6-0.7 3 3
0.7-0.8 3 3
0.8-0.9 4 3
0.9-1.0 4 3
1.0-1.1 3 3
1.1-1.2 4 2
1.2-1.3 5 3
1.3-1.4 5 4
1.4-1.5 5 3
1.5-1.6 7 4
1.6-1.7 6 3
1.7-1.8 6 4
1.8-1.9 5 4
1.9-2.0 6 4
2.0-2.1 5 4
2.2-2.2 7 5
2.2-2.3 7 5
2.3-2.4 8 6
2.4-2.5 - 6
2.5-2.6 - 5
2.6-2.7 - 6
2.7-2.8 - 7
2.8-2.9 - 7
Existing Structures
The existing structure on site is a single and two level duplex building comprising rendered lightweight board
cladding with a block partition wall between the units (refer Photograph 3 below).
A large manhole was noted on the adjacent lot to the south, however, NC and Unitywater records do not
indicate that either a stormwater or sewer line runs along the rear of the subject site (refer Photograph 4).
All existing nearby structures appeared to be in good structural condition, with no obvious damage visible on
the exterior that may be attributable to slope movement (e.g., no cracking in house walls or concrete
driveway).
4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment F - Geotechnical Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.