                   column 1                                             column 2




                                                                                                                    Including amendments to 3 July 2017
               Specific Outcomes                                   Probable solutions




                                                                                                        The Noosa Plan
                                                       are constructed at a level that permits the
                                                       parking area to drain from the site by gravity
                                                       means, without the need for mechanical
                                                       pumping; or
                                                       S11.5 Basements for residential uses have
                                                       flood immunity above the 1%AEP defined
                                                       flood event where alternative means to
                                                       mechanical pumping are used to achieve
                                                       such immunity; or
                                                       S11.6 Basements for non-residential uses
                                                       have flood immunity above the 1%AEP
                                                       defined flood event that may be achieved by
                                                       means of mechanical pumping where the
                                                       mechanical feature is installed with
                                                       adequate holding tanks and an alternative
                                                       back up power source.
Sloping sites
O12 On sloping sites, buildings and structures are     S12.1 Buildings are of split level design that
designed to maximise the use of natural slope and      step down the slope or have suspended
minimise the need for cut and fill.                    floor construction;
                                                       AND
                                                       S12.2 Cut or fill is less than 2m in depth
                                                       relative to natural ground surface;
                                                       AND
                                                       S12.3 The distance between the ground
                                                       and the lowest part of the floor of the
                                                       building does not exceed 3m.
Roof form
O13 Roof forms—                                        S13.1 Except for the Business Centre Zone,
a)    contribute positively to the local skyline;      the main roof of the building has a roof pitch
b)    complement the low density character of the      no less than 5 degrees and has minimum
      locality;                                        600mm eaves to at least 75% of the
c)    do not present an appearance of excessive        perimeter of the building;
      bulk to side neighbours;                         AND
d)    use simple traditional roof designs; and         S13.2 Buildings and structures do not
e)    do not create opportunities for residents to     include roof top terrace areas.
      overlook the private open space areas of
      neighbouring properties.
Landscaped setting
O14 Tall trees and native vegetation add to the        No solution provided.
character of the locality and are retained;
AND
O15 Existing character trees such as eucalypts,
poincianas, melaleucas and figs are retained.




                                               12-45
Log in to download the original file

2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB).pdf · 18.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.