Table 13.7 Categories of development and assessment for the Natural Hazards And Natural
Resources Overlays – Development Other Than Material Change Of Use
Including amendments to 3 July 2017
The Noosa Plan
Column 1 Column 2 Column 3
Type of Development Categories of development Assessment benchmarks for
35
and assessment assessable development
and requirements for
accepted development
Landslide Hazard Areas
Carrying out building work not Accepted development if the If accepted development – no
associated with a material criteria for code assessment do assessment benchmarks apply
change of use, except for a not apply
Detached house or
Community residence Code assessment if— If code assessment –
a) on land identified as Natural Hazards Overlay Code
Carrying out building work if Landslide Hazard Area
demolition or relocation of a on Overlay Maps
building, other than for a OM1.3—9.3;
Detached House or AND
Community residence or a b) involving earthworks
3
class 10 building or structure exceeding 50m (other
than the placing of
Reconfiguring a lot topsoil); or
c) involving vegetation
Carrying out operational works clearing; or
for reconfiguring a lot d) involving redirecting the
existing flow of surface
Excavation or filling of land not or ground water.
associated with a material
change of use
36
Bushfire Hazard Areas
Reconfiguring a lot Accepted development if the If accepted development – no
criteria for code assessment do assessment benchmarks apply
Carrying out operational work not apply
for reconfiguring a lot
Code assessment if increasing If code assessment –
the number of lots or Natural Hazards Overlay Code
constructing a new road within
a Bushfire Hazard Area as
shown on Overlay Maps
OM1.4 – OM9.4
35
The applicable codes identified in this table apply in addition to any applicable codes identified in a locality plan.
36
In accordance with Section 12 of the Building Regulation 2006, any building assessment work in a designated bush fire
prone area must comply with the bushfire protection provisions of BCA.