Council archive · source document
2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)
Very large file (18.9 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Table Error! No text of specified style in document.-15 Service Station
Including amendments to 3 July 2017
Column 1 column 2
The Noosa Plan
Specific Outcomes Probable solutions (if code
assessablecode assessment)
14.25 Effects of use
Siting
O76O77Service stations are located only where S77.1 The service station is located in a
they are compatible with the existing and proposed Commercial zone, on a site fronting part of
amenity and development of a neighbourhood and the major road network;
where they are appropriate given the existing or OR
likely future traffic movements in the area. S77.2 The service station is co-located with,
or adjoining, shopping facilities or
established business development.
O77O78Service stations are sited and designed for S78.1 Publicly accessible parts of the
maximum surveillance from adjacent streets and service station including the point of sale
other activities and the entrance to any external toilets are
well lit and clearly visible from areas of
activity within the site (such as petrol
pumps) as well as from adjacent uses and
the street.
O78O79The site is large enough to accommodate S79.1 The site has—
2
the service station and associated carparking, a) an area of a least 1,500m ;
accessways and landscaping. b) a frontage of at least 40m; and
c) where a corner site, a frontage of at
least 30m to each road to which the
site has frontage.
Neighbouring amenity
O79O80Service stations ensure the amenity of S80.1 Where located within 150m of a
neighbouring residential areas is protected. residential use or land included in a
residential zone—
a) buildings are constructed of non-
reflective material, including concrete,
brick or timber; and
b) a landscaped area , a minimum of 2m,
is provided along the property
boundary to any road;
AND
S80.2 Where the site adjoins a Residential
Use or land included in a residential zone—
a) a 2m high solid screen fence is
provided along the common
boundaries; and
b) hours of operation are limited to
between 7.00 am and 10.00 pm.
Site layout & design
O80O81Buildings, structures, driveways, tanks and S81.1 Fuel pumps are not less than 8m from
fuel bowsers are sited to— any frontage;
a) ensure the safe and efficient use of the site; AND
b) maintain visual amenity and streetscape S81.2 Inlets to bulk fuel storage tanks are
character; located so tankers stand wholly within the
c) provide adequate separation to adjoining land site and on level ground while discharging
uses; and fuel into tanks.
d) not cause an environmental nuisance to
neighbouring properties.
O81O82Customer air and water facilities, and any S82.1 Customer air and water facilities, and
automatic mechanical car washing facilities are any car washing facilities are setback 5m
located such that— from any residential property boundary.
a) vehicles using or waiting to use such facilities
29