                                                                   column 1                                                column 2
            Including amendments to 3 July 2017




                                                               Specific Outcomes                                 Acceptable solutions (if self
The Noosa Plan



                                                                                                      assessableaccepted development subject to
                                                                                                                         requirements)
                                                                                                       Probable solutions (if code assessablecode
                                                                                                                          assessment)
                                                  lead to opportunities for concealment and          and semi-public spaces, including entrances and
                                                  possible assault sites.                            exits to sites and buildings, by:
                                                                                                     a) planting trees which have clean trunks to a
                                                                                                          height of at least 1.8 m; and
                                                                                                     b) appropriately spacing shrubs at 1.2m
                                                                                                          horizontal centres, with a maximum height of
                                                                                                          0.75m, to avoid clumping and to retain
                                                                                                          sightlines.

                                                  O6 Street trees and plantings in towns and         S6.1 Street trees and trees in carparking areas
                                                  villages, carparks and other areas where           achieve a maximum of 900mm clear trunk height
                                                  potential conflicts with vehicles and              for a 2.0m high tree at planting and are able to
                                                  pedestrians are evident, are planted so as to      attain a clear trunk height of 1900mm on maturity;
                                                  maximise vehicle and pedestrian safety.            AND
                                                                                                     S6.2 All scrub planting to be a maximum height of
                                                                                                     700mm from the road pavement (not top of kerb).
                                                  Services and utilities
                                                  O7 All landscaping works maintain                  S7.1 Plant species used in landscaping adjacent
                                                  adequate safe distance from services and           to substations, or adjacent to or on electricity
                                                  utilities including substations, overhead          transmission line easements, are less than 4m
                                                  powerlines, power poles and transformers,          high at maturity and do not encroach within 3m of
                                                  street lamps, stormwater catchment pits, and       a substation boundary;
                                                  underground services and utilities.                OR
                                                                                                     S7.2 For trees higher than 4m, trees are planted
                                                                                                     at a distance from any part of an electricity
                                                  Figure 14-17
                                                                                                     transmission line at least equal to the expected
                                                                                                     height of the tree at maturity (see Figure 14-17);
                                                                                                     AND
                                                                                                     S7.3 For power lines that connect to a premises,
                                                                                                     the height of plant species at maturity provides for
                                                                                                     a 2m clearance below the power line; (see Figure
                                                                                                     14-18)
                                                                                                     AND
                                                                                                     S7.4 Trees and large scrubs are located a
                                                                                                     minimum of—
                                                                                                     a)    5m from electricity poles and pillars;
                                                                                                     b)    4m from street lamps;
                                                  Figure 14-18                                       c)    2m from stormwater catchment pits; and
                                                                                                     d)    2m from underground services and utilities;
                                                                                                     AND
                                                                                                     S7.5 Plants are located to enable tradespersons
                                                                                                     to access, view and inspect service meters, such
                                                                                                     as water and electricity meters;
                                                                                                     AND
                                                                                                     S7.6 Root barriers are installed around trees that
                                                                                                     are located within 3m of any infrastructures or that
                                                                                                     have potentially invasive roots.




                                                                                                    138
                                                                                              Landscaping Code

Used in these records

About this file

File size
18.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB).pdf · 18.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.