                  column 1                                          column 2
              Specific Outcomes                    Probable solutions (if code assessablecode




                                                                                                                    Including amendments to 3 July 2017
                                                                  assessment)




                                                                                                        The Noosa Plan
ease of maintenance and ease of access for
cleaning;                                          S5.1 Waste storage areas are constructed of
                                                   impermeable, durable and non-textured
AND                                                materials and surfaces so that they are easily
                                                   cleaned;
                                                   AND
                                                                                      2
                                                   S5.2 A minimum distance of 0.5m distance is
                                                   provided between and around waste storage
                                                   bins to allow for manoeuvring and washing of
                                                   bins.
O6 Waste storage areas provide a safe and          AND
secure environment for users through–
a) appropriate siting and access;                  S6.1 No solution provided.
b) the provision of lighting; and
c) restricting access to the general public by
    making the area clearly identifiable as
    private space (eg. through landscaping,
    change of paving material or fencing, rather
    than locking the area.
Water management for waste storage areas
O7 Waste storage areas are designed to             S7.1 The waste storage area —
contain and appropriately dispose of leakage       a) is bunded and graded so that washwater
from bins and wastewater from bin washing.             and bin leakage are drained to the sewer or
                                                       an on-site effluent disposal system via a
                                                       gully within the storage area;
                                                   b) has a bund wall with a maximum height of
                                                       100mm;
                                                   c) is serviced by a conveniently located
                                                       hosecock and backflow prevention device,
                                                       and connected to a water supply; and
                                                   d) is roofed or otherwise covered if the
                                                       storage area is—
                                                                                2
                                                        i)       more than 1m ; or
                                                        ii)      storing wet waste; or
                                                        iii)     storing other waste with a high
                                                                 potential to cause pollution if
                                                                 washed or leaked from the bins,
                                                                 including waste oil or putrescibles.




                                                161
                                       Waste Management Code

Used in these records

About this file

File size
18.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB).pdf · 18.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.