                                Figure 14-31




                                S9.5 For “Y” and “T” shaped jetty heads—
                                                              2
                                a)    a maximum area 10.5m excluding any
                                      walkway is provided; and
                                b)    a walkway with a minimum length of 3m is
                                      provided (Refer Figure 14-32);
                                Figure 14-32




                                S9.6 Gangways and walkways serving jetties
                                and pontoons have at least one rigid handrail
                                fitted and meet the following—
                                a) For detached houses – a minimum width of
                                      750mm and a maximum width of 1.5m;
                                b) For other residential uses –
                                      i.   the gangway for single berth pontoons
                                           has a minimum width of 900mm;
                                      ii. the gangway for multiple berth
                                           pontoons has a minimum width of
                                           1.2m if fitted with one handrail and
                                           900mm if fitted with a handrail on each
                                           side;
                                      iii. the primary walkway to multiple berth
                                           pontoons has a maximum width of
                                           1.5m; and
                                      iv. The maximum width of the gangway is
                                           1.5m;
                                AND
                                S9.7 In Noosa Sound, where quaylines are set,
                                a jetty or pontoon does not extend into the


                              165
                    Watercourses Works Code

Used in these records

About this file

File size
18.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB).pdf · 18.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.