                                                                        column 1                                           column 2
                                                                    Specific Outcomes                     Probable solutions (if code assessablecode
The Noosa Plan



                                                                                                                         assessment)




                                                                                                          Figure 14-38




                                                                                                          AND
                                                                                                          S12.8 Walkways serving jetties have at least
                                                                                                          one rigid handrail fitted and the walkway is a
                                                                                                          minimum width of 750mm and a maximum width
                                                                                                          of 1.5m where—;
                                                                                                           a) the walking surface of the jetty is
                                                                                                                 constructed level with the top of the
                                                                                                                 revetment wall;
                                                                                                           b) water reticulation systems are fitted with a
                                                                                                                 mechanical backflow prevention device;
                                                                                                                 and
                                                                                                           c) electrical reticulation systems carrying
                                                                                                                 electricity in excess of 24 volts are not to
                                                                                                                 extend beyond the revetment wall;
                                                                                                           AND
                                                                                                           S12.9 Any lower-level platform, or siding, along
                                                                                                           the jetty walkway has a maximum width of
                                                                                                           500mm and does not exceed 2m2 and does not
                                                                                                           interfere with the prolongation of boundaries as
                                                      O13 Pontoons and boat ramps are not                  indicated by Probable solutions 11.1-11.3;
                                                      constructed in Noosa Waters Estate.
                                                                                                          S13.1 No solution provided
                                                      14.169 Boat lifting devices
                                                      O14 Boat lifting devices are only constructed in    S14.1 Boat lifting devices are only located in
                                                      the absence of a boat ramp and are designed         conjunction with an approved jetty where
                                                      and located to—                                     a) the boat lifting device does not extend into
                                                      a)    ensure that unacceptable risks to personal         the watercourse beyond the end of the
                                                            and public safety are unlikely to be               approved jetty;
                                                            caused;                                       b) the boat lifting device is no greater than 4m
                                                      b)    avoid cluttering of the watercourse;               in width or for a jetty hoist 2m in width;
                                                      c)    ensure that visual amenity of the             c) the boat lifting device is located adjacent to
                                                            foreshore and watercourse is maintained;           walkway to the jetty and is generally
                                                            and                                                perpendicular to the revetment wall;
                                                      d)    ensure the structure integrity of the works   d) the boat lifting device is not located on the
                                                            are maintained and not compromised.                jetty head; and
                                                                                                          e) the outermost projection of the boatlifting
                                                                                                               device of jetty hoist is setback a minimum
                                                                                                               of 1m from the prolongation of the
                                                                                                               boundaries;

                                                                                                       170
                                                                                             Watercourses Works Code

Used in these records

About this file

File size
18.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB).pdf · 18.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.